Page 45
Hydran* M2-X Instruction Manual
MA-029
Rev. 1.0,
30-Jul-18
•
Clear Short Term Hist
: To delete the content of the Short Term history file
.
•
Clear Long Term Hist
: To delete the content of the Long Term history file
.
•
Clear Event Hist
: To delete the content of the Events history file
.
2.
Press
Ok
. The message
History Cleared
is then displayed.
Clearing a history file deletes its data from the Hydran M2-X.
This data cannot be recovered. To keep the data, download it
using the Perception software before clearing the file.
3.2.6.3
Clear Sensor Hist File
Clr S.Card#1 Hist
: To delete the content of the Sensor history file.
Note: Use this function only if the sensor card is replaced.
3.2.7
Comm Setup
Note: The Hydran M2-X
’s communication parameters can only be modified using the
Hydran M2-X
’s keypad and display.
They cannot be changed using the Perception
software.
The
Comm Setup
function is used to:
•
Set the network and Hydran M2-X
’s identification number.
•
Set the communication baud rate and other communication parameters.
3.2.7.1
Identification
•
Power Station ID
: Power station’s identification number, ranging from
1 to 9999.
All
Hydran M2-X
’s belonging to a local network must share the same power
station identification number. This number is used when accessing a station
remotely or when analyzing and displaying history file data in the Perception
software. Each local network must have a different power station identification
number.
•
Monitor ID
: Hydran M2-X
’s identification number, ranging from 1 to 254. An
exclusive
identification number must be assigned to each Hydran M2-X in a local
network. If two Hydran M2-X
’s share the same number in a local network, they
will not be able to communicate properly with the Perception software. The
numbers can be assigned sequentially or using any other assignment method
preferred by the user; it can be useful to assign numbers that correspond to the
CAUTION