SETUP
© 2017 General Electric Company – All Rights Reserved.
ADTS 405 R/F Mk2 Instruction Manual-English | 89
• ft and mph
• m and km/h (m/min)
• m and km/h (m/s)
• m and km/h (km/min)
7.3.18 SETUP, LEAK MEASURE CONTROL, [AUTO LEAK]
This function enables or disables the auto leak recovery facility. See Section 7.2.10, “LEAK
MEASURE/CONTROL,” on page 76.
7.3.19 SETUP, LEAK MEASURE CONTROL, [AUTO LIMIT]
This function enables or disables the auto limit recovery facility. See Section 7.2.10, “LEAK
MEASURE/CONTROL,” on page 76.
7.3.20 SETUP, GROUND
This function enables the station (airfield) altitude to be entered and is used when displaying
QNH. See Section 7.2.11, “GROUND,” on page 76 for further details.
a.
Enter the station (airfield) altitude in the units shown on the display. See
Section 7.4.3, “CONFIG, [UNITS],” on page 92, [AERONAUTICAL] units for the default
units.
7.3.21 SETUP, [PORT]
This function sets up the port option. If an option, that is not fitted, is selected the display
shows the error message “Option Hardware not fitted”. Refer to the Line Switching Unit, User
Manual.
7.3.22 SETUP, PRINT, [DATE/TIME]
This function allows the system time and date to be set. The time and date is maintained by a
battery-backed clock when the ADTS 405 Mk2 is switched off.
a.
Use [TIME] or [DATE] to select between time or date.
b.
To change the time or date, enter all six digits and press ENTER.
c.
The date format can be either US (mm/dd/yy) or UK (dd/mm/yy) using
CONFIG,[MORE], [DATE FORMAT]. The time format is hh:mm:ss.
7.3.23 SETUP, EXECUTE TEST PROGRAM
This function sets up the results file options.
Result data generated by the test program can either be sent out to the printer port or saved
to a result file and stored in the ADTS 405 Mk2. Pressing
F1
, the [PRINT/SAVE] key, sets the
option.
Any of the results files, stored in the ADTS 405 Mk2, can be sent to the printer port. Press
F2
,
the [PRINT FILE] key, to select the required file.
7.3.24 SETUP, HELP
This function provides help on the setup key.