background image

Summary of Contents for CLIMATISEUR AEM18*

Page 1: ...allation Optional 15 _ qndow Installation 9 14 Troubleshooting Tips 16 Consumer Support Consumer Support Back Cover Product Registration 17 18 Aarranty 19 AEMI8 AEM25 ENERGY STAR _labeled product ENERGY STAR As an ENERGY STAR_ partneL GE has determined that this product meets the ENERGY STAR guidelines for energy efficiency Write the model and serial numbers here Model Serial Find these numbers on...

Page 2: ...rior to product disposal If you are g tdng rid of an old product with refrigerants check wifl the company handling disposal about what to do HOWTOCONNECT ELECTRICITY Do not under any circumstances cut or remove the third ground prong from the power cord For personal safe_ this appliance must be properly grounded DO NOT use an adapter plug with this appliance The power cord of dfis appliance is equ...

Page 3: ..._ WARNING EXTENSION CORDS CAUTION DO NOT use an extension cord with any of the 230 208 voltmodels ge com READ ANDFOLLOW THIS SAFETY INFORMATION CAREFULLY SAVETHESE INSTRUCTIONS ...

Page 4: ...on while setting O 0 Delay timer Increase Decrease Pads Each touch of tile Increase Decrease pads on tile refit or tile Increase Decrease pads on tile remote control will set tile delay time when using tile Delay 1 24hrdmer _ Tile Set light will turn on while setting Fan Speed Pads Use to set tile tim speed to Low Med High or Auto on tile refit NOTE On tile remote control use tile tim speed Increa...

Page 5: ...idity Nommlly used when tile room is unoccupied NOTE Thefanmay continue to run for a short t me after thecompressorcycles off OFF The tim runs all tile time while tile COIlll I essoI cycles on and oJZ Fan Only Mode Use the Fan Only Mode at Low Med or High Iim speed to provide air circulation and filtering with rot cooling Since tim rely settings do not provide cooling a Set temperature cannot be e...

Page 6: ...ooling Select HighCoolor Med Cool with the TEMPEIL_TUI_E control at midpoint ForMaximum Cooling Select High Coolwith the TEMPERATURE c mtrol at the highest number available on v mr knob For Quieter Nighttime Cooling Select Low Cool with the TEMPERATURE c mtrol at midpoint TEMP Control The TEMP control is used to maintain the room temperature The compressor will cycle on and oft to kee I the room a...

Page 7: ...ss to open and close the dooi NOTE Tile remote control on some models will work with the control panel door open or closed Normal operating sounds _ Ybu may hear a pinging noise caused b v water being picked up and thrown against tile condenser on rainy days or when tile humidity is high This design teature helps relnove moisture and improve efficiency Ji Ym may hear the themmstat click when the c...

Page 8: ... in a ciishwashel A CAUti ON Do No roperate the conditioner without a filter becausedirt and I bt will clog it and reducepeffomTance Grille Frame Removal fif necessary for coil cleaning P em we the air filter See the Air Filter section above If present rein eve the gillle fl am e atta chin ent screw Grasp the lower corne_ of the grille fl ame while pressing in on tile case side tabs with yore fing...

Page 9: ...tlet you plan to use is only a 2 prong outlet it is your responsibility to have it replaced with a properly grounded 3 prong wall outlet Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits which could cause a pos...

Page 10: ...ARTS INCLUDED Appearance may vary Left accordion panel Window sash seal Foam top moruT _ingwindow gasket_ Right accordion panel Window locking bracket 2 V support 2 Bolt 2 nuts 2 Type A 6 Type B 4 Type C 7 Type D 6 Type E 4 Type F 2 10 ...

Page 11: ... WIDTH 2 LENGTH Long enough to fit inside the window frame THICKNESS To determine the thickness place a piece of wood on the stool to make it 1 2 higher than the top of the storm window frame or the vinyl frame Attach securely with nails or screws provided by the installer 1 2 higher than vinyl frame L on some windows W 1 2 higher __ ___ _ w d than storm window r_ frame _Stool _ Storm window frame...

Page 12: ... mounting rail BACK INSTALL THE CASE IN THE WINDOW Carefully slide the case into the window and center the case Lower the window behind the top mounting rail Pull the bottom of the case forward so that the bottom mounting rail is tight against the back of the window stool Mount the case to the window sill using 4 type E screws Drill pilot holes if necessary Stool Make sure the bolts and nuts are a...

Page 13: ...evel no more than a 1 2 bubble will be the correct case slant to the outside Extend the left and right accordion panels to the vertical window sashes Drill pilot holes and attach the top and bottom corners with 4 type D screws Type D screw Top mounting rail screw Type D screw Type D screw INSTALL SUPPORT BRACKETS AND THE FOAM TOP WINDOW GASKET Drill pilot holes and attach the support brackets with...

Page 14: ...ook it from its top hinges and set it aside Using the tab pull up slightly on the filter to release it and pull it down and out INSTALL THE AIR CONDITIONER IN THE CASE cont Pull the coiled power cord from its shipped position in the air discharge area Attach the front grille frame to the case by inserting the tabs on the grille frame into the slots on the front top of the case Guide the lever care...

Page 15: ...acle is available close to the hole location or make arrangements to install a receptacle Place the case in the wall opening and place wood support strips between the case bottom and the flashing on both sides of the bottom rail They should be the same height as the bottom rail and the same length as the wall opening 15 IMPORTANT cont Secure with 14 wood screws anchored at least an inch into the w...

Page 16: ...mn the air conditioner is filSt turned on you need to allow lille t0Y the l OOlll to Coo1 dowll Cold air is escaping Check fi r open flu hate floor registel_ rod cold air l ettWllS Set the air conditioner s vent t the ch sed position Cooling coils have iced up Sue Ai conditioner freezing up below Air conditioner Ice blocks the air flow and On models with control knobs sot the mode control at freez...

Page 17: ...aining value of our contract No questions asked IVs that simple Protect yoltr refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge tor emeigency service and low monthly financing is available Even icemaker coverage and toed spoilage protection is offered You can rest easy knowing that all your valuable household products are protected against e...

Page 18: ...card with your product detach and return the form below to ensure that your product is registered or register online at ge com _Cm h r Consumer Product Ownership Registration Model Number Serial Number Mr Ms M s Miss Fil q I I L_slI Naln I I I I I I I I I Nalne I I I I I I I I I I I I Str el Addr ss I I I I I I I I I I I I I I I I I I I I I I I I Apt I I I E lnail Address 1 m Placed t holle _ _1 I...

Page 19: ...enm_ce Ji In commerciaJ locations labor necessary to move the unit to a location where it is accessible for service by m_ individual teclnficiml i_ Replacement of house fuses or resetting of circuit breakers _ Failure due to corrosion on models not corrosion protected Ji Dmnage to the product caused by improper power supply voltage accident fire floods or acts of God _ Incidental or consequentiaJ ...

Page 20: ...our warrant 00 _ __ is still in effect You can pro chase it on line an time or call 8 620 2224 dining normal business hours E Consumer Home Services will still be there after our warranl expires PartsandAccessories go cam Individuals qualified to sel _ ice their own appliances call have parts or accessories sent directly to their homes VISA MasterCard and Discover cards are accepted Order on line ...

Reviews: