Par. No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
O-54
Reversing Select
ExpressionLimit
All set-ups
TRUE
-
Uint8
O-55
Set-up Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
O-56
Preset Reference Select
[3] Logic OR
All set-ups
TRUE
-
Uint8
O-8#
O-80
Bus Message Count
0 N/A
All set-ups
TRUE
0
Uint32
O-81
Bus Error Count
0 N/A
All set-ups
TRUE
0
Uint32
O-82
Slave Messages Rcvd
0 N/A
All set-ups
TRUE
0
Uint32
O-83
Slave Error Count
0 N/A
All set-ups
TRUE
0
Uint32
O-89
Diagnostics Count
0 N/A
1 set-up
TRUE
0
Int32
O-9#
O-90
Bus Jog 1 Speed
100 RPM
All set-ups
TRUE
67
Uint16
O-91
Bus Jog 2 Speed
200 RPM
All set-ups
TRUE
67
Uint16
O-94
Bus Feedback 1
0 N/A
1 set-up
TRUE
0
N2
O-95
Bus Feedback 2
0 N/A
1 set-up
TRUE
0
N2
O-96
Bus Feedback 3
0 N/A
1 set-up
TRUE
0
N2
5.1.11 AO-## Analog I/O Option
Par. No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
AO-0#
AO-00
Terminal X42/1 Mode
[1] Voltage
All set-ups
TRUE
-
Uint8
AO-01
Terminal X42/3 Mode
[1] Voltage
All set-ups
TRUE
-
Uint8
AO-02
Terminal X42/5 Mode
[1] Voltage
All set-ups
TRUE
-
Uint8
AO-1#
AO-10
Terminal X42/1 Low Voltage
0.07 V
All set-ups
TRUE
-2
Int16
AO-11
Terminal X42/1 High Voltage
10 V
All set-ups
TRUE
-2
Int16
AO-14
Term. X42/1 Low Ref./Feedb. Value
0 N/A
All set-ups
TRUE
-3
Int32
AO-15
Term. X42/1 High Ref./Feedb. Value
100 N/A
All set-ups
TRUE
-3
Int32
AO-16
Term. X42/1 Filter Time Constant
0.001 s
All set-ups
TRUE
-3
Uint16
AO-17
Term. X42/1 Live Zero
[1] Enabled
All set-ups
TRUE
-
Uint8
AO-2#
AO-20
Terminal X42/3 Low Voltage
0.07 V
All set-ups
TRUE
-2
Int16
AO-21
Terminal X42/3 High Voltage
10 V
All set-ups
TRUE
-2
Int16
AO-24
Term. X42/3 Low Ref./Feedb. Value
0 N/A
All set-ups
TRUE
-3
Int32
AO-25
Term. X42/3 High Ref./Feedb. Value
100 N/A
All set-ups
TRUE
-3
Int32
AO-26
Term. X42/3 Filter Time Constant
0.001 s
All set-ups
TRUE
-3
Uint16
AO-27
Term. X42/3 Live Zero
[1] Enabled
All set-ups
TRUE
-
Uint8
AO-3#
AO-30
Terminal X42/5 Low Voltage
0.07 V
All set-ups
TRUE
-2
Int16
AO-31
Terminal X42/5 High Voltage
10 V
All set-ups
TRUE
-2
Int16
AO-34
Term. X42/5 Low Ref./Feedb. Value
0 N/A
All set-ups
TRUE
-3
Int32
AO-35
Term. X42/5 High Ref./Feedb. Value
100 N/A
All set-ups
TRUE
-3
Int32
AO-36
Term. X42/5 Filter Time Constant
0.001 s
All set-ups
TRUE
-3
Uint16
AO-37
Term. X42/5 Live Zero
[1] Enabled
All set-ups
TRUE
-
Uint8
AO-4#
AO-40
Terminal X42/7 Output
[0] No operation
All set-ups
TRUE
-
Uint8
AO-41
Terminal X42/7 Min. Scale
0 %
All set-ups
TRUE
-2
Int16
AO-42
Terminal X42/7 Max. Scale
100 %
All set-ups
TRUE
-2
Int16
AO-43
Terminal X42/7 Bus Control
0 %
All set-ups
TRUE
-2
N2