background image

Features 

 

GFK-2291B PROFIBUS 

Slave 

Adapter 

 

11 

LEDs 

Four LEDs are located on the PROFIBUS Slave module. These 
LEDs indicate the module status and the fieldbus status. 

Not used

Off line 

Ready (on line)

Diagnostics

 

LED no. Indication Description 

Summary of Contents for IC754PBSS01

Page 1: ...QuickPanel View Communication Module Hardware User s Guide PROFIBUS Slave Adapter IC754PBSS01 April 2010 GFK 2291B...

Page 2: ...ormation contained herein does not purport to cover all details or variations in hardware or software nor to provide for every possible contingency in connection with installation operation or mainten...

Page 3: ...vider ip ge com Technical Support If you have technical problems that cannot be resolved with the information in this guide please contact us by telephone or email or on the web at www ge ip com suppo...

Page 4: ...mea ip ge com Customer Care Email customercare emea ip ge com Primary languages of support English French German Italian Czech Spanish Asia Pacific Online Technical Support www ge ip com support Phone...

Page 5: ...uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communica tions Operation of this equipment...

Page 6: ...se anti static precautions when ac cessing the mating connector or the interior of the unit 1 Disconnect the DC input power terminal block connec tor from your QuickPanel View unit before connecting t...

Page 7: ...he back of the unit Caution Be sure to properly align pins in the dual connector upon insertion to avoid damage to the card or the QuickPanel View unit 4 Install the three screws to secure the card in...

Page 8: ...Features PROFIBUS Slave Adapter GFK 2291B 8 Overview The PROFIBUS module is shown below...

Page 9: ...US Slave Adapter 9 PROFIBUS DP Connector 9 Pin in D sub female Signal Description 1 NC 2 3 B Line Positive RxD TxD 4 RTS Request to send 5 GND Bus Isolated ground 6 5V Bus Isolated 5V 7 8 A Line Negat...

Page 10: ...ng at the front of the module the leftmost switch is used for the ten setting and the rightmost switch is used for the setting of the integers Example Address Left Switch Setting x 10 Right Switch Set...

Page 11: ...PROFIBUS Slave Adapter 11 LEDs Four LEDs are located on the PROFIBUS Slave module These LEDs indicate the module status and the fieldbus status Not used Off line Ready on line Diagnostics LED no Indi...

Page 12: ...en Indicates that the module is On Line on the fieldbus Green Module is On Line and data exchange is possible Turned Off Module is not On Line Off line Red Indicates that the module is Off Line on the...

Page 13: ...ring initialization of the module is not equal to the length set during configu ration of the network Flashing Red 2 Hz Error in User Parameter data The length contents of the User Parameter data set...

Page 14: ...ol 1 2 0 Vol 2 2 0 Configuration test version A 12 Data Rate All baud rates from 9600 bps to 12 Mbps with auto baud rate detection Termination Termination required at the end of the net work cable Env...