GE DPSR610GGWT - Profile 7.0 cu. Ft. Gas Dryer Installation Instructions Manual Download Page 1

Installation

Instructions

Gas Dryer

If you have any questions, call 1-800-GECARES (US) or 1-800-361-3400 (Canada)

or

 

Visit our Web site at:

 www. GEAppliances.com

MATERIALS YOU WILL NEED

LEVEL

Step 1 Verify Your Gas Installation (see section 2).

Step 2 Prepare the Area and Exhaust for Installation of

New Dryer (see section 1).

Step 3 Check and Insure the Existing External Exhaust is

Clean (see section 1) and Meets Attached Installation

Specifications (see section 6).

Step 4   Remove the Foam Shipping Pads (see section 1).

Step 5 Move the Dryer to the Desired Location.

Step 6 Level Your Dryer (see section 8).

Step 7 Connect the Gas Supply (see section 3) and check

for leaks (see section 4).

Step 8 Connect the External Exhaust (see section 7).

Step 9   Connect the Power Supply (see section 5).

Step 10  Check the Operation of the Power Supply, Gas

Connections, and Venting.

Step 11  Place the Owners Manual and the Installation

Instructions in a Location Where They Will Be

Noticed By the Owner.

     For Alcove or Closet Installation see section 9.

     For Bathroom or Bedroom Installation see section 10.

     For Mobile or Manufactured Home see section 11.

8" PIPE WRENCH

DESIGN

CERTIFIED

06

In the state of Massachusetts, installation must be performed by a qualified 

or licensed contractor, plumber, or gasfitter qualified or licensed by the state.

    

WARNING

RISK OF FIRE

 

• To reduce the risk of severe injury or death, follow all installation instructions.

• Clothes dryer installation must be performed by a qualified installer.

• Install the clothes dryer according to these instructions and in accordance with 

local codes. In the absence of local codes, installation must comply with National 

Fuel Gas Code, ANSIZ223.1/NFPA 54 or the Canadian Natural Gas and Propane 

Installation Code, CSA B149.1.

• This dryer must be exhausted to the outdoors.

This act requires the governor of California to publish a list of substances known to the 

state to cause cancer, birth defects or other reproductive harm and requires businesses to 

warn customers of potential exposure to such substances. Gas appliances can cause minor 

exposure to four of these substances, namely benzene, carbon monoxide, formaldehyde 

and soot, caused primarily by the incomplete combustion of natural gas or LP fuels. 

Properly adjusted dryers will minimize incomplete combustion. Exposure to these 

substances can be minimized further by properly venting the dryer to the outdoors.

• 

California Safe Drinking Water and Toxic Enforcement Act

• Use only 4” rigid metal ducting for exhausting the clothes dryer to the outdoors.

• Do not install or store this appliance in any location where it could be exposed to 

water and or weather.

• Save these instructions. (Installers: Be sure to leave these instructions with the 

customer).

• DO NOT install a clothes dryer with flexible plastic ducting materials.  If flexible 

metal (semi-rigid or foil-type) duct is installed, it must be UL-listed and installed 

in accordance with the instructions found in "Connecting The Dryer To House 

Vent" on page 6 of this manual.  Flexible ducting materials are known to collapse, 

be easily crushed, and trap lint. These conditions will obstruct dryer airflow and 

increase the risk of fire.

BEFORE YOU BEGIN

Read these instructions completely and

carefully.

IMPORTANT-

 Save these

instructions for local inspector’s use.

IMPORTANT-

 Observe 

all governingcodes and ordinances.  

 

  

• 

Note to Installer

- Be sure to leave

these instructions with the customer.

 

• 

Note to Customer

 -

Keep these

instructions with your Use and Care

Book for future reference.

 Before the old dryer is removed from

service or discarded, remove the dryer

door.

 Service information and the wiring dia- 

gram are located in the control console. 

 Do not allow children on or in the

appliance. Close supervision of child-

ren is necessary when the appliance is

used near children. 

 

Install the dryer where the temp- 

erature is above 50°F for satisfactory 

operation of the dryer control system.

 

Inspect the dryer exhaust outlet and 

straighten the outlet walls if they are 

bent.

EXHAUST HOOD

FLEXIBLE GAS LINE CONNECTOR

SOAP SOLUTION

FOR LEAK DETECTION

PIPE

COMPOUND

DUCT TAPE

GLOVES

SAFETY GLASSES

4" DIAM METAL ELBOW

10" ADJUSTABLE WRENCHES

 (x2)

4" DUCT CLAMPS

OR

4" SPRING CLAMPS 

 (x2)

 (x2)

TOOLS YOU

WILL NEED

SLIP JOINT PLIERS

FLAT BLADE SCREWDRIVER

4" DIA. FLEXIBLE METAL (SEMI-RIGID)

UL LISTED TRANSITION DUCT

(IF NEEDED)

 KIT WX08X10077 (INCLUDES 2 ELBOWS)

4" DIA. METAL DUCT

(RECOMMENDED)

4" DIA. FLEXIBLE METAL (FOIL TYPE)

UL LISTED TRANSITION DUCT

(IF NEEDED.)

Summary of Contents for DPSR610GGWT - Profile 7.0 cu. Ft. Gas Dryer

Page 1: ...noxide formaldehyde and soot caused primarily by the incomplete combustion of natural gas or LP fuels Properly adjusted dryers will minimize incomplete combustion Exposure to these substances can be m...

Page 2: ...ng system by closing the equipment shut off valve during any pressure testing of the gas supply piping of test pressure equal to or less than 0 5 PSI 3 4 KPa WARNING DRYER GAS SUPPLY CONNECTION 2 2 5...

Page 3: ...nd fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location Keep flare end of adaptor free of grease oil and thread sealant...

Page 4: ...ance separate all turns by at least 4 ft of straight duct including distance between last turn and exhaust hood TURNS OTHER THAN 90 One turn of 45 or less may be ignored Two 45 turns should be treated...

Page 5: ...n a chimney a wall a ceiling gas vent crawl space attic under an enclosed floor or in any other concealed space of a building The accumulated lint could create a fire hazard Never terminate the exhaus...

Page 6: ...ront and rear DO NOT SIT DRYER ON FLEXIBLE EXHAUST DO NOT USE EXCESSIVE EXHAUST LENGTH DO NOT CRUSH FLEXIBLE EXHAUST AGAINST WALL DON T ELBOWS HIGHLY RECOMMENDED ELBOW HIGHLY RECOMMENDED DO CONNECTING...

Page 7: ...E ONLY FIXING HOLE BEND TAB UP 45 9 A B ADDING NEW DUCT Reconnect the cut portion A of the duct to the blower housing Make sure that the shortened duct is aligned with the tab in the base Use the scre...

Page 8: ...ENING 14 SERVICING REMOVE 4 HINGE SCREWS ROTATE DOOR 180 AND REINSTALL REMOVE 4 HOLE PLUGS AND PLACE THEM IN THE HOLES ON THE OPPOSITE SIDE WARNING LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICIN...