GE DNCD450EAWC Specifications Download Page 1

DNCD450EA/GA – GE Super 7.0 Cu. Ft. Capacity Commercial Dryer

Specification Revised 2/03

GE Appliances

Dryer Dimensions (in inches)

Exhaust Options:
Electric: 

4-way via rear, right, left and bottom. Maximum recommended exhaust

duct length is 45 feet of 4" rigid ducting with two 90° elbows and a 4" dampered
wall cap.

Gas: 

When viewed from the front of the unit, exhaust 3-way via rear, left and

bottom. Maximum recommended exhaust duct length is 15 feet of 4" rigid 
ducting with two 90° elbows and a 4" dampered wall cap.

Circuit Requirements:

An individual, properly-grounded branch circuit, protected by a 30-amp circuit
breaker or a time-delay fuse, is required.

Electric Dryer Rating: 

208/240V, 5600W, 24A, 60Hz
208V, 4400W, 22A, 60Hz

Note: 

Dryer wall outlet must be located within 36" of service cord entry and

accessible when dryer is mounted in position.

Installation Information: 

For complete information, see installation instructions

packed with your dryer.

36

42

27

2

3-1/2

2-1/2

25-1/2*

Side View

Rear View

8-1/2

28-1/4

23-1/2

11-1/2

*24-1/2" from the edge of the side panel to the front.
 25-1/2" from front to edge of endcaps.

For answers to your Monogram,

®

GE Profile

or 

GE appliance questions, visit our website at
GEAppliances.com or call 
GE Answer Center

®

service, 800.626.2000.