Operating Procedures
© 2015 General Electric Company – All rights reserved.
ADTS 405 Mk2 Instruction Manual-English | 25
The triple display always shows altitude and airspeed; with pressure units selected, the display
always shows Ps and either Qc, Pt or EPR. When
ALT
or
CAS
are selected the display shows the aim
and measured values of
ALT
and
CAS
as a dual display. With any other selected parameter the
display shows the measured values of altitude and airspeed and, the aim and measured value of the
other selected parameter. Additional display modes are available for certain options.
Note:
The ADTS 405 automatically returns to the pressure display if left
inactive in any set-up or menu type display for a period of more than one
minute.
Figure 3-2: Single Display
Figure 3-3: Dual Display
Controlled
or measured
parameter
Measured value
T for timed rate
of change
Units of
measurement
Alt
Aim
10000
10000
ft
WARMUP
Aim (set-point or target)
or “leak-measure” when
controller selected off
Pointer for
parameter
Special
messages
Measured values
T for timed rate
of change
Controlled
or measured
parameters
Units of
measurement
Aim (set-point or target)
or “leak-measure” when
controller selected off
Pointer for primary
parameter - aim that
changes on data entry
Special
message
ft
kts
Alt
Aim
CAS
Aim
10000
10000
582.0
600.0
Summary of Contents for Druck ADTS 405 R/F Mk2
Page 2: ......
Page 14: ...xii ADTS 405 Mk2 Instruction Manual English 2015 General Electric Company All rights reserved ...
Page 16: ...xiv ADTS 405 Mk2 Instruction Manual English 2015 General Electric Company All rights reserved ...
Page 18: ...xvi ADTS 405 Mk2 Instruction Manual English 2015 General Electric Company All rights reserved ...
Page 121: ......