background image

For answers to your Monogram,

® 

GE Profile

 or  

GE

®

 appliance questions, visit our website at 

ge.com or call GE Answer Center

®

 service,  

800.626.2000.

Specification Revised 12/07

230151

You must use the rear filler strip kit shipped with  

the range or the optional accessory backguard  

when installing these ranges
Note:

 Cabinets installed adjacent to slide-in  

ranges must have an adhesion spec of at least  
194° temperature rating.

Installation Information:

 Before installing, consult  

installation instructions packed with product for  
current dimensional data.

All GE ranges are equipped with 

an Anti-Tip device. The installation 

of this device is an important, 

required step in the installation  

of the range.

Dimensions and Installation Information (in inches) 

CGS980SEMSS 

GE Café

 

30" Free-Standing Gas Range

 

28-1/4*

36

Maintain 

at least 6" 

from nearest 

combustible 

surface.

Acceptable

Electrical

Outlet Area

30" Slide-In Range 

Dimensions (in inches)

45-1/8

2-1/4

5

6

4-1/2

30

30" Min.

15" Min.

6

30" Slide-in Elec. Range 

Aug. 8, 2003 -km

23-3/16

30

30

If you are NOT using the

Filler strip or Backguard:

If you are using the

Filler strip or Backguard:

25

*Wall to front of 

 closed door handle 

on model JSP34.

 28" on models 

 JSP26/JSS26/16.

Note: Range may be placed with 0" clearance (flush) at the back wall and side walls 

below countertop if the range side trims above the countertop extend beyond the cabinet 

fronts at least 1/4". (Self-clean models only.) Maintain at least 6" distance from nearest 

combustible surface.    

30

31-1/2

28-1/4*

36

Maintain 

at least 6" 

from nearest 

combustible 

surface.

Acceptable

Electrical

Outlet Area

30" Slide-In Range 

Dimensions (in inches)

45-1/8

2-1/4

5

6

4-1/2

30

30" Min.

15" Min.

6

30" Slide-in Elec. Range 

Aug. 8, 2003 -km

23-3/16

30

30

If you are NOT using the

Filler strip or Backguard:

If you are using the

Filler strip or Backguard:

25

*Wall to front of 

 closed door handle 

on model JSP34.

 28" on models 

 JSP26/JSS26/16.

Note: Range may be placed with 0" clearance (flush) at the back wall and side walls 

below countertop if the range side trims above the countertop extend beyond the cabinet 

fronts at least 1/4". (Self-clean models only.) Maintain at least 6" distance from nearest 

combustible surface.    

30

31-1/2

Counter Cutout Dimensions (in inches) 

30"

37-1/4"

26-1/4"

46-3/8"

36-1/4"

+_

1/4

9

30

2

4 4

24

13

14-1/2

2-1/2

Recommended area 

for thru the floor 

connection of pipe stub 

and shut-off valve

Recommended common 

area for gas outlet and 

electrical outlet

Recommended 

area for 120V outlet 

on rear wall and 

area for thru the 

wall connection 

of pipe stub and 

shut-off valve

30"

37-1/4"

26-1/4"

46-3/8"

36-1/4"

+_

1/4

9

30

2

4 4

24

13

14-1/2

2-1/2

Recommended area 

for thru the floor 

connection of pipe stub 

and shut-off valve

Recommended common 

area for gas outlet and 

electrical outlet

Recommended 

area for 120V outlet 

on rear wall and 

area for thru the 

wall connection 

of pipe stub and 

shut-off valve

Reviews: