2

Power Supply Installation

2

Connect the AC line to the black 

or brown (line) and white or 

blue (neutral) input wires of the 

power supply using suitable wire 

connectors.

Connect the supply wire that is 

attached to the Tetra LED System to 

the red (+) and black or blue (-) output 

wires of the power supply as outlined 

in the “Electrical Connections” 

section of your LED system’s 

Installation Instructions.
NOTE:

 To avoid overloading this 

power supply with LED modules, 

please refer to the specific module 

loading guides.

3

Input 

wires

White or blue 

(neutral)

Black or brown 

(line)

AC line

To Tetra LED System

Output 

wires

Red (+)

Black or blue (-)

1

Mount the power supply. Mounting 

the power supply base directly to 

a thermally conductive installation 

surface can improve thermal 

performance.
NOTE:

 All electrical connections 

should be suitably protected from 

mechanical damage and the 

environment. Seal all connections 

exposed to water with electrical 

grade self-hardening silicone.

 WARNING

RISK OF ELECTRIC SHOCK

AC input connections shall be 

suitably enclosed.

 CAUTION/ATTENTION

RISK OF INJURY
•  While performing installations described, gloves, safety 

glasses or goggles should be worn.

RISQUES DE BLESSURE
•  Lors de l’exécution des installations décrites, des gants, des lunettes de 

sécurité ou des lunettes de protection doivent être portées.

 WARNING/AVERTISSEMENT

RISK OF ELECTRIC SHOCK
•  Disconnect power at fuse box or circuit breaker before servicing 

or installing product.

•  Properly ground Tetra

®

 power supply.

RISK OF FIRE
•  Use only approved wire for input/output connection. Minimum 

size 18 AWG (0.82 mm

2

).

•  Follow all local codes.

•  Application considerations potentially requiring additional 

spacing include high ambient temperature seen by the 

power supply, poor contact with a heat dissipating material, 

inadequate ventilation, or direct exposure to sun.

RISQUES DE DÉCHARGES ÉLECTRIQUES
•  Coupez l’alimentation électrique à la boîte de fusibles ou au disjoncteur avant 

l’entretien ou l’installation du produit.

•  Assurez-vous de correctement mettre à terre le bloc d’alimentation Tetra

®

.

RISQUES D’INCENDIE
•  N’utilisez que des fils approuvés pour les entrées/sorties de connexion. 

Taille minimum 18 AWG (0.82 mm

2

).

•  Respectez tous les codes locaux.
•  Certaines applications pourraient requérir un espacement additionnel, p. 

ex. une température ambiante élevée autour du bloc d’alimentation, un 

mauvais contact avec une matière dissipatrice de chaleur, une ventilation 

inadéquate ou une exposition directe au soleil.

OPTIONAL 
A Weather Box (GEXNWB2) may be used to house 
and seal Class 2 connections. 
A) Insert wire connectors into weather box. Fill 

with electrical grade silicone and close box. 
B) Secure the weather box using a #6 or #8 (M2 

or M3) screw.

Weather box 

can be painted

Light engine

A

B