Product Information

Lamp technology

ConstantColor CMH™ lamps combine HPS technology
(providing stability, efficiency & uniformity) and Metal Halide
Technology (providing bright white quality light) to produce
highly efficient light sources with good colour rendering and
consistent colour performance through life. This is achieved
by using the ceramic arc tube material from the Lucalox™
lamp, which minimises the chemical changes inside the
lamp through life. When combined with the halide doses
used in Arcstream™ Metal Halide lamps then the quality
and stability of the dose maintains the colour consistency.
Hence the name ConstantColor CMH™.

Metal halide lamps, traditionally made with quartz arc tubes,
are prone to colour shift through life and lamp-to-lamp
colour variation. Some of the dose, e.g. sodium, (an
important component of metal halide lamps), can migrate
through quartz to cause colour shift and loss of light through
life. The ceramic arc tube resists this material loss, can be
manufactured to tighter tolerances and withstands a higher 
temperature to provide a more constant colour.

Features

• Consistent colour over life
• Good colour uniformity lamp to lamp
• Bright light – in a very compact size
• Excellent colour rendition
• Improved reliability due to 3 part design
• Up to 97 Lumen per Watt (LPW) efficacy 
• Up to 15,000 Hr life
• UV control

 

• Colour temperatures 3000K, 4200K

Single ended format

Single ended Ceramic Metal Halide lamps are designed to
provide symmetrical beam distribution using the axial con-
figuration of the discharge arc.  
A variety of beam angles are possible and adjustable beam 
control can be built into the luminaire.
This compact lamp shape enables luminaire size to be
minimised and the bi-pin lamp base enables easy changing 
with front access.

Applications areas

• Retail
• Offices
• Stage/Studio
• Architectural lighting
• Display Cabinet
• Hotels

D

A

TASHEE

T

Safety warnings

The use of these products requires awareness of the following safety issues:

Warning

• Risk of electric shock - isolate from power supply before changing lamp
• Strong magnetic fields may impair lamp performance 

 

and worst case can lead to lamps shattering 

Use in enclosed fixtures to avoid the following:

• Risk of fire.
• A damaged lamp emits UV radiation which may cause eye/skin injury
• Unexpected lamp shattering may cause injury, fire, or property damage

Caution

• Risk of burn when handling hot lamp
• Lamp may shatter and cause injury if broken
• Arc tube fill gas contain Kr-85

Always follow the supplied lamp operation and handling instructions.

www.ge.com/eu/lighting

and General Electric are both registered trademarks

of the General Electric Company

GE Lighting is constantly developing and improving its products. For this reason, all product descriptions in this brochure are intended as a 
general guide, and we may change specifications time to time in the interest of product development, without prior notification or public an-
nouncement. All descriptions in this publication present only general particulars of the goods to which they refer and shall not form part of any 

contract. Data in this guide has been obtained in controlled experimental conditions. However, GE Lighting cannot accept any liability arising 
from the reliance on such data to the extent permitted by law. CMH Single Ended G8.5 Product Information for OEMs 

17th July, 

2007

Summary of Contents for ConstantColor CMH G8.5

Page 1: ...of the discharge arc A variety of beam angles are possible and adjustable beam control can be built into the luminaire This compact lamp shape enables luminaire size to be minimised and the bi pin lamp base enables easy changing with front access Applications areas Retail Offices Stage Studio Architectural lighting Display Cabinet Hotels DATA SHE E T Safety warnings The use of these products requi...

Page 2: ...nly with an electronic ballast See additional notes on electronic ballast requirements for 20W Specification summary 20W 3000K 35W 3000K Plus 35W 4200K 70W 3000K Plus 70W 4200K Photometric Characteristics Product code 39858 43237 26348 43274 26349 100 hrs Lumens lm 1650 3400 3150 6200 6000 Typical Lumen change with burning position vertical to horizontal lm 100 150 Typical voltage change with burn...

Page 3: ...he information provided is intended to be a practical guide for comparison with other lamp types Determination of lamp replacement schedules will depend upon relative costs of spot or group replacement and acceptable reduction in lighting levels Note Representative curves are shown for Vertical Base Up lamp orientation unless otherwise specified Life performance is significantly increased in the H...

Page 4: ...ime thousand hours of Initial Lumen Maintenance 70W G8 5 3000K 40 20 0 60 80 100 2 4 6 8 10 12 14 16 0 Burning time thousand hours of Initial Lumen Maintenance 35W G8 5 3000K 40 20 0 60 80 100 2 4 6 8 10 12 14 16 0 85 80 75 70 65 60 90 95 100 2 4 6 8 10 12 0 Lumen Maintenance 35W G8 5 4200K Burning time thousand hours of Initial 85 80 75 70 65 60 90 95 100 2 4 6 8 10 12 0 Lumen Maintenance 20W G8 ...

Page 5: ...d dose Arc tube leakage into the outer jacket can be observed by a sudden and significant lumen drop and a perceptible color change usually towards green The above situation is often accompanied by the so called rectification phenomena This occurs where a discharge is established between two mount frame parts of different material and or mass causing asymmetry in the electrical characteristic of t...

Page 6: ...arc tube failure The IEC61167 requirement applies to both ceramic and quartz arc tube metal halide lamps of the UV A UV B and UV C spectral ranges as well as material temperatures when designing luminaires ConstantColorTM CMH G8 5 lamps are compatible with a list of approved ballasts contact your GE representative for more information Stay magnetic field from conventional ballast At the design sta...

Page 7: ...2 13047 150 220 240 BLS E 150W CMH Integral 430 g 12 13050 150 220 240 BLS E 150W CMH R Remote 445 g 12 13053 System Performance 20W 35W 70W 150W System Power W 23 5 43 78 159 System lm W 72 79 79 88 Lumens lm 1700 3400 6200 14000 Lamp Power W 20 39 72 146 Lamp Efficacy lm W 85 87 86 96 Lamp Voltage Range V 70 125 70 125 70 125 70 125 Data shown relates to 3000K products Please see lamp data sheet...

Page 8: ... feature worth considering to prolong ignitor component life The timed on period must be adequate to allow lamps to cool and restart as described below A period of 10 15 minutes continuous or intermittent operation is recommended before the ignitor automatically switches off Timed ignitors specifically offered for High Pressure Sodium lamps where the period of operation is less than 5 minutes are ...