Safety for starting applications
Consider your machine or system when determining the start conditions:
– Starting the machine or system may only take place when no persons are within the
danger zone.
– Comply with the requirements of EN ISO 13849-1 with respect to manual resetting
functions.
This applies to:
–
Switching on of safe devices.
–
Acknowledgment of device error messages.
–
Acknowledgment of communication errors.
–
Acknowledgment of block error messages in the application.
–
Removing safeguards for safety functions.
Observe your safety logic during programming/configuring:
– The change from a safe state (replacement value = 0) to the operating state can cause
an edge change (zero-one-edge).
– Include measures in your safety logic that prevent this edge from starting or restarting
of the machine/system unexpectedly.
1.5
Directives and standards
The manufacturers and operators of machines and systems, in which the IC220SDL953
module is used, are responsible for adhering to all applicable directives and legislation.
For the standards observed by the module, please refer to the certificate issued by the
approval body and the EC declaration of conformity. These documents are available on the
Internet at
www.ge-ip.com
.
1.6
Correct usage
Only use the VersaSafe system in accordance with the instructions in this section.
The IC220SDL953 safety module is designed exclusively for use in a VersaSafe system.
It can only perform its safety-related tasks within the system if it has been integrated into
the execution process correctly and in such a way as to avoid errors.
You must observe all information in this manual as well as in the documents listed in
"Documentation" on page 1-5. In particular, only use the module according to the technical
data and ambient conditions specified in Section 10, "Technical data and ordering data" on
page 10-1 and onwards.
Within a VersaSafe system, the safety module can be used to achieve safety functions with
the following requirements depending on the conditions of use:
– Up to SIL 3 according to standard EN 61508
– Up to SIL CL 3 according to standard EN 62061
– Up to Cat. 4/PL e according to standard EN ISO 13849-1
Please also refer to "Achievable safety depending on the modules used" on page A-30.