21
Ignitor glowing?
No Heat - Drum Turns
Gas Dryer
Flame sensor
contacts closed?
N
Y
Contacts A & B
closed on the
timer?
Y
Replace flame
sensor
N
Ignitor between
50 and 400 ohms
at room
temperature?
Flame sensor
contacts open
after ignitor has
been on 15 to 90
seconds max.?
Y
Gas valve
solenoids check
OK?
Y
120 volts to gas
valve solenoids?
Y
Replace timer
N
Contacts 1 & 2
closed on the
temperature
selector switch?
Contacts on the
control thermostat
closed?
Contacts on the
high limit
thermostat
closed?
Y
Y
Y
Replace control
thermostat
Replace
selector switch
N
N
Replace high limit
thermostat
N
Y
Replace ignitor
Replace flame
sensor
Replace gas
valve assembly
Replace gas
valve assembly
N
N
N
N
Fix supply
problem
Gas supply OK
to dryer?
N
Y
Continuity
between contact
1 and 2 on the
centrifugal
switch?
Manuall move the
switch to the run
position to check
the contacts.
Replace
motor
N
Open wiring to
one of the
components.
Locate and repair.
Y
Y
Open wiring in
gas valve circuit,
locate and repair
Not applicable
on all models
temperature
Greenwald
Summary of Contents for DCB330EY
Page 3: ...2 ...
Page 4: ...3 ...
Page 7: ...6 ...
Page 18: ...17 Ω Ω ...
Page 19: ...18 ...
Page 24: ...23 ...
Page 25: ...24 ...
Page 26: ...25 ...
Page 27: ...26 ...
Page 28: ...27 ...
Page 29: ...28 ...
Page 30: ...29 ...
Page 31: ...30 ...
Page 32: ...31 ...
Page 33: ...32 ...
Page 34: ...33 ...
Page 35: ...34 ...
Page 36: ...35 ...
Page 37: ...36 ...
Page 38: ...37 ...
Page 39: ...38 ...
Page 40: ...39 ...
Page 41: ...40 ...
Page 42: ...41 ...