ix
Safety and Regulatory Information
Warnings
!
Warning:
Before using the device, read through this entire manual. Attempting to
use this device without a thorough understanding of its operation may result in
patient and user injury.
!
Warning:
This device should only be operated by clinically trained personnel
familiar with the risks and benefits of this type of device.
!
Warning:
Use of this device is restricted to one patient at a time.
!
Warning:
Complete the service checkout procedure section of this manual before
putting the device into operation. If the equipment fails any portion of the checkout
procedure it must be removed from use and repaired.
!
Warning:
Do not perform the service checkout procedure while the patient
occupies the device.
!
Warning:
Do not use the device in the presence of flammable anesthetics; an
explosion hazard exists under these conditions.
!
Warning:
Do not place the device in extreme environmental conditions such as a
high ambient air flow environment or high or low temperature. This may affect the
thermal balance of the patient.
!
Warning:
Do not use this device if the system failure alarm is activated. Remove
the device from service and contact authorized service personnel for repair.
!
Warning:
In the event of loss of mains power, check all parameters upon power
restoration.
!
Warning:
Carefully route patient cabling to reduce the possibility of patient
entanglement or strangulation.
!
Warning:
Do not lean against the side of the device. The pressure may cause the
device to tip over.
!
Warning:
Do not connect to a power strip or another unapproved piece of
equipment. This may result in power failure or a reduced level of safety.
!
Warning:
Do not connect unapproved equipment into the accessory outlets.
Summary of Contents for Giraffe OmniBed Carestation CS1
Page 4: ...RH 2 Service Manual ...
Page 24: ...Service Language Disclaimer viii Service Manual ...
Page 40: ...Safety and Regulatory Information User Responsibility xxiv Service Manual ...
Page 44: ...Chapter 1 Functional Description Control Board 1 2 Service Manual FIGURE 1 1 Block Diagram ...
Page 74: ...Chapter 3 Calibration and Maintenance Line Voltage Calibration 3 12 Service Manual ...
Page 82: ...Chapter 4 Understanding the Service Interface Upgrade 4 8 Service Manual ...
Page 110: ...Chapter 5 Troubleshooting Diagnostic Readings 5 28 Service Manual ...
Page 211: ...Chapter 7 Repair Procedures Display Harness Connections Service Manual 7 75 ...
Page 212: ...Chapter 7 Repair Procedures Display Harness Connections 7 76 Service Manual ...
Page 294: ...Chapter 8 Illustrated Parts Wiring Diagrams 8 82 Service Manual ...
Page 296: ...Appendix A Compartment and Skin Probe Characteristics A 2 Service Manual ...
Page 304: ...Appendix C RS 232 Serial Data Nurse Call C 4 Service Manual ...