Page 1: ...removed from service or discarded remove the dryer door Inspect the dryer exhaust outlet and straighten the outlet walls if they are bent Service information and the wiring diagram are located in the control console Do not allow children on or in the appliance Close supervision of children is necessary when the appliance is used near children Install the dryer where the temperature is above 50 Ffo...
Page 2: ...N G Personal Injury Hazard Because of its weight and size more than one person is required to lift tilt or move the washer dryer Failure to do so may result in personal injury I REAR VIEW ATTACH CHAINS HERE 7 q C7 IC 7 STEP 1 Attach two chains using Phillips head screws to each end of upper unit cabinet STEP2 Locate two wall studs behind desired operating location of stacked units NOTE For wall st...
Page 3: ... A WARNING Installation must conform to local codes and ordinances or in their absence the NATIONALFUELGAS CODE ANSIZ223 This gas dryer is equipped with a Valve Burner Assembly for use only with natural gas Using conversion kit WE25X0217 your local service organization can convert this dryer for use with propane LP gas ALL CONVERSIONS MUSTBEMADEBYPROPERLY TRAINED AND QUALIFIEDPERSONNEL AND IN ACCO...
Page 4: ...AUTION Use adaptors as shown Connector nuts must not be connected directly to pipe threads APPLYPIPECOMPOUND TO THEADAPTER AND DRYER GASINLET Tightentheflexible gasline usingtwo adjustablewrenches I APPLYPIPECOMPOUND TO ALL MALETHREADS Tighten all connections using two adjustable wrenches Do not over torque gas connections LEAK TEST _ZlWARNING NEVER USE AN OPEN FLAME TO TEST FOR GAS LEAKS OPEN GAS...
Page 5: ...length for rigid metal duct is shown in the table below No of 90 Elbows 0 1 2 RECOMMENDEDMAXIMUM LENGTH Exhaust Hood Types Recommended Useonly for short run installations _ DIA RigidMetal RigidMetal 45 ft 30ft 35ft 20ft 25ft 10ft More than two 90 turns is not recommended The total length of flexible metal duct shall not exceed 8 ft 2 4m In Canada and in the United States the required exhaust duct ...
Page 6: ...he opening at the back with the plate Kit WE1M454 available from your Local Service Provider ZILWARNING NEVER LEAVE THE BACK OPENING WITHOUT THE PLATE PARTS AVAILABLE FROM LOCAL SERVICE ORGANIZATION Rigid Metal Duct Components WX8X63 4 X 1 Duct WX8X64 4 x 2 Duct WX8X51 4 Elbow WX8X59 Aluminum Hood Flexible Metal Duct Components WX08X10077 4 dia Flexible Metal Semi Rigid UL Listed Transition Duct i...
Page 7: ...TIONAL FUELGASCODE ANSIZ223 NOTE TO INSTALLER AFTER INSTALLATIONCHECKTHE FOLLOWING EXHAUST DUCT Must meet specs in the EXHAUST INFORMATION section GROUNDING Dryermust beproperly groundedto conform to localcodesand ordinance requirements OPERATION Turndryer on and checkfor heat Handcustomerthe Owner sManual Giveinstructionson operatingthe dryer Answerany questions GivetheseInstallationInstructionst...
Page 8: ...Installation Instructions ...