Page 1: ...er with flexible plastic ducting materials If flexible metal semirigid or foil type duct is installed it must be UL listed and installed in accordance with the instrt tions found in Connecting The Dryer To House Vent on page 5 of this manual Flexff _venting materials are known to collapse be easily crushed and trap lint These conditions will obstruct dryer airflow and increase the risk of fire Do ...

Page 2: ...e LP gas ALL CONVERSIONS MUSTBEMADEBYPROPERLY TRAINED AND QUALIFIEDPERSONNEL AND IN ACCORDANCE WITH LOCALCODES AND ORDINANCE REQUIREMENTS The dryer must be disconnected from the gas supply piping system during any pressure testing of that sys tem at a test pressure in excess of 0 5 PSI 3 4 KPa The dryer must be isolated from the gas supply piping system by closing the equipment shut off valve duri...

Page 3: ...d sealant CAUTION Use odoptors osshown Connector nuts must not be connected directly to pipe threods APPLYPIPECOMPOUND TO THEADAPTER AND DRYER GASINLET Tighten the flexible gas line using two adjustable wrenches I APPLYPIPECOMPOUND TO ALL MALETHREADS Tighten oil connections using two odjustoble wrenches Do not overtorque ges connections 4 LEAK TEST FLAME TO TEST FOR GAS LEAKS OPEN GAS VALVE Check ...

Page 4: ...he drying times and the energy cost Reduce the dryer life Accumulate lint creating a potential fire hazard The correct exhaust installation is YOUR RESPONSIBILITY Problems due to incorrect installation are not covered by the warranty Remove and discard existing plastic or metal foil transition duct and replace with UL listed transition duct The MAXIMUM ALLOWABLE duct length and number of bends of ...

Page 5: ...haust system A combination of grease and lint creates a potential fire hazard Do not use duct longer than specified in the exhaust length table Longer ducts can accumulate lint creating a potential fire hazard Never install a screen in or over the exhaust duct This will cause lint to accumulate creating a potential fire hazard Do not assemble ductwork with any fasteners that extend into the duct T...

Page 6: ...lide one end of the duct over the clothes dryer outlet pipe 2 Secure the duct with a clamp 3 With the dryer in its permanent position extend the duct to its full length Allow 2 of duct to overlap the exhaust pipe Cut off and remove excess duct Keep the duct as straight as possible for maximum airflow 4 Secure the duct to the exhaust pipe with the other clamp rs ELBOW REOUIRED ELBOWS REOUIRED LEVEL...

Page 7: ... at least 25 sq in for introduction of outside air into the dryer room i 27GARAGEINSTALLATION IF ALLOWED BY LOCAL CODES Dryers installed in garages must be elevated 18 inches a6cm above the floor _ _DRYER EXHAUST TO LEFT OR BOTTOM CABINET WARNING BEFORE PERFORMING THIS EXHAUST INSTALLATION BE SURE TO DISCONNECT THE DRYER FROM ITS ELECTRICAL SUPPLY PROTECTYOUR HANDS AND ARMS FROM SHARP EDGES WHEN W...

Page 8: ...DING ELBOW FOR EXHAUST THROUGH BOTTOM OF CABINET Insert the elbow through the rear opening and connect it to the dryer internal duct Apply duct tape on the joint between the dryer internal duct and elbow as shown above CAUTION Internal duct joints must be secured with tape otherwise they may separate and cause a safety hazard ADDING COVER PLATE TO REAR OF CABINET PLATE KIT WEIM454 Connect standard...

Page 9: ... rfgido o de tipo papal de aluminio debe estar aprobado par ULe instalarse de acuerdo con las instrucciones de C6mo conectar la secadora a la ventilaci6n dom stica de lap6gina 5 deeste manual Losmaterialesde ventilaci6n flexibles a menudo se desploman se aplastan y atrapan pelusas Estascondiciones obstruyen la corriente de aire de la secadorae incrementan el riesgo de incendio No instale o almacen...

Page 10: ...ASLASCONVERSIONES DEBEN LLEVARLAS A CABOPERSONAL CAPACITADO YCALIFICADO ENCUMPLIMIENTO CONCODIGOSLOCALES Y REq UERIIVllEN TOSDEORDENANZAS Lasecadora debe desconectarse del sistema de tuber a de suministro de gas durante cualquier prueba de presi6n del sistema con una presi6n de prueba mayor a 0 5 PSI 3 4 KPa Lasecadora debe aislarse del sistema de tuber a de sum inistro de gas cerrando la vc_lvula...

Page 11: ...deben conectarse directamente en las roscas de la tuber a APLIQUECOM PUESTO PARA TUBERiA AL ADAPTADOR V A LA ENTRADA DE GAS DE LASECADORA Ajustelatuberiaflexible degasutilizando dosIlavesajustables APLIQUE COMPUESTO PARA TU BERiA EN TODAS LAS ROSCAS MACHO Ajuste todas las conexiones mediante dos Ilaves ajustables iNo ajuste de m6s las conexiones de gas PRUEBA DE DETECCI6N DE PI_RDIDAS ADVERTENCIA ...

Page 12: ...crementar6n los tiempos de secado y el costo de energia Reducir6 la vida 6til de la secadora Acumular6 pelusa Io que podria generar un riesgo potencial de incendio La correcta instalaci6n de salida es SU RESPONSABILIDAD Los problemas generados por una instalaci6n incorrecta no se encuentran cubi ertos por la garantia Quite y descarte el conducto de transici6n existente de pl6stico o de papel de al...

Page 13: ...a La combinaciGn de grasa y pelusas podr a provocar un riesgo potencial de incenclio No utilice un conclucto de una Iongitucl mayor a la especificada en la tabla de Iongitud de salida Los conductos rags largos acumulan pelusa Io que genera un riesgo potencial de incendio Nunca instale un filtro clentro o sobre el conclucto de salida Esto provocar6 la acumulaciGn de pelusas Io que genera un riesgo ...

Page 14: ...e la tuberfa de salida de la secadora de ropa Fije el conducto con una abrazadera Con la secadora en su posici6n permanente extienda el conducto en su Iongitud total Deje qua se superpongan 2 de conducto con la tuberfa de salida Carte y quite el tramo de conducto qua sabre Mantenga el conducto Io m6s recto posible para Iograr una corriente de aire m6xima 4 Fijeel conducto a la tuberfa de salida co...

Page 15: ...nivel del piso SALIDA DE LA SECADORA HACIA LA IZQUIERDA O PARTE INFERIOR DEL GABINETE EFECTUAR ESTAINSTALACI6N DE SALIDA ASEGURESE DE DESCONECTAR LASECADORA DELSUMINISTROELECTRICO PROTEJASUS PIANOSY BRAZOSDE LOSLADOSAFILADOS CUANDO TRABAJEDENTRODELGABINETE ASEGURESE DE USARGUANTES OUITE EL TORNILLO Y CONSERVEL QUITE _ EL RECORTE DESEADO SOLO UNO Despegue y quite el recorte inferior derecho o izqui...

Page 16: ...DAA TRAVI_S DE LA PARTEINFERIORDELGABINETE Introduzca el coda a tray s de la abertura trasera y con6ctelo al conducto interno de la secadora Aplique cinta aislante en lajunta entre el conducto interno de la secadora y el coda coma puede verse abajo k A PRECAUCI6N Lasjuntas delconductointerno deben sujetarse con cinta casocontrario pueden separarse y provocar un riesgo de seguridad C6MO AGREGAR LA ...