Page 1: ...uture reference Skill Level Installation of this dishwasher requires basic mechanical electrical and plumbing skills Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the GE Appliance Warrantg See warranty information Completion Time 1 to 3 Hours New installations require more time than replacement installations If you rece...
Page 2: ...nt kit if countertop is granite or similar materiel Materials Needed for New Installations Air gap for drain hose if required Waste tee for house plumbing if applicable Electrical cable or power cord Screw tgpe hose clamps Strain relief for electrical connection Hand shut off valve recommended Water line 3 8 minimum copper tubing GPFIOL drain hose 10 Iongl if needed Air Gap 90 Elbow Hand Ferrule a...
Page 3: ...r Door Opening 2 Minimum DRAIN REQUIREMENTS o Follow local codes and ordinances Do not exceed i0 distance to drain NOTE Air gap must be used if waste tee or disposer connection is Jess than 18 above floor to prevent siphoning DETERMINE DRAIN METHOD The type of drain installation depends on the following questions Do local codes or ordinances require on air gap Is waste tee less than 18 above floor...
Page 4: ...al codes and ordinances kWARNING The improper connection of the equipment grounding conductor can resuR in a risk of electric shock Check with a qualified electrician or service representative if gou ore in doubt that the appliance is propertg grounded ADVERTENCIA Laconexi6n inadecuada del conductor de conexi6n a tierra del equipamiento puede provocar un riesgo de descarga eI6ctrica Consultea un e...
Page 5: ...From Cabinet Cabinet Face Figure F Water Line Connection Turn off the water supply Install a hand shut off valve in an accessible location such as under the sink Optional but strongkj recommended and mag be required bg local codes 1 Water connection is on the left side of the dishwasher Install the hot water inlet line using no less than 3 8 copper tubing Route the line as shown in Figure Fand ext...
Page 6: ...tion and does not rise flom the full open position o if necessarg increase or decrease tension as shown Latch door and adjust both springs to the same tension setting to correct balance STEP 3 REMOVE WOOD BASE INSTALL LEVELING LEGS IMPORTANT Do notkick offwood base Damage will occur Hove the dishwasher close to the installation location and lay it on its back Remove the four leveling legs on the u...
Page 7: ...ositionthe end of the elbow to face the rear of the dishwashe_ Front of Dishwasher Weter Valve Bracket Thread Seal Tope Figure K STEP 7 INSTALL DRAIN HOSE TO PUMP OUTLET Skip this step if drain hose has been preinstalled tn this step gou will needthe drain hose and clamp set aside in Step 1 Stand dishwasher upright Place drain hose clamp over 1 3 16 diameter end of drain hose Positionclamp so scre...
Page 8: ...ng when the dishwasher extends about 6 inches forward of adjacent cabinets Hake sure drain hose is not kinked under or behind the dishwasher Hake certain the house wiring drain tine and water tine do not inLerferewith components under dishwasher Maximum Drain Hose Length t0 Insulatior Blanket Hose i House Wiring Power Cord If Used Figure N Tip Prevent unnecessarg service call charges for no fill d...
Page 9: ...e or push on the center of the panel If SOU do damage to the panel will iikelg result The dishwasher is in the final position when the edges of the front panel are flush with the adjacent cabinets and the dishwasher is centered in the cabinet opening IM PORTANT Before opening thedishwasher door be certain the edges of the dishwasher door panel are behind the face of the adjacent cabinet and not up...
Page 10: ...ontrol panel damage Dishwasher must be positioned so the flont panel and control panel do not contact the adjacent cabinets or countertop Mounting screws must be driven straight and flush Protruding screw heads could scratch the door panel or control paneland interfere with door operation Method 1 Secure dishwasher to underside of wood countertop_ Recheck alignment of the dishwasher in the cabinet...
Page 11: ... for a total of 120 t0 feet to the foctorgdnstalled hose Use5 8 or 7 8 inside diameter hose end a coupler to connect the two hose ends Secure the _ connection with hose clamps Coupler Figure Hose Clamp Hose Clamp NOTE TOTAL DRAIN HOSE LENGTH MUST NOT EXCEED 10 FEET FORPROPER DRAIN OPERATION Connect drain line to air gap waste tee or disposer using the previousig determined method Secure hose with ...
Page 12: ...Note Check That Harness LeadsAreThreaded Thru _Ground SmallHob inBracket Open door and remove all foam and paper packaging Locate the Owner s Manual set aside in Step 1 Readthe Owner s Manual for operating instructions Check door opening and closing If door does not open and close freelg check for proper routing of spring cable over pulleg If door drops or closes when released adjust spring tensio...
Page 13: ...und turn off power at the breaker and correct plumbing us necessary Restore power after corrections are made SeeSteps 7 and 17 Open dishwasher door and make sure most of the water has drained tf not check that disposer plug has been removed and or air gap is not plugged Also check drain hose to be sure it is not kinked underneath or behind dishwasher SeeStep 17 PressStart Reset pad once again and ...
Page 14: ...Notes 14 ...
Page 15: ...Notes 13 ...
Page 16: ...SPECIFICATIONS SUBJECTTO CHANGE WITHOUT NOTICE GE Consumer Industrial General Electdc Compang Louisville Kentuckg 40225 GEAppliances com 2009 General Electric CompanLj ...
Page 17: ...ne installation inad6quate n est pas couverte par le gerentie de GEeReportez vous 6 la garentie du produit Dur6e de I installation Entre 1 et 3 heures L instalfation d un nouveau lave voisselIe exige plus de temps que le remplacement d un ancien module IMPORTANT Le lave voisselle DOlT6tre install6 de mani6re 6 ce quil puisse resorti de son empIacement si des r6parations sent n6cessaires Sile lave ...
Page 18: ...mentotion Colliers 6 vis sans fin 8ogue anti traction pour le roccordement _lectrique Robinet d arr_t recommand l Conduite d alimentation en eeu tugau en cuivre dau mains 9 5 mm 318po I 1 Bogau de videnge GPF10L 3m 10 pi de long si n6cesseire coude de 90 bague et 6crou compression Ensemble de supports de montage lot_roux certoins mod_lesl vis Phillipsn_8 6 t_te _ U creusede9 s mm Supports 13 8pal ...
Page 19: ...codes ocauxenvigueur Lebogaudevidange doit avoir uneiongueurmaximalede 3 m_tres110 pieds REMARQUE IIlout installerunecoupureanti refoutementsi Ie raccordau brogeur6 d6chetsou au raccordenTse trouve6 mains de46 cm 18po au dessusdu ptancherafin d_viter unsiphonage CHOIX DE LA MI_THODE DE VIDANGE Letype d instal ationdevidange d6penddesconditionssuivontes D Lesordonnoncesou codestocau envigueurexigen...
Page 20: ...T Un bronchement inad6quat du conducteur de raise 6 la terre peat pr6senter des risques de choc 61ectrique Sivous n6tes pas certain que l appareil est cotrectement mis 6 la terre consultez un r6parateur ou un 61ectricien qualifi6 1 Autreemplacement z I possible pourla t x t prise decourant i 0_ tll l_i_ jpfiSTdell 118po aurora t_ _11 l i 11 15cm 6po tScm I j 6cml3po desarmoires u Figure Blanc Dart...
Page 21: ... cm 2 po du plancher Figure F Raccordement de la conduite d eau chaude Coupezl olimentotion en eau o tnstmtlezun robinet d urr_t 6 un endroit accessible par e emplesous l 6vie Cette installation est fmcultative mmisfortement recommand6e et peut m me tre exig e par les codes locau en vigueud Leraccordement de le conduite d eau s effectuedu c6t6 gauche du lave vaissetle Insta lez la conduite d eou c...
Page 22: ...ltez la porte et r6gfez ies ressorts de mani_re 6 obtenir un _quilibre appropd6 I_TAPE3 ENLEVEMENT DE LA BASE DE BOIS INSTALLATION DES PIEDS DE NIVELLEMENT IMPORTANT Ne frappez pas sur Io bose de bois pour I enlever Vous endommogerez oinsi t appareil Amenez le lave vaisselle 6 proximit6 de son emplacement d6finitif et couchez le sur le dos Enlevezles quatre pieds de nive tement sous la base de boi...
Page 23: ...ord de l 61ectrovanne de90 pourroit se cosser Tournez extr_mit_ du coude pour quil pointe vers I orri_redu lave voisselle Devant du lave vaisselle _lectrovanne ude lissage Rubon pourjoints filet s Figure K 15TAPE7 RACCORDEMENT DU BOYAU DE VIDANGE LA SORTIE DE LA POMPE Sautez cette tapesile bogau de vidange a t install 6 l usine Au cours de cette _tape vous ourez besoin du bayou de vidonge et du co...
Page 24: ...Vous pourriez endommager I appareil Soisissezle panneou avont de I appareil par les c6t_s et fuites glisser le Iove vaisselle dans l ouverture de quelques centim_tres ou pouces _ la fois Figure O otre genou Vous risquezd endommoger le ponneau de porte Tirezsur lebogau devidange et le cordon d alimentation s il g o lieu par lostrous des armoires adjocentes ou fur et 5 mesure Arr_tez lorsque lelave ...
Page 25: ...voisselle est 6 son emplacement d_finitif Iorsque les bards du panneou event sent 6 6gatit6 avec los ormoires adjacentes et qua le Iove vaisselle est bien centr6 dens t ouverture IM PORTANT Avont d ouvrir la porte du Iove vaisselle assurez vous que les bards du panneau de porte du lave vaissetle sent en retrait par rapport au devont des armoires odjocentes et non pos oppug_s centre le devant des a...
Page 26: ...r ou aux c6t6s des or moires Lorsque le dessous du comptoir est en bois utitisez la m_thode n Lorsque le dessous du comptair est fobriqu_ 6 I aide dun mat_riou qui n occepte pas Ies vis 6 bois par exemple en granite utilisez la m_thode n o2 IMPORTANT po rviter tout dommage au ponneau de ta porte et au tableau de commando i four qua telave vaissellesalt install6 de mani6re qua le panneau avont et l...
Page 27: ...ongmaisn avez pasachet6lebogaudevidangeGPF10Lojoutezau bogaude vidangeinstall_6 I usineuneIongueurmaximaledei06 cm 42po pourunetongueurtotalede 3m6tres 120po Pource fake utilisez un botjau dont fediam_treint6rieurestde 15 8mm 5 8po oude 21 7mm 7 8 po et un raccordpour relier l extr6mit6 des deux bogaux Fixez le raccord raide de colliers Coltier Roccord Figure X Collier REMAROUE POURUNEVIDANGEADI_O...
Page 28: ...t de I appareil V6rifiez l ouverture et la fermeture de la porte Silo porte nouvre pas et ne se ferme pas librement v_rifiez si le c_ble du ressort est install_ sur le poulie Si Io porte s ouvre compl_tement ou se ferme lorsque vous la reDchez r6glez Io tension du ressort Reportezwous 6 l _tape 2 Assurez vous que le c6btage _lectrique est bien plac6 sous le lave vaisselle qull n est pas coinc6 ou ...
Page 29: ... et corrigez le probi_me de p omberie ou besoin R6teblissez le courant apr_s avoir colmat_ Io fuite Reportez vous aux 6topes 7 et 7 Ouvrez la porte du lave voisselle et assurez vous que Io majeure pattie de l eau o 6t6 vidang6e Si lappareit ne s est pos vid ossurez vous que le bouchon de vidange du brogeur _ d_chets a _t6 enlev_ et ou que la coupure anti refoulement est exempte de d6bris V6rifiez ...
Page 30: ...Notes 14 ...
Page 31: ...Notes IS ...
Page 32: ...LESSPECIFICATIONS PEUVENT ETREHOD_FtEESSANS PRI_AVIS GEConsumer _ndustrial General Electric Compang Louisville Kentuckg 40225 wwwetectromenogersge ca 2009 General Eiec ric Compang ...