Summary of Contents for GE100

Page 1: ......

Page 2: ... to help you better manage your diabetes The GE100 Blood Glucose Monitoring System is perfect for both self testing and professional use Designed for in vitro diagnostic use only testing requires just a small amount of fresh capillary whole blood from either the fingertip palm or forearm If you have any questions regarding the GE100 Blood Glucose Monitoring System or testing procedures contact our...

Page 3: ...ial blood testing yet so it is not suitable to be used for arterial blood testing Follow all environmental protection regulations when disposing of batteries GE100 GE100 GE100 GE100 GE100 GE100 GE100 Do not perform a blood glucose test when USB cable is connected to the Blood Glucose Meter If the GE100 Blood Glucose Meter and Test Strips are exposed to a substantial change in temperature please wa...

Page 4: ...s 51 Essential Components List 52 Log Book 53 Warranty Card 66 Emergency Card 69 About The System The Blood Glucose Monitoring System 8 The Blood Glucose Meter 10 The Blood Glucose Test Strip 14 Before Testing Meter Activation and Battery change 16 Setting Up Your Meter Setting the Time Volume and Date 18 Turning On Off the Meter 21 Handling the Test Strip 22 Testing Procedure Getting Ready for Te...

Page 5: ... Test Strip Package Insert 4 GE100 Control Solution Package Insert 5 GE100 Blood Glucose Meter with 1 CR2032 batteries installed 6 GE100 Blood Glucose Test Strips 0 10 25 pcs 7 GE100 Control Solution 8 GE Lancing Device 9 Clear Cap 10 Disposable Sterile Lancets 10 pcs 11 Carrying Case not shown 12 Instructions For The Lancing Device not shown Different packages have different bundled items Some of...

Page 6: ...y Window Test Strip Port Product name Battery Cover Meter Serial Number Meter Battery The Blood Glucose Meter GE100 GE100 USB Port For data downloading on authorized GE software only NOTE Do not perform a blood glucose test when USB cable is connected to the Blood Glucose Meter ...

Page 7: ...replaced Indicates when to apply the blood sample Test strip Occurs when strip is not compatible with your meter or if a strip is inserted incorrectly Current date under time mode or testing date under memory mode Indicates if the environmental temperature limit is exceeded during testing Indicates the time in 12H format Current time or testing time under memory mode under time mode Manufacturing ...

Page 8: ...nsert If the GE100 Blood Glucose Meter and Test Strips are exposed to a substantial change in temperature please wait 30 minutes before measurement When you open a new vial of GE100 Test Strips record the date on the vial View Window Hold here to insert test strip into meter Electrode Contacts Sensing signal output terminals Noble Metal Electrodes Electrochemical sensor Insertion Symbol The GE100 ...

Page 9: ...g up Meter Activation and Battery change Your GE100 Blood Glucose Meter comes with one CR2032 3volt battery installed One new battery will provide power to perform about 1000 tests under normal use Press the main button or insert a strip to activate your meter You can enter Setting Mode two ways 1 Replace Battery After removing the battery press the main button several times until there is no sign...

Page 10: ...firm Once the day is confirmed the Time setting will flash 1 2 3 4a 4b 5 6 7a 7 4 Time format 12 24H selection With the time format blinking press the Up or Down button to switch between 12H and 24H Press the Main button to confirm your hour setting Once confirmed the hour setting will flash 5 Hour setting With the hour blinking press the Up or Down button until you see the current hour Press the ...

Page 11: ...E100 will return to the time screen If the volume has not been turned off you will hear a beep 1 How to turn on the GE100 Blood Glucose Meter Press the Main button or insert a test strip 2 Manual Power off If you want to turn off the GE100 Blood Glucose Meter press and hold the Main button for 3 seconds 3 Auto Power off The Blood Glucose Meter will power off automatically after 2 minutes if no but...

Page 12: ...ort until it clicks and firmly stops Removing the GE100 Blood Glucose Test Strip 1 Hold the GE100 Blood Glucose Test Strip as shown 2 Rotate the GE100 Blood Glucose Test Strip counterclockwise and pull up simultaneously 3 Take the GE100 Blood Glucose Test Strip out of the test strip port Please follow your local regulations and discard used strips properly NOTE Test Strip Port will not be contamin...

Page 13: ...ub Lancet carrier Release button Safe switch Depth adjustable cap Performing a Blood Glucose Test 2 Pull off the depth adjustable cap 3 Insert a new disposable lancet firmly into lancet carrier Twist off and set aside the protective cover of the disposable lancet 5 Replace the depth adjustable cap 4 1 2 3 4 5 1 Hold the depth adjustable cap in one hand and hold the base with the other hand Bend th...

Page 14: ... soft or thin skin for average skin for thick or calloused skin 8 NOTE The GE100 Blood Glucose Meter will automatically detect the Code number on the strip You don t have to check the Code number on the meter display or strip vial 11 A blood drop icon will appear on the display window and will be accompanied by a beep if volume is turned on Apply the blood sample within 2 minutes 12 Place the lanc...

Page 15: ...g date of a new GE100 Blood Glucose Test Strip vial Discard the vial of test strips 3 months after opening 18 Test Strips 2009 10 01 Performing a Blood Glucose Test Alternative site testing palm or forearm blood sampling To do the alternative site testing install the clear cap for your GE100 Lancing Device For detailed information check the instruction manual for the GE Lancing Device To increase ...

Page 16: ...ot large enough for the meter Periodically compare the test system to a laboratory test system that is known to be well maintained and monitored by a healthcare provider Alternative Site Testing View Window Appearance Make sure your blood sample covers the whole area of the view window to get an accurate test result An insufficient blood sample will result in an error message Er4 If this occurs re...

Page 17: ...ediately If you are experiencing symptoms that are not consistent with your blood glucose test results and you have followed all of the instructions in this manual contact your healthcare professional immediately Understanding Test Results and Messages The GE100 Blood Glucose Meter displays results between 20 and 600 mg dL If your test result is below 20 mg dL will appear on the screen Please repe...

Page 18: ...ing 1 866 613 7085 GE100 GE100 Quality Control Test Use normal or high level Control Solutions when testing your Blood Glucose Monitoring System in the Control Solution Mode If the test result is within the Control Solution Range printed on the strip vial label your GE100 Blood Glucose Monitoring System passes the Quality Control Test and your GE100 Blood Glucose Monitoring System is working corre...

Page 19: ...ion from the top of the cap 8 The screen will display the count time starting from 5 you will hear a beep if the volume is turned on Performing a Quality Control Test OPEN 5 6 9 CAUTION Your Control Solution Test results will not be included in the Average calculations however they can still be recalled and viewed The Control Solution Test result will be shown with symbol on the screen Control Sol...

Page 20: ... the average value for the day By pressing the Up or Down button you will get to the 1 day 7 days 14 days 30 days and 90 days average of your blood glucose values You will see the number of the calculated days in the lower left corner and the number of the calculated readings in the lower right corner Down 3 Non Averaging set and canceled You may exclude unwanted or doubtful test results from the ...

Page 21: ... have to set the time and date to activate the average function The and results the control solution results and the test results measured when the meter was outside of its operating temperature range will not be included in the average Caring for Your Meter Maintenance Keep your GE100 Blood Glucose Meter and Test Strip free of dust water or any other liquid Store the meter in the carrying case wh...

Page 22: ...mediately Er1 The inserted test strip has been used or damaged Please use a new test strip from vial Er2 First replace the battery If Er2 appears after replacing the battery perform a perform a Quality Control Test see page 36 Performing a Quality Control Test Er3 Signal transmission is disrupted repeat the test see page 16 Meter Activation and Battery Change If the error messages continue after a...

Page 23: ...r Do not apply the blood drop to the sample entry of the strip before the GE100 Blood Glucose Meter displays If you do so the meter will display and accompanied by beeps if volume is turned on Please discard the test strip and repeat the test with a new GE100 Blood Glucose Test Strip Code Error When a test strip is not inserted correctly Code Error will flash on the screen Please reinsert the stri...

Page 24: ...F F C C NOTE Acetaminophen Ibuprofen Methyldopa Salicylic Acid Tetracycline Tolbutamide Bilirubin unconjugated Cholesterol Creatinine Triglyceride Maltose Xylose Galactose and Lactose when occurring in normal blood or normal therapeutic concentrations do not significantly affect results However abnormally high concentrations in blood may cause inaccurate results Sodium Fluoride Potassium Oxalate a...

Page 25: ...at this product will be free from defects in materials and workmanship for five years from the date of purchase This warranty does not apply to the performance of a GE100 Blood Glucose Meter that has been altered misused tampered with or abused in any way This warranty applies only to the original purchaser of the GE100 Blood Glucose Meter Please complete and return the enclosed warranty card Diff...

Page 26: ... 5 00 PM PST or visit our web site www gediabetes com We will make every effort to provide assistance and solutions for you Expected glucose values without diabetes Expected glucose values without diabetes Fasting Range mg dL 70 99 1 References 1 Diabetes Information American Association for Clinical Chemistry AACC Electronic Version Retrieved June 15 2010 from www labtestsonline org understanding...

Page 27: ...Manufacturer Bionime Corporation Product complies with Medical Device Directive 93 42 EC Disposable Sterile Lancets Manufacturer SteriLance Medical Suzhou Inc Product complies with Medical Device Directive 93 42 EEC CE0197 Essential Components List Log Book Name Address Home Phone Doctor Pharmacy Insulin Pills In case of emergency contact Work Phone Doctor s Phone Pharmacy Phone Log book date From...

Page 28: ...tion Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book ...

Page 29: ...tion Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book ...

Page 30: ...tion Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book ...

Page 31: ...tion Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book ...

Page 32: ...tion Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book ...

Page 33: ...tion Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Breakfast Lunch Dinner Bedtime Other Comments DATE M T W T F S S Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Blood Glucose Insulin Medication Log Book ...

Page 34: ...67 Distributor name and address PLACE STAMP HERE Warranty Card ...

Page 35: ...s or workmanship and provided it is not modified altered or misused will perform in accordance with specifications for a period of five 5 years from the original date of purchase 2 Guarantees the performance of the GE100 Blood Glucose Meter only if used as directed and provided that the failure to perform has not been caused in whole or in part by the use of test strips that are not GE100 Test Str...