Par. No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
P-2#
P-20
Motor Construction
[0] Asynchron
All set-ups
FALSE
-
Uint8
P-24
Damping Gain
120 %
All set-ups
TRUE
0
Int16
P-25
Low Speed Filter Time Const.
ExpressionLimit
All set-ups
TRUE
-2
Uint16
P-26
High Speed Filter Time Const.
ExpressionLimit
All set-ups
TRUE
-2
Uint16
P-27
Voltage filter time const.
ExpressionLimit
All set-ups
TRUE
-3
Uint16
P-3#
P-30
Stator Resistance (Rs)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
P-31
Rotor Resistance (Rr)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
P-35
Main Reactance (Xh)
ExpressionLimit
All set-ups
FALSE
-4
Uint32
P-36
Iron Loss Resistance (Rfe)
ExpressionLimit
All set-ups
FALSE
-3
Uint32
P-37
d-axis Inductance (Ld)
ExpressionLimit
All set-ups
FALSE
-6
Int32
P-38
q-axis Inductance (Lq)
ExpressionLimit
All set-ups
FALSE
-6
Int32
P-39
Motor Poles
ExpressionLimit
All set-ups
FALSE
0
Uint8
P-4#
P-44
d-axis Inductance Sat. (LdSat)
ExpressionLimit
All set-ups
FALSE
-6
Int32
P-45
q-axis Inductance Sat. (LqSat)
ExpressionLimit
All set-ups
FALSE
-6
Int32
P-46
Position Detection Gain
100 %
All set-ups
TRUE
0
Uint16
P-47
Torque Calibration
ExpressionLimit
All set-ups
TRUE
-
Uint8
P-48
Inductance Sat. Point
ExpressionLimit
All set-ups
TRUE
0
Int16
P-6#
P-62
Locked Rotor Protection
ExpressionLimit
All set-ups
TRUE
-
Uint8
P-63
Locked Rotor Detection Time [s]
ExpressionLimit
All set-ups
TRUE
-2
Uint8
5.1.7 H-## High Perf Parameters
Par. No. #
Parameter description
Default value
4-set-up
Change
during
operation
Conver-
sion index
Type
H-0#
H-01
Option Detection
[0] Protect Option Config.
1 set-up
TRUE
-
Uint8
H-03
Restore Factory Settings
[0] Normal operation
All set-ups
TRUE
-
Uint8
H-04
Auto-Reset (Times)
ExpressionLimit
All set-ups
TRUE
-
Uint8
H-05
Auto-Reset (Reset Interval)
10 s
All set-ups
TRUE
0
Uint16
H-06
Fan Operation
[0] Auto
All set-ups
TRUE
-
Uint8
H-08
Reverse Lock
[2] Both directions
All set-ups
FALSE
-
Uint8
H-09
Start Mode
ExpressionLimit
All set-ups
TRUE
-
Uint8
H-3#
H-36
Trip Speed Low [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
H-37
Trip Speed Low [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
H-4#
H-40
Configuration Mode
ExpressionLimit
All set-ups
TRUE
-
Uint8
H-43
Torque Characteristics
[1] Variable torque
All set-ups
TRUE
-
Uint8
H-48
Clockwise Direction
[0] Normal
All set-ups
FALSE
-
Uint8
H-5#
H-50
Motor Magnetisation at Zero Speed
100 %
All set-ups
TRUE
0
Uint16
H-51
Min Speed Normal Magnetising [RPM]
ExpressionLimit
All set-ups
TRUE
67
Uint16
H-52
Min Speed Normal Magnetising [Hz]
ExpressionLimit
All set-ups
TRUE
-1
Uint16
H-58
Flying Start Test Pulses Current
ExpressionLimit
All set-ups
FALSE
0
Uint16
H-59
Flying Start Test Pulses Frequency
ExpressionLimit
All set-ups
FALSE
0
Uint16
H-6#
Parameter Lists
AF-600 FP
™
Programming Guide
DET-620D
03/2016 All rights reserved.
215
5
5