background image

GEH-5971B

INSTRUCTIONS

Garage Guardian

Garage Luminaire with Uplight Band

GENERAL

This luminaire is designed for pendant or ceiling mounting applications in a garage and should be

installed and maintained according to the following recommendations.

UNPACKING

This luminaire has been properly packed so that no parts should have been damaged during transit.

Inspect to confirm.

The carton should contain a luminaire complete with mounting assembly and the lamp installed in the

socket (medium base version only).

INSTALLATION

WARNING

Risk of electric shock

Turn power off before servicing

see instructions

CAUTION

Unit will fall if not installed properly

Follow installation instructions

WARNING

Risk of fire

Keep combustible materials away from lens

– see instructions

Use lamps specified on nameplate

Maintain minimum 3’ below luminaire

READ THOROUGHLY BEFORE INSTALLING

SAVE THESE INSTRUCTIONS FOR FUTURE USE

If unit is multi-volt, see Wiring Section.

Luminaire Mountings

A. Ceiling Mounting

1. Attach mounting plate to electrical junction box and pull incoming power leads through oval hole

in mounting plate.

2. Suspend luminaire below j-box and attach wireform by squeezing legs together slightly and

inserting through rectangular j-box mounting plate holes.

3. With luminaire hanging below j-box make electrical connections and place wires into j-box.

(Figure 1)

4. Swing luminaire into place, mate two mounting plates and slide together until plates lock into

place. (Figure 2)

5. To remove fixture from j-box, luminaire must be opened, by loosening three lens screws, then

loosening reflector screws, and removing reflector. The locking screw must be backed out

approximately one-half inch. (Figure 3)

B. Rigid Pendant Mounting

1. Loosen three lens screws and remove refractor and refractor ring from luminaire housing.
2. Loosen reflector screws, remove reflector.  Remove nomex wire shield.
3. Thread pendant/conduit into top housing (Figure 4) or mounting hub (Figure 6), and tighten lock

nut.

4. Feed wires through pendant and extend approximately 6 inches of wire into housing and make

necessary connections. (See Wiring section) Connect supply ground lead to the luminaire green

lead.

Figure 4

Figure 5

Locknut

(By User)

Cover

6  Inches

(152mm)

Cover

Connectors

Wire Clip

Ground Lead

Figure 2

Junction

Box

Mounting

Plate

Locking

Screw

Wire

Clip

Figure 3

Figure 1

Mounting

Plates

Wireform

5. Route incoming supply conductors through wire clip (D, Figure 5) provided.  Re-attach nomex

shield.

6. Reassemble luminaire.

C. Flexible Pendant Mounting

1. Follow procedure for rigid pendant mounting B1-B6.
2. If adjustment is needed to balance luminaire and have conduit hang vertical, loosen the four

screws in the slotted holes, slide the mounting hub until luminaire hangs straight, re-tighten

screws.  Use widest bolt spacing possible to secure hub to cover.

g

GE
Lighting Solutions

These instructions do not purport to cover all details or variations in equipment nor to provide for every possible contingency to be met in connection with installation, operation or
maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred
to GE Lighting Solutions.

Summary of Contents for Garage Guardian

Page 1: ...ned by loosening three lens screws then loosening reflector screws and removing reflector The locking screw must be backed out approximately one half inch Figure 3 B Rigid Pendant Mounting 1 Loosen three lens screws and remove refractor and refractor ring from luminaire housing 2 Loosen reflector screws remove reflector Remove nomex wire shield 3 Thread pendant conduit into top housing Figure4 or ...

Page 2: ... Incoming power lead should be stripped back 3 8 and firmly inserted in the plastic termination block on the desired voltage ballast lead LAMPS Use only lamps specified on nameplate Observe lamp manufacturer s recommendations and restrictions on lamp operation particularly ballast type burning position etc Lamp Tightness Mogul Base Lamp Lamp should be securely inserted to the NEMA EEI specified to...

Page 3: ...ssez le conduit de suspension dans le haut du carter Figure 4 ou le moyeu de montage Figure 6 et serrez l écrou de blocage 4 Passez les fils dans le conduit de suspension et sortez les d environ 15 cm dans le carter puis réalisez les connexions nécessaires voir la section sur le câblage Branchez le fil de terre de l arrivée d alimentation sur le fil vert du luminaire Figure4 Figure5 Écrou de bloca...

Page 4: ...POULES N utilisezquedesmodèlesd ampoulesspécifiéssurlaplaquesignalétique Suivezlesrecommandations et les restrictions de fonctionnement de son fabricant en particulier concernant type de ballast position d allumage etc Serrage d ampoule Culot Mogul L ampoule doit être bien insérée au couple de serrage spécifié NEMA EEI de 35 pied livres ce qui s obtient en serrant très fermement à la main Le serra...

Reviews: