background image

21

Care and cleaning of the water softening system.

GEAppliances.com

Brine (salt dissolved in water) is needed for each
and every recharge. The water for making brine
is metered into the salt storage area by the
water softening system valve and control.

However, you must keep the tank supplied 
with salt.

When to refill with salt:

If the blue indicator light

and 

DAYS TO EMPTY

are flashing, there is less

than 15 days supply of salt. Refill with salt. In
humid areas it is best to refill with less salt and
more often, to avoid the forming of a salt bridge
(see page 16). After adding salt, remember to
reset the 

SALT LEVEL

in the control (see page 11).

Never allow the salt level to drop below zero on
the yellow indicator before you refill it. Without
enough salt, you will soon have hard water.

Use clean water softening salts only, at least
99.5% pure. NUGGET, PELLET or coarse SOLAR
salts are recommended. 

Do not use rock, block,

granulated or ice cream making salts.

They

contain dirt and sediments, or mush and cake,
and will create maintenance problems.

CAUTION: 

Water softening salt

with iron removing additives:

Some salts

may have an additive to help the water
softening system handle iron in the water
supply. Although this additive may help to
keep the water softening system resin clean,
it may also release corrosive fumes that
weaken and shorten the life of some water
softening system parts. GE recommends
using only Diamond Crystal

®

Red•Out

®

brand salt.

Checking the Salt Storage Level and Refilling

Your water softening system takes hardness
minerals (calcium and magnesium) out of 
the water. Also, it can control some (see the

Specification Guidelines

section) “clear water”

iron. With clear water iron, water from a faucet 
is clear when first put into a glass. After 15 to 30
minutes, the water begins to cloud or turn rust
colored. A water softening system 

will not

remove any iron that makes the water cloudy 
or rusty as it comes from the faucet (called red
water iron). To take red water iron out of water, 
or over the maximum of clear water iron, 
an iron filter or other equipment is needed.

GE recommends using only Diamond Crystal

®

Red•Out

®

brand salts with Iron Fighter

®

additive

to help keep the resin bed clean of clear iron. If
your water supply has clear water iron, periodic
resin bed cleaning is needed. GE recommends
using Super Iron Out

®

brand resin bed cleaner 

to thoroughly clean your resin bed if your iron
content is high. Clean the bed at least every six
months, or more often if iron appears in the soft
water between cleanings.

IMPORTANT:

It is important to mix the resin bed

cleaner with water (following the manufacturer’s
instructions), pour it into the

brinewell tube

(see page 5) and recharge the softener
immediately. Do not pour the resin bed cleaner 
in with the salt, as it will not be as effective in
cleaning the resin, and can cause damage to 
the softener if it is left in the brine tank for an
extended period due to the corrosive gases 
that are formed.

Cleaning Iron Out of the Water Softening System

Summary of Contents for GNSH45E

Page 1: ...5 49 50180 4 03 09 JR Write the model and serial numbers here Model ________________ Serial ________________ To find these numbers lift the cover and look on the rim below the control panel Models GXS...

Page 2: ...OPER INSTALLATION Install or store where it will not be exposed to temperatures below freezing or exposed to any type of weather Water freezing in the system will break it Do not attempt to treat wate...

Page 3: ...ximum allowable inlet water pressure is 125 psi If daytime pressure is over 80 psi nighttime pressure may exceed the maximum Use a pressure reducing valve if necessary Adding a pressure reducing valve...

Page 4: ...an be ordered from GE Parts at 800 626 2002 part number WS07X10004 If a rigid valve drain is needed to comply with plumbing codes you can buy the parts needed to connect a 1 2 copper tubing or plastic...

Page 5: ...e cover SALT GOES HERE Brinewell O rings 2 1 NPT male adapter 2 Clips 2 1 female adapter 2 not supplied Clips O rings 2 INLET Hard water to outside faucets Fig 1 CROSSOVER Use if water supply flows fr...

Page 6: ...gas or electric supply to the water heater in the possibility that the water heater may be drained while draining pipes Turn off the water supply to pipes to be cut and drain the house water pipes Op...

Page 7: ...NPT adapters snap into place Pull on the bypass valve and NPT adapters to make sure the parts are held securely in place 4 Installation Instructions 7 IN OUT Turn bypass valve upside down to connect t...

Page 8: ...NDPIPE Blue indicator light Clip 1 4 NPT thread 1 2 outside diameter copper tube not provided Compression fitting 1 4 NPT x 1 2 O D tube not provided Cut barbs from valve drain elbow pull clip and rem...

Page 9: ...run for several more minutes or until clear Close all water faucets Check your plumbing work for leaks and fix right away if any are found Be sure to observe previous caution notes Turn on the gas or...

Page 10: ...the correct model A beep sounds while pressing buttons for control programming One beep signals a change in the control display Repeated beeps mean the control will not accept a change from the butto...

Page 11: ...of brine well inside brine tank see illustration on page 5 3 Press UP or DOWN button to set the SALT LEVEL to correspond to level on yellow indicator in brine tank NOTE Each press of a button changes...

Page 12: ...normal run display FEATURE OTHER DATA DISPLAYS These models have an option to have the run display indicate different information The information displayed on the top half of the display can be chang...

Page 13: ...ay will flash Err and the alarm will beep every 30 seconds from 8 00 AM to 8 00 PM to signal that the softener requires service The alarm can be turned off by pressing any button but the blue indicato...

Page 14: ...RTANT Press and hold for 3 seconds the faceplate RECHARGE button to start an immediate recharge RECHARGE begins to flash in the display The bleach will be drawn through the water softener and out the...

Page 15: ...ter will fill with the hard water Automatic Hard Water Bypass During Recharge Fill Salt dissolved in water is called brine Brine is needed to clean the hard minerals from resin beads To make the brine...

Page 16: ...esin tank during recharge If it becomes plugged with sand dirt etc the water softening system will not work and you will get hard water To get to the nozzle and venturi remove the water softening syst...

Page 17: ...tem begins an immediate recharge and when over in about two hours you will have a new supply of soft water Once started you cannot cancel this recharge Feature Optional Recharge Controls Feature Memor...

Page 18: ...ervice If you are not getting soft water and an error code is not displayed use the procedures below to find the problem First make the following visual checks VISUAL CHECKS 1 Is there electrical powe...

Page 19: ...lve and disconnect bypass valve from body Check turbine for binding or restriction due to debris If this does not correct the problem the Timer Sensor or Turbine may require replacement 4 Historical d...

Page 20: ...contacting salt See Care and cleaning of the water softening system section If the water softening system does not draw brine check nozzle and or venturi dirty or defective defective nozzle and ventu...

Page 21: ...ng only Diamond Crystal Red Out brand salt Checking the Salt Storage Level and Refilling Your water softening system takes hardness minerals calcium and magnesium out of the water Also it can control...

Page 22: ...lectrical outlet on a circuit that can NOTE The electrical outlet for the softener should be continuously be switched off live so it cannot be accidentally switched off Manual bypass valve in bypass p...

Page 23: ...ater Softener System section page 16 Water is blue color Acidic water in copper plumbing Have the water tested at once after water softening system was installed Water softening system Meter turbine s...

Page 24: ...normal into a drain during recharge Water has air bubbles Air in system after installation Will go away after it runs for a while and is cloudy Error Code on control Wiring may have worked loose See p...

Page 25: ...25 Notes...

Page 26: ...26 Notes...

Page 27: ...3 3 3 7 8 9 10 11 12 56 55 17 18 19 20 21 22 38 23 24 25 26 27 28 29 30 31 32 33 34 35 36 4 55 56 999 2 39 5 6 27 Parts list GEAppliances com...

Page 28: ...135 106 105 103 101 151 110 145 143 110 147 148 138 139 141 140 120 118 117 115 116 114 113 112 111 110 109 124 125 108 123 122 146 150 119 121 107 130 132 25 cross section view seal wear strip 28 Par...

Page 29: ...0007 RIM 1 1 0020 WS31X10024 COVER BRINEWELL W DECAL 1 1 0021 WS02X10009 NUT 1 1 0022 WS32X10017 BRINEWELL W DECAL 1 1 0023 WS02X10027 SCREW 1 1 0024 WS32X10016 TANK BRINE ROUND 1 1 0025 WS18X10003 CL...

Page 30: ...3X10020 SPRING 1 1 0123 WS22X10029 PLUG DRAIN SEAL 1 1 0124 WS15X10027 NOZZLE VENTURI ASM 1 0124 WS15X10036 NOZZLE VENTURI ASM 1 0125 WS03X10043 WAVE SPRING BEARING 1 1 0130 WS35X10020 SEAL KIT 1 1 1...

Page 31: ...amage caused by possible defects with this appliance its installation or repair Product not accessible to provide required service This warranty is extended to the original purchaser and any succeedin...

Page 32: ...ated service costs original purchase Service trips to your home to teach you how to use the product Improper installation delivery or maintenance Failure of the product if it is abused misused altered...

Page 33: ...ciones 50 Servicio 47 51 53 Sistema de descalcificaci n de agua 47 53 Cuidado y limpieza 54 Consejos para la soluci n de aver as 55 57 Soporte al cliente Garant a 62 Lista de partes cat logo 58 61 Sop...

Page 34: ...no quede expuesto a temperaturas por debajo del punto de congelaci n ni est expuesto a ning n tipo de inclemencias atmosf ricas Si el agua llega a congelarse dentro del sistema ste podr a romperse No...

Page 35: ...rastre ni lo apoye en protuberancias La presi n de entrada m xima permitida es de 125 psi Si la presi n durante el d a es por encima de 80 psi la presi n nocturna podr a exceder el m ximo Use una v lv...

Page 36: ...do al 800 626 2002 no de parte WS07X10004 Si necesita una v lvula r gida de drenaje para cumplir con los c digos de plomer a podr comprar las partes necesarias para conectar un drenaje de tuber a de c...

Page 37: ...m 2 Clips 2 Clips Aros t ricos 2 ENTRADA Fig 1 V A DE ENLACE sela si el flujo de suministro fluye desde la izquierda Incluya una derivaci n sencilla o de 3 v lvulas Agua dura Agua descalcificada Hacia...

Page 38: ...entador de agua en la posibilidad de que el calentador pueda drenarse mientras usted drena las tuber as Desconecte el suministro de agua hacia los tubos que han de ser cortados y drene las tuber as de...

Page 39: ...lvula de bypass y los adaptadores NPT para verificar que las piezas se mantienen seguras en su lugar 4 Instrucciones de instalaci n 39 ENTRADA SALIDA Gire la v lvula de bypass boca arriba para conecta...

Page 40: ...2 1 27 cm de di metro externo no incluido Tubo accesorio de compresi n con rosca NPT de 1 4 0 63 cm x 1 2 1 27 cm de di metro externo no incluido Corte las entalladuras del codo de drenaje de la v lv...

Page 41: ...a o tiene un sabor salado permita que el sistema funcione por unos minutos m s o hasta que se aclare Cierre todos los grifos de agua Inspeccione en b squeda de fugas en la tuber a que se acaba de llev...

Page 42: ...bot n DOWN Luego oprima el bot n MODE modo para aceptar el modelo correcto Un bip sonar mientras usted oprime los botones para la programaci n del control Un bip significa un cambio en la pantalla de...

Page 43: ...ro del tanque de salmuera vea la ilustraci n de la p gina 37 3 Presione el bot n UP o DOWN para fijar el SALT LEVEL nivel de sal que corresponda al nivel en el indicador amarillo en el tanque de salmu...

Page 44: ...talles Presione el bot n MODE modo para regresar a la visualizaci n de corrida normal CARACTER STICA OTRAS VISUALIZACIONES DE DATOS Estos modelos tienen una opci n para mostrar en la pantalla informac...

Page 45: ...a azul se enciende 4 veces cada segundo de forma intermitente la pantalla muestra Err y la alarma suena cada 30 segundos desde las 8 00 AM hasta las 8 00 PM para se alar que el descalcificador necesit...

Page 46: ...comenzar una recarga inmediata El indicador de RECHARGE recarga aparece intermitente en la pantalla El cloro es llevado a trav s del descalcificador de agua Este proceso dura aproximadamente 2 horas 4...

Page 47: ...ura durante la recarga Llenado La sal disuelta en agua es llamada salmuera La salmuera es necesaria para limpiar los minerales duros de las diminutas part culas de resina Para formar la salmuera el ag...

Page 48: ...formaci n de un puente de sal La sal debe estar floja desde arriba hasta el fondo del tanque Tome un palo de escoba o algo parecido y con cuidado emp jelo hacia el interior del dep sito de sal introd...

Page 49: ...cesario use un cepillo peque o para remover el hierro o la suciedad Tambi n inspeccione y limpie la junta NOTA Algunos modelos tienen un peque o tap n de flujo localizado en la boquilla y el Venturi y...

Page 50: ...gua comienza una recarga inmediata y cuando termine en unas dos horas usted tendr un nuevo suministro de agua descalcificada Una vez haya iniciado usted no puede cancelar la recarga Funci n Controles...

Page 51: ...to para encontrar la fuente del problema Primero realice las siguientes inspecciones visuales INSPECCIONES VISUALES 1 Hay energ a el ctrica entrando hacia el tomacorriente en el cual el transformador...

Page 52: ...pite por cada gal n de agua que pasar por el metro El control produce un sonido por cada gal n Si no hay lectura en la pantalla con el grifo abierto revise el sensor Hale el sensor del puerto de salid...

Page 53: ...el bot n RECHARGE recarga para llevar al sistema de descalcificaci n de agua al proceso de salado Un flujo lento de agua hacia el drenaje debe comenzar Verifique la extracci n de la salmuera del tanqu...

Page 54: ...l Red Out Inspeccione el nivel de almacenamiento de la sal y el rellenado Su sistema de descalcificaci n de agua toma la dureza de los materiales calcio y magnesio y la extrae del agua Tambi n puede c...

Page 55: ...corriente est en un circuito que descalcificador debe estar permanentemente conectado para que no no puede ser desconectado pueda ser desconectado accidentalmente La v lvula de bypass manual est en Ce...

Page 56: ...o descalificada descalcificaci n de agua El sistema de El sistema de descalcificaci n de No usa tanta sal para regenerarse es muy eficiente descalcificaci n de agua agua es una unidad de demanda no es...

Page 57: ...impie y reconecte la manguera Revise en busca de giros en la l nea de drenaje Agua de color La unidad estuvo inoperante Complete los Procedimientos de desinfecci n de la p gina 46 caf amarillo por un...

Page 58: ...3 3 3 7 8 9 10 11 12 56 55 17 18 19 20 21 22 38 23 24 25 26 27 28 29 30 31 32 33 34 35 36 4 55 56 999 2 39 5 6 Lista de partes 58...

Page 59: ...135 106 105 103 101 151 110 145 143 110 147 148 138 139 141 140 120 118 117 115 116 114 113 112 111 110 109 124 125 108 123 122 146 150 119 121 107 130 132 25 cross section view seal wear strip GEAppl...

Page 60: ...009 TUERCA 1 1 0022 WS32X10017 TANQUE DEL DEP SITO DE LA 1 1 SALMUERA CON ETIQUETA 0023 WS02X10027 TORNILLO 1 1 0024 WS32X10016 TANQUE DEL DEP SITO DE LA 1 1 SALMUERA REDONDO 0025 WS18X10003 ABRAZADER...

Page 61: ...0122 WS03X10020 RESORTE 1 1 0123 WS22X10029 TAP N SELLO DEL DRENAJE 1 1 0124 WS15X10027 BOQUILLA VENTURI ASM 1 0124 WS15X10036 BOQUILLA VENTURI ASM 1 0125 WS03X10043 RODAMIENTO DE RESORTE 1 1 DE ONDA...

Page 62: ...causada por defectos posibles de este electrodom stico su instalaci n o reparaci n Producto no accesible para facilitar el servicio requerido Lo que no est cubierto Esta garant a se extiende al compr...

Page 63: ...o o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estar a n ah cuando su garant a termine Piezas y accesorios GEAppliances com Aquellos individuos con la calificac...

Page 64: ...in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories GEApplia...

Reviews: