GE GEH-ECG 1200 User Manual Download Page 12

ECG Cables and Accessories 

Page 12 

    

2102322-111 REV 1

 

ECG Cables and Accessories 

Accessories 

Part Number 

Leadwires with Snaps IEC 

2102322-011 

Leadwires with Snaps AHA 

2102322-012 

Leadwires with Clips IEC 

2102322-013 

Leadwires with Clips AHA 

2102322-014 

Black belt for 1200W acquisition unit 

2102322-015 

USB cable 3m for 1200WR Receiver 

2102322-053 

BNC cable 3m for 1200WR Receiver 

2102322-054 

Technical Specifications 

1200W (Acquisition unit) 

ECG 

Lead system 

Standard 12 Lead 

Patient Leads 

Detachable 10 Lead wires conform to AAMI 

Defibrillation protection 

Protected against 360J discharge 

Patient leakage current 

< 10 uA 

Input impedance 

> 10 MOhm

CMMR 

> 90dB

Frequency range 

0.05 – 150Hz 

Dynamic range 

+/- 2.4V 

Resolution 

24 bits (0.286 uV/LSB) 

Sample Rate Internal 

8000 

Sample Rate Recording 

500 

Lead OFF Detection 

Yes 

Communication 

Digital RF 

2400 – 2483 MHz, 

0.4mW, conform to FCC Part 15.249 

Power 

Battery 

Size AA x 2, Alkaline or NiMH 

Operation time 

Up to 40 hours with Alkaline Batteries 

Mechanical

 

Size 

140 x 95 x 50 mm 

Weight 

350g 

Environmental

 

Operating Temp. Range 

10 to 40 °C 

Storage  Temp. Range 

-20 to 60 °C

Relative  Humidity 

10 to 95 % (non-condensing) 

1200WR (Receiver) 

Auxiliary output

 

ECG Out Bandwidth (-3db) 

0.5 to 150 Hz 

ECG Out Gain 

1000 

ECG Out Sample Rate 

500 

TTL Trigger width 

16-128ms 

TTL Trigger delay 

<11ms (delay from R-wave) 

Communication

 

USB 

USB2.0 Full Speed 

Digital RF 

2400 – 2483 MHz, 

0.4mW, conform to FCC Part 15.249 

Power

 

USB 5V 

100mA max at 5V input 

Mechanical 

Size 

100 x 54 x 30 mm 

Weight 

80g 

Environmental 

Operating Temp. Range 

10 to 40 °C 

Storage  Temp. Range 

-20 to 60 °C

Relative  Humidity 

10 to 95 % (non-condensing) 

Regulatory 

Safety Standards 

IEC 60601-1, 60601-1-2, 60601-2-25 

Classification 

Type CF with defibrillation proof. Internally powered 

Certification 

CE, FDA 

Summary of Contents for GEH-ECG 1200

Page 1: ...322 111 REV 1 NOTE The information in this manual only applies to the product GEH ECG 1200 Due to continuing product innovation specifications in this manual are subject to change without notice 2019 General Electric Company All rights reserved ...

Page 2: ...e program other than the original design or intended use thereof is not advised and considered a misuse of the software product Norav Limited Warranty Norav products are warranted to be free from manufacturing and material defects for a period of one 1 year from the date of shipment from Norav or the dealer to the original purchaser Excluded from this warranty are expendable supply items including...

Page 3: ...ols and Indicators 6 Battery Assembly 7 Belt Strap Assembly 8 Electrode Application 8 Patient Leadwires Assembly 9 Maintenance and Cleaning 10 Storage 10 Service 11 Calibration 11 Troubleshooting 11 ECG Cables and Accessories 12 Technical Specifications 12 Electromagnetic Emissions and Immunity Information 13 ...

Page 4: ...e device or signify an important step or procedure that requires special attention Device Labels Symbols Definition Defibrillation proof type CF Applied part Caution Refer to operation manual NOTE On ME EQUIPMENT Follow instructions for use 2797 CE marking Manufacturer Name and Address Device Serial Number Device Reference Number Date of manufacture Contains MIC certified RF module FCC ID Contains...

Page 5: ...hich are part of the system must meet the requirements of the Standard for Information Technology Equipment IEC EN 60950 1 and the Standard for Electrical Medical Devices IEC EN 60601 1 The personal computer should be approved to the appropriate safety standard for non medical electrical equipment IEC EN 60950 1 or its national variants Accessory equipment connected to the analogue and digital int...

Page 6: ...nd This device must accept any interference received including interference that may cause undesired operation The manufacturer is not responsible for any Radio or TV interference caused by unauthorized modifications to this equipment Such modifications could void the user s authority to operate the equipment NOTE NO OPTIMUM WIRELESS PERFOMANCE Note that the complete data transfer cannot be guaran...

Page 7: ...ore than two weeks when the recorder is not in use If you use rechargeable batteries the battery recharger should be kept out ofthe patient environment and hook up area Dispose of used batteries carefully using environmentally friendly methods wherever possible following the state s recycling laws or your facility srecycling policy Use only the recommended battery type as instructed in the technic...

Page 8: ...suitable for use As ECG electrodes from different manufacturers have different electrical properties the choice of ECG electrodes can considerably affect the measurement results and quality Ensure that only high quality electrodes are used Wet gel electrodes are recommended Always refer to the ANSI AAMI EC12 2000 Standard for safety performance and labeling requirements for the disposable electrod...

Page 9: ...eat height or wear and tear chafed patches on the cable Do not use the instrument or the leadwires if you detect cracks melted areas or any other signs of damage to the leadwires or housing Caution Verify that dates on applicable accessories have not expired ECG electrodes can cause skin irritation Examine the skin for signs of irritation or inflammation and avoid placement of the electrode in tho...

Page 10: ... measures as the rejected items Use the recorder after all the items become accepted Unit check shall be performed by each medical institution or by Norav personnel representative agent or an authorized third party For more details do not hesitate to consult your dealer or Norav Medical personnel Details of the check Check Method Criteria Operation manual Check that the operation manual is kept in...

Page 11: ...te before packing unless you suspect they are associated with the problem Wherever possible use the original shipping carton and packing materials Include a packing list and the Norav Return Material Authorization RMA number It is recommended that all returned goods be insured Claims for loss or damage to the product must be initiated by the sender Calibration The device does not need any calibrat...

Page 12: ...500 Lead OFF Detection Yes Communication Digital RF 2400 2483 MHz 0 4mW conform to FCC Part 15 249 Power Battery Size AA x 2 Alkaline or NiMH Operation time Up to 40 hours with Alkaline Batteries Mechanical Size 140 x 95 x 50 mm Weight 350g Environmental Operating Temp Range 10 to 40 C Storage Temp Range 20 to 60 C Relative Humidity 10 to 95 non condensing 1200WR Receiver Auxiliary output ECG Out ...

Page 13: ...N A Mains power quality should be that of a typical commercial or hospital environment Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec N A Mains power quality should be that of a typical commercial or hospital environment Po...

Page 14: ...ween portable and mobile RF communications equipment and NR recorder This device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled Users of this device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communication equipment transmitters and the device as recommended below according t...

Page 15: ...Electromagnetic Emissions and Immunity Information 2102322 111 REV 1 Page 15 ...

Page 16: ...www gehealthcare com ...

Reviews: