The Hydran 201T
i
is an intelligent, on-line monitoring system that measures the level of
combustible gases in dielectric oil for the early detection and monitoring of incipient faults
in transformers or any other oil-filled electrical equipment.
A picture of the H201T
i
can be found in Figure 1-1 on page 1-3.
2.1
FEATURES
The main features of the Hydran 201T
i
are:
• A Hydran 201 sensor that measures a composite value of the following dissolved gases
in oil: hydrogen (H
2
), carbon monoxide (CO), acetylene (C
2
H
2
) and ethylene (C
2
H
4
)
• Easy installation on a valve of the equipment to be monitored
• A six-key membrane keypad
• A backlit, alphanumeric, liquid crystal display (LCD) to use the H201T
i
without a host
computer. Provides the following on-line information:
– Level of dissolved gases in oil
– Hourly trend (gas level variation during a period of time measured in hours)
– Daily trend (gas level variation during a period of time measured in days)
– Alarm messages
• Three alarms:
– Two gas alarms (High and High-High; levels are adjustable), triggered by the gas
level, and the hourly and daily trends
– One system fail alarm, triggered by several conditions
• Four historic data files (automatic recording of data):
– Events (recording at the time of events; example: alarms)
– Short Term and Long Term (recording at fixed, adjustable logging rates)
– Service (recording at the time of the sensor tests)
• Semimonthly, automatic sensor test and state report
• Digital calibration of the analog inputs and output
• Isolated, analog 4–20 mA output
• An extremely high immunity to electrical surges, radio-frequency interferences and
electrostatic discharges
Summary of Contents for Hydran 201i
Page 1: ...GE Energy Services Digital Energy Hydran Instruction Manual 201i System ...
Page 6: ...Instruction Manual vi Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 8: ...Instruction Manual viii Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 22: ...Instruction Manual xxii Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 36: ...Chapter 1 Introduction 1 10 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 114: ...Chapter 5 Before Installation 5 16 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 143: ...Installation Part 17997 Rev 6 March 2011 6 29 Figure 6 9 Installing the CPU Module ...
Page 236: ...Chapter 12 Troubleshooting 12 20 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 244: ...Chapter 13 Maintenance 13 8 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 254: ...Appendix B Mechanical Drawings B 2 Rev 6 March 2011 Part 17997 Figure B 3 1 5 In Adaptor ...
Page 255: ...Hydran 201Ti Intelligent Transmitter Part 17997 Rev 6 March 2011 B 3 Figure B 4 1 In Adaptor ...
Page 284: ...Appendix G Unit Conversions G 2 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 298: ...Appendix I Glossary I 12 Rev 6 March 2011 Part 17997 PAGE LEFT INTENTIONALLY BLANK ...
Page 299: ......