20
Adequate voltage
to dryer at outlet?
No Heat - Drum Turns
Electric Dryer
Service fuse,
breaker, wall
outlet problem
N
Y
Replace power
cord
Contacts A & B
closed on the
timer?
Contacts 1 & 2
closed on the
temperature
selector switch?
Y
Contacts on the
control thermostat
closed?
Y
Contacts on high
limit thermostat
closed?
Y
Replace timer
Replace
selector switch
Replace control
thermostat
N
Heater resistance
OK?
Y
Correct voltage at
dryer terminal
block?
Y
Replace hi limit
thermostat
N
N
N
N
Replace heater
Replace
motor
Continuity
between contacts
1 & 2 on
centrifugal
switch? Manually
move the switch
to run position to
check these
contacts
Open wiring
between
components.
Locate and repair
N
N
Y
Y
Turn timer on
Not applicable
on all models
temperature
Greenwald