2-2
F60 Feeder Protection System
GE Multilin
2.1 INTRODUCTION
2 PRODUCT DESCRIPTION
2
Figure 2–1: SINGLE LINE DIAGRAM
2.1.2 ORDERING
The F60 is available as a 19-inch rack horizontal mount unit or a reduced size (¾) vertical mount unit, and consists of the
following modules: CPU, faceplate, power supply, CPU, CTs and VTs, digital input and outputs, transducer inputs and out-
puts, and inter-relay communications. Each of these modules can be supplied in a number of configurations specified at the
time of ordering. The information required to completely specify the relay is provided in the following tables (see chapter 3
for full details of relay modules).
Order codes are subject to change without notice. Refer to the GE Multilin ordering page at
http://www.GEindustrial.com/multilin/order.htm
for the latest details concerning F60 ordering options.
The order codes for the horizontal mount units are shown below.
Table 2–2: OTHER DEVICE FUNCTIONS
FUNCTION
FUNCTION
FUNCTION
Breaker arcing current (I
2
t)
Disconnect switches (8)
Non-volatile latches
Breaker control (2)
Event recorder
Non-volatile selector switch
Breaker flashover
Fault detector and fault report
Oscillography
Breaker restrike
Fault locator
Setting groups (6)
Cold load pickup (2)
FlexElements™ (8)
Time synchronization over SNTP
Contact inputs (up to 96)
FlexLogic™ equations
Transducer inputs and outputs
Contact outputs (up to 64)
High impedance fault detection (Hi-Z)
User-definable displays
Control pushbuttons
IEC 61850 communications (optional)
User-programmable LEDs
Data logger
Incipient cable fault detection
User-programmable pushbuttons
Demand
Load encroachment
User-programmable self-tests
Digital counters (8)
Metering: current, voltage, power, PF,
energy, frequency, harmonics, THD
Virtual inputs (64)
Digital elements (48)
Virtual outputs (96)
Direct inputs and outputs (32)
Modbus user map
VT fuse failure
832727AD.CDR
52
50P
2
2
2
2
2
2
2
2
2
2
2
2
2
6
4
2
1
1
1
2
2
50G
50_2
51G
51_2
79
CLOSE
TRIP
50BF
51P/V
67P
67_2
32
50N
51N
67N/G
50NBF
81U
81O
27P
59P
59N
59X
59_2
27X
25
Monitoring
F60
Feeder Management Relay
R
FlexElement
TM
Transducer
Inputs
METERING
32N
2
NOTE
Summary of Contents for F60 UR Series
Page 2: ......
Page 4: ......
Page 30: ...1 20 F60 Feeder Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 48: ...2 18 F60 Feeder Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Page 126: ...4 30 F60 Feeder Protection System GE Multilin 4 2 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 354: ...5 228 F60 Feeder Protection System GE Multilin 5 9 TESTING 5 SETTINGS 5 ...
Page 382: ...6 28 F60 Feeder Protection System GE Multilin 6 5 PRODUCT INFORMATION 6 ACTUAL VALUES 6 ...
Page 398: ...8 8 F60 Feeder Protection System GE Multilin 8 2 FAULT LOCATOR 8 THEORY OF OPERATION 8 ...
Page 414: ...A 14 F60 Feeder Protection System GE Multilin A 1 PARAMETER LIST APPENDIXA A ...
Page 492: ...B 78 F60 Feeder Protection System GE Multilin B 4 MEMORY MAPPING APPENDIXB B ...
Page 530: ...D 10 F60 Feeder Protection System GE Multilin D 1 IEC 60870 5 104 APPENDIXD D ...
Page 542: ...E 12 F60 Feeder Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...
Page 558: ...x F60 Feeder Protection System GE Multilin INDEX ...