GE GTX65GBSJWS Dimensions And Installation Information Download Page 1

GTX65GBSJ 

GE Appliances 6.1 Cu. Ft. Capacity Aluminized Alloy Drum Gas Dryer with HE Sensor Dry

For answers to your Monogram, GE Café

 Series, GE Profile

 Series or 

GE Appliances product questions, visit our website at geappliances.com 
or call GE Answer Center

®

 Service, 800.626.2000.

Specification Revised 5/16

EXHAUST OPTION

: When viewed from the front 

of the unit, exhaust 3-way via rear, left and bottom. 
Dryer is shipped exhausted to the rear. Alternate 

exhausting knockouts are supplied.

GAS:  

An individual, properly-grounded branch 

circuit, with a three-prong grounding-type receptacle, 

protected by a 15 or 20 amp circuit breaker or a time-
delay fuse is required.

GAS DRYER ELECTRIC RATING: 

120V, 60Hz, 6A

GAS (BTU/HR):

 22,000. Factory-equipped for 

natural gas. Tested for LP gas. LP gas supply requires 
a conversion kit. Check installation instructions for 
correct kit and have a qualified gas technician install a 
conversion kit. See dryer ducting information for proper 
installation.

NOTE:

 Dryer wall outlet must be located within 36" of 

service cord entry and accessible when dryer is mounted 
in position.

INSTALLATION INFORMATION:

 For complete 

information, see installation instructions packed with 
your dryer.

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

SPECIAL INSTALLATION REQUIREMENTS

ALCOVE OR CLOSET INSTALLATION:

 

-  

If your dryer is approved for installation in an alcove or closet, it will be stated on a 

label  on the dryer back.

The dryer MUST be exhausted to the outside.

-  

Minimum clearances between dryer cabinet and adjacent walls or other surfaces 
are: 0" either side; 1" front, top and rear.

-  

Closet doors must be louvered or otherwise ventilated and must contain a 
minimum of 60 sq. in. of open area equally distributed. If this closet contains 
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of 
open area equally distributed.

-  

No other fuel-burning appliance shall be installed in the same closet with a 
gas dryer.

BATHROOM OR BEDROOM INSTALLATION:

The dryer MUST be exhausted to the outdoors. 

-  

The installation must conform with the local codes, or in the absence of local 
codes, with the National Electric Code and National Fuel Gas Code, ANSI 
Z223 for gas dryers.

MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET 

INSTALLATION:

Minimum clearances to combustible surfaces are: 0" both sides; 1" rear.

DRYER EXHAUSTING INFORMATION :

 

Use metal duct only, vertical and horizontal ducting.