GE Concord 4 Quick Setup Manual Download Page 1

 

 

GE Concord 4 Quick Setup Guide

  

 
For more detailed information, please see the GE Installation Manual.  
 

1.

 

Planning your system 

 

a.

 

Wired Zones

:  A hardwired zone can consist of 1 or more sensors in a loop. 

Each zone loop must consist of similar sensors, that can be programmed the 
same.  

i.

 

Normally Open Sensors:

 Normally open sensors have an “Open” 

circuit until the sensor is tripped, it will then close the circuit. This 
change is detected by the panel, and causes the alarm. These sensors 
get wired in Parallel.  (See Wiring Diagrams) 

ii.

 

Normally Closed Sensors: 

Normally closed sensors have a “Closed” 

circuit until the sensor is tripped, it will then open the circuit. This 
change is detected by the panel, and causes the alarm. These sensors 
get wired in Series. (See Wiring Diagrams)

 

iii.

 

Powered Sensors:

 Powered Sensors, such as Motion detectors, Glass 

Break Detectors will require a 4 conductor wire. Two wires are for 
power connections, and two wires 
are for the zone connections. 

b.

 

Wireless Zones:

 Unlike wired zones, for 

each wireless sensor you will use 1 
wireless zone. Each sensor is programmed 
to a zone with all information for that 
individual sensor.  

 
 

2.

 

Wiring the System 

 
 

a.

 

Keypads: 

 All Keypads get wired to Pins 3, 

4, 5, and 6. the system will automatically 
detect the number of keypads connected 
to the system. Match the colors used on 
each pin, to the corresponding connections 
on the keypad.

 (See Diagram to Right) 

b.

 

Sensors:  

i.

 

Normally Open Sensors: 

Check 

the product documentation – If the 
Loop Type is “NO” or “Normally 
Open” then the sensors should be 
wired in Parallel with the zone. 

(See Diagram On Last Page) 

ii.

 

Normally Closed Sensors: 

Check 

the Product Documentation – If the 
Loop Type is “NC” or “Normally 
Closed” then the sensors are wired in Series with the zone 

(See 

Diagram to On Last Page) 

 
 

3.

 

Programming The System 

 
 

a.

 

Entering Programming Mode 

1. Make sure the system is disarmed in all partitions. 
2. Press 8 4321 0. The display shows “

SYSTEM PROGRAMMING”

 
 