3-10
G60 Generator Protection System
GE Multilin
3.2 WIRING
3 HARDWARE
3
3.2WIRING
3.2.1 TYPICAL WIRING
Figure 3–12: TYPICAL WIRING DIAGRAM
830721A4.CDR
(Rear View)
1
Power
Supply
9
CPU
MODULE ARRANGEMENT
J
U
M
X
L
W
K
V
B
H
T
D
N
G
S
P
F
R
No. 10AWG
minimum
GROUND
BUS
(DC
ONL
Y)
G60
G
ENERATOR
M
ANAGEMENT
R
ELAY
RS-232
DB-9
(front)
UR
C
OMPUTER
1
TXD
RXD
RXD
TXD
SGND
SGND
1
8
3
2
20
7
6
4
5
22
25
PIN
C
ONNECT
OR
9P
IN
C
ONNECT
OR
2
2
3
3
4
4
5
5
6
6
7
7
8
8
9
9
CONTACTS SHOWN
WITH NO
CONTROL POWER
6
Inputs/
outputs
8
VT/CT
8
CT
TC
TC
2
1
V
OL
TA
GE
SUPERVISION
V
OL
TA
GE
AND
CURRENT
SUPERVISION
CONTACT INPUT H5a
CONTACT INPUT H5c
CONTACT INPUT H6a
CONTACT INPUT H6c
COMMON H5b
CONTACT INPUT H7a
CONTACT INPUT H7c
CONTACT INPUT H8a
CONTACT INPUT H8c
COMMON H7b
SURGE
H6a
H8a
H5b
H7b
H8b
H5a
H7a
H6c
H8c
H5c
H7c
H1a
H2b
H1c
H1b
H2c
H2a
H4a
H4c
H3b
H3a
H4b
H3c
H1
H2
H3
H4
DIGITAL INPUTS/OUTPUTS
6G
I
V
I
V
I
V
I
V
CRITICAL
FAILURE
48 V DC
OUTPUT
CONTROL
POWER
HI
LO
P
OWER
SUPPL
Y
1
FILTER
SURGE
B3a
B1b
B8a
B6b
B8b
B6a
B3b
B1a
B2b
B5b
AC or DC
DC
F1c
F4a
F8c
F8a
F3c
F5a
F5c
F7c
CURRENT INPUTS
F6a
F7a
F6c
F2c
VX
VA
VB
VC
F4c
F1a
F4b
F1b
F2a
F3a
F2b
F3b
VOLTAGE INPUTS
8F / 8G
VX
VA
VB
VC
IA
IB
IC
IG
IA5
IA1
IB5
IC5
IG5
IB1
IC1
IG1
TYPICAL CONFIGURATION
THE AC SIGNAL PATH IS CONFIGURABLE
POSITIVE WATTS
M3c
M4c
M4b
M4a
M1c
M1a
M1b
M3b
CURRENT INPUTS
8F/8G or 8H/8J
M2a
M3a
M2b
M2c
IA
IB
IC
IG
IA5
IA1
IB5
IC5
IG5
IB1
IC1
IG1
A
B
C
R
MODULES MUST BE
GROUNDED IF
TERMINAL IS
PROVIDED
OPEN DELTA
VT CONNECTION (ABC)
F
F
F
F
F
F
5a
5c
7c
6a
7a
6c
VA
VB
VC
VOLTAGE INPUTS
VA
VB
VC
com
com
D1b
D2b
D3b
D1a
D2a
D4b
D3a
D4a
IRIG-B
Input
IRIG-B
Output
RS485
CO
M
1
RS485
CO
M
2
CPU
9E
BNC
BNC
Co-axial
*
-
For
IRIG-B
Input
only
use
one
terminal
as
input
Gr
ound
at
Remote
Device
Shielded
twisted
pair
s
Co-axial
Co-axial
Co-axial
*
This diagram is based on the following order code:
This diagram provides an example of how the device
is wired, not specifically how to wire the device. Please
refer to the Instruction Manual for additional details on
wiring based on various configurations.
G60-H00-HCH-F8F-H6G-M8H-PXX-UXX-WXX
GE Consumer & Industrial
Multilin
Summary of Contents for G60 UR Series
Page 2: ......
Page 4: ......
Page 12: ...xii G60 Generator Protection System GE Multilin TABLE OF CONTENTS ...
Page 32: ...1 20 G60 Generator Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 132: ...4 30 G60 Generator Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 392: ...5 260 G60 Generator Protection System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 418: ...6 26 G60 Generator Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 482: ...A 12 G60 Generator Protection System GE Multilin A 1 PARAMETER LISTS APPENDIXA A ...
Page 604: ...D 10 G60 Generator Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Page 616: ...E 12 G60 Generator Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Page 634: ...x G60 Generator Protection System GE Multilin INDEX ...