Page 1: ...inet and use only UL approved transition ducting between the dryer and the home duct DO NOT install a clothes dryer with flexible plastic ducting materials If flexible metal semirigid or foil type duct is installed it must be UL listed and installed in accordance with the instructions found in Connecting The Dryer To House Vent on page 5 of this manual Flexible venting materials are known to colla...
Page 2: ...ane LP gas ALL CONVERSIONS MUSTBEMADEBYPROPERLY TRAINED AND QUALIFIEDPERSONNEL AND IN ACCORDANCE WITH LOCALCODES AND ORDINANCE REQUIREMENTS The dryer must be disconnected from the gas supply piping system during any pressure testing of that sys tem at a test pressure in excess of 0 5 PSI 3 4 KPa The dryer must be isolated from the gas supply piping system by closing the equipment shut off valve du...
Page 3: ...se odoptors os shown Connector nuts must not be connected directly to pipe threads APPLYPIPECOMPOUND TO THEADAPTER AND DRYER GASINLET Tighten the flexible gas line using two adjustable wrenches I APPLYPIPECOMPOUND TO ALL MALETHREADS Tighten oil connections using two adjustable wrenches Do not overtorque gas connections 14 LEAK TEST _ZL WARNING NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS OPEN GAS...
Page 4: ... Increase the drying times and the energy cost Reduce the dryer life Accumulate lint creating a potential fire hazard The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not covered by the warrantg Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct The MA IMUM ALLOWABLE duct length and number o...
Page 5: ...ates a potential fire hazard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct These fasteners can accumulate lint creating a pot...
Page 6: ...t with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap the exhaust pipe Cut off and remove excess duct Keep the duct as straight as possible for maximum airflow 4 Secure the duct to the exhaust pipe with the other clamp ELBOW HIGHLY RECOMMENDED _WS HIGHLY RECOMMENDE_ DO EXCESSIVE EXHAUST LENGTH LEVELING DRYER LEVEL FRONT TO BACK LEVE...
Page 7: ...ET ZiWARNING BEFORE PERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY PROTECT YOUR HANDS AND ARMS FROM SHARP EDGES WHEN WORKING INSIDE THE CABINET BE SURE TO WEAR GLOVES REMOVE SCREW AND SAVE _ REMOVEBOTFOM KNOCKOUT Detach and remove the bottom knockout Remove the screw inside the dryer exhaust duct and save Pullthe duct out of the dryer Protect sharp ...
Page 8: ...ervice provider Place dryer in final locution _WARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE KIT WEIM454 CHANGING DIRECTION OF DOOR OPENING REMOVE 4 HOLE PLUGS AND REMOVE 4 PLACE THEM INTHE HOLES HINGE SCREWS ON THE OPPOSITE SIDE ROTATE DOOR 180 AND REINSTALL i_ISERVICING _kWARN ING LABEL ALL WIRES PRIOR TO DISCONNECTING WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGERO...