background image

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

130676

Specification Created 11/08

Listed by 

Underwriters 

Laboratories

ZVB36SN/BN

GE Monogram

® 

36" Telescopic Downdraft Vents

Dimensions and Installation Information (in inches) 

Countertop Requirements 

Countertops must have a deep flat surface to accommodate 

the cooktop and the vent. Countertops with a rolled edge and 

backsplash may not provide the flat surface area required. 

Base Cabinet Requirements 

The base cabinet must be deep enough to accommodate the 

minimum clearance to the front edge of the countertop, the 

cooktop burner box and the vent.

Downdraft Vent and Cooktop Cutout 

The installation of these downdraft vents with any Monogram 

cooktop requires careful consideration. For accurate planning, 

review the individual dimension drawings for the combined vent 

and Monogram cooktop installation.

Before you begin you must:

1.  Review countertop dimension illustrations to be sure you will 

have enough flat countertop surface depth.

2.  Check to be sure that the total countertop depth required 

(including minimum cutout to front edge depth) allows enough 

space for a backsplash.

3.  Review the cabinet illustration. Check to be sure that the 

interior cabinet depth will house the cooktop burner box, the 

vent and the cutout clearance from the front.

4.  When countertop and cabinet depth present a problem, review 

Creative Solutions. 

5.  Carefully review the installation instructions packed with 

product or available online at www.monogram.com.

With careful planning you can achieve a custom look with 

minimal adjustments. 

ZVB36SNSS

Separate Raise/

Lower Switch

All 36" models are equipped with a separate raise/lower 

switch. The switch must be installed in a separate location 

outside of the vent and cooktop cutout.

Summary of Contents for GE Monogram ZVB36BN

Page 1: ...n For accurate planning review the individual dimension drawings for the combined vent and Monogram cooktop installation Before you begin you must 1 Review countertop dimension illustrations to be sure you will have enough flat countertop surface depth 2 Check to be sure that the total countertop depth required including minimum cutout to front edge depth allows enough space for a backsplash 3 Rev...

Page 2: ...anel Base Sink Filler Panel Maintain Cutout Clearances to Front Edge as Specified 605Dia160 Cover Panel Base Sink End Panel Countertop Overhang per Cooktop Clearances Must be Maintained 605Dia161 DOWNDRAFT VENT 1 7 8 Trim Add a Bullnose Trim or Decorative Molding to Increase Countertop Depth and to Maintain Required Clearance From Front Edge Optional Accessories JXRB67 Accessory for indoor remote ...

Page 3: ...ctrical and Gas Locations Plan the placement of the electrical outlet and gas if used carefully Gas or electrical outlets cannot be located on the back wall of the cabinet because they may interfere with the downdraft plenum Install a standard electrical outlet within reach of the vent s two foot long power cord Locate the outlet inside the cabinet on the right side wall If the vent is installed i...

Page 4: ... When You Cook Then Retracts When Not in Use 500 CFM Performance Helps Keep Your Kitchen Free of Fumes and Excess Heat Remote Mounted Control Provides Design Flexibility Variable Speed Blower with Electronic Controls Complements Most Monogram Cooktops Removable Grease Filters Trap Airborne Grease Particles Optional Remote Blower Capabilities Stainless Steel Vent Body Offers a Smooth and Polished A...