GE Multilin
F60 Feeder Protection System
B-17
APPENDIX B
B.4 MEMORY MAPPING
B
Expanded FlexStates (Read Only)
2B00
FlexStates, one per register (256 items)
0 to 1
---
1
F108
0 (Off)
Expanded Digital Input/Output states (Read Only)
2D00
Contact Input States, one per register (96 items)
0 to 1
---
1
F108
0 (Off)
2D80
Contact Output States, one per register (64 items)
0 to 1
---
1
F108
0 (Off)
2E00
Virtual Output States, one per register (96 items)
0 to 1
---
1
F108
0 (Off)
Expanded Remote Input/Output Status (Read Only)
2F00
Remote Device States, one per register (16 items)
0 to 1
---
1
F155
0 (Offline)
2F80
Remote Input States, one per register (64 items)
0 to 1
---
1
F108
0 (Off)
Oscillography Values (Read Only)
3000
Oscillography Number of Triggers
0 to 65535
---
1
F001
0
3001
Oscillography Available Records
0 to 65535
---
1
F001
0
3002
Oscillography Last Cleared Date
0 to 400000000
---
1
F050
0
3004
Oscillography Number Of Cycles Per Record
0 to 65535
---
1
F001
0
Oscillography Commands (Read/Write Command)
3005
Oscillography Force Trigger
0 to 1
---
1
F126
0 (No)
3011
Oscillography Clear Data
0 to 1
---
1
F126
0 (No)
Fault Report Indexing (Read Only Non-Volatile)
3020
Number of Fault Reports
0 to 65535
---
1
F001
0
Fault Report Actuals (Read Only Non-Volatile) (15 modules)
3030
Fault Report 1 Time
0 to 4294967295
---
1
F050
0
3032
Fault Report 2 Time
0 to 4294967295
---
1
F050
0
3034
Fault Report 3 Time
0 to 4294967295
---
1
F050
0
3036
Fault Report 4 Time
0 to 4294967295
---
1
F050
0
3038
Fault Report 5 Time
0 to 4294967295
---
1
F050
0
303A
Fault Report 6 Time
0 to 4294967295
---
1
F050
0
303C
Fault Report 7 Time
0 to 4294967295
---
1
F050
0
303E
Fault Report 8 Time
0 to 4294967295
---
1
F050
0
3040
Fault Report 9 Time
0 to 4294967295
---
1
F050
0
3042
Fault Report 10 Time
0 to 4294967295
---
1
F050
0
3044
Fault Report 11 Time
0 to 4294967295
---
1
F050
0
3046
Fault Report 12 Time
0 to 4294967295
---
1
F050
0
3048
Fault Report 13 Time
0 to 4294967295
---
1
F050
0
304A
Fault Report 14 Time
0 to 4294967295
---
1
F050
0
304C
Fault Report 15 Time
0 to 4294967295
---
1
F050
0
Modbus file transfer (read/write)
3100
Name of file to read
---
---
---
F204
(none)
Modbus file transfer values (read only)
3200
Character position of current block within file
0 to 4294967295
---
1
F003
0
3202
Size of currently-available data block
0 to 65535
---
1
F001
0
3203
Block of data from requested file (122 items)
0 to 65535
---
1
F001
0
Event recorder actual values (read only)
3400
Events Since Last Clear
0 to 4294967295
---
1
F003
0
3402
Number of Available Events
0 to 4294967295
---
1
F003
0
3404
Event Recorder Last Cleared Date
0 to 4294967295
---
1
F050
0
Event recorder commands (read/write)
3406
Event Recorder Clear Command
0 to 1
---
1
F126
0 (No)
DCMA Input Values (Read Only) (24 modules)
34C0
DCMA Inputs 1 Value
-9999999 to 9999999
---
1
F004
0
34C2
DCMA Inputs 2 Value
-9999999 to 9999999
---
1
F004
0
34C4
DCMA Inputs 3 Value
-9999999 to 9999999
---
1
F004
0
34C6
DCMA Inputs 4 Value
-9999999 to 9999999
---
1
F004
0
34C8
DCMA Inputs 5 Value
-9999999 to 9999999
---
1
F004
0
34CA
DCMA Inputs 6 Value
-9999999 to 9999999
---
1
F004
0
Table B–9: MODBUS MEMORY MAP (Sheet 9 of 53)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for F60 UR Series
Page 2: ......
Page 4: ......
Page 30: ...1 20 F60 Feeder Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 48: ...2 18 F60 Feeder Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Page 126: ...4 30 F60 Feeder Protection System GE Multilin 4 2 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 354: ...5 228 F60 Feeder Protection System GE Multilin 5 9 TESTING 5 SETTINGS 5 ...
Page 382: ...6 28 F60 Feeder Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 398: ...8 8 F60 Feeder Protection System GE Multilin 8 2 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 414: ...A 14 F60 Feeder Protection System GE Multilin A 1 PARAMETER LIST APPENDIXA A ...
Page 492: ...B 78 F60 Feeder Protection System GE Multilin B 4 MEMORY MAPPING APPENDIXB B ...
Page 530: ...D 10 F60 Feeder Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Page 542: ...E 12 F60 Feeder Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Page 558: ...x F60 Feeder Protection System GE Multilin INDEX ...