Dimensions and Installation Information (in inches) 

Exhaust Options: 

3-way via rear, left, and bottom.

Circuit Requirements: 

An individual, properly grounded 

branch circuit, protected by a 30-amp circuit breaker or 
a time-delay fuse, is required.

Note: 

Dryer wall outlet must be located within 36” 

of service cord entry and accessible when dryer is 
mounted in position.

Installation Information: 

For complete information, see 

installation instructions packed with your dryer.

27

1-5/8

41-1/2

31-1/8

5-1/2

3-3/4

Gas Dryer Rating

120V

60Hz, 6A

DBVH510GH 

GE

®

 7.0 Cu. Ft. Super Capacity Frontload Gas Dryer

 

Summary of Contents for DBVH510GH

Page 1: ...t and bottom Circuit Requirements An individual properly grounded branch circuit protected by a 30 amp circuit breaker or a time delay fuse is required Note Dryer wall outlet must be located within 36 of service cord entry and accessible when dryer is mounted in position Installation Information For complete information see installation instructions packed with your dryer 27 1 5 8 41 1 2 31 1 8 5 ...

Page 2: ...a dryer doors must contain a minimum of 120 sq in of open area equally distributed No other fuel burning appliance shall be installed in the same closet with a gas dryer Bathroom or Bedroom Installation The dryer MUST be exhausted to the outdoors The installation must conform with the local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 Minimum Clearance other tha...

Page 3: ...n For personal safety do not terminate exhaust into a chimney under any enclosed house floor crawl space or into an attic since the accumulated lint could create a fire hazard or moisture could cause damage Never terminate the exhaust into a common duct or plenum with a kitchen exhaust since the combination of lint and grease could create a fire hazard Exhaust ducts should be terminated in a dampe...

Page 4: ...selection and provide accurate cycle times Interior Dryer Light Lets you see everything inside for easy loading and unloading Quiet By Design Engineered for quiet operation Adjustable End Of Cycle signal Alerts you when cycle is done saving time between loads Multiple Dry Cycles Deliver optimal drying results Delay Start Lets you do the laundry on your terms Four Heat Selections Provide the right ...

Reviews: