A-14
C70 Capacitor Bank Protection and Control System
GE Multilin
A.1 PARAMETER LISTS
APPENDIX A
A
8251
SRC 3 Vb Harm[13]
%
Source 3 phase B voltage thirteenth harmonic
8252
SRC 3 Vb Harm[14]
%
Source 3 phase B voltage fourteenth harmonic
8253
SRC 3 Vb Harm[15]
%
Source 3 phase B voltage fifteenth harmonic
8254
SRC 3 Vb Harm[16]
%
Source 3 phase B voltage sixteenth harmonic
8255
SRC 3 Vb Harm[17]
%
Source 3 phase B voltage seventeenth harmonic
8256
SRC 3 Vb Harm[18]
%
Source 3 phase B voltage eighteenth harmonic
8257
SRC 3 Vb Harm[19]
%
Source 3 phase B voltage nineteenth harmonic
8258
SRC 3 Vb Harm[20]
%
Source 3 phase B voltage twentieth harmonic
8259
SRC 3 Vb Harm[21]
%
Source 3 phase B voltage twenty-first harmonic
8260
SRC 3 Vb Harm[22]
%
Source 3 phase B voltage twenty-second harmonic
8261
SRC 3 Vb Harm[23]
%
Source 3 phase B voltage twenty-third harmonic
8262
SRC 3 Vb Harm[24]
%
Source 3 phase B voltage twenty-fourth harmonic
8263
SRC 3 Vb Harm[25]
%
Source 3 phase B voltage twenty-fifth harmonic
8264
SRC 3 Vc THD
%
Source 3 phase C voltage total harmonic distortion (THD)
8265
SRC 3 Vc Harm[2]
%
Source 3 phase C voltage second harmonic
8266
SRC 3 Vc Harm[3]
%
Source 3 phase C voltage third harmonic
8267
SRC 3 Vc Harm[4]
%
Source 3 phase C voltage fourth harmonic
8268
SRC 3 Vc Harm[5]
%
Source 3 phase C voltage fifth harmonic
8269
SRC 3 Vc Harm[6]
%
Source 3 phase C voltage sixth harmonic
8270
SRC 3 Vc Harm[7]
%
Source 3 phase C voltage seventh harmonic
8271
SRC 3 Vc Harm[8]
%
Source 3 phase C voltage eighth harmonic
8272
SRC 3 Vc Harm[9]
%
Source 3 phase C voltage ninth harmonic
8273
SRC 3 Vc Harm[10]
%
Source 3 phase C voltage tenth harmonic
8274
SRC 3 Vc Harm[11]
%
Source 3 phase C voltage eleventh harmonic
8275
SRC 3 Vc Harm[12]
%
Source 3 phase C voltage twelfth harmonic
8276
SRC 3 Vc Harm[13]
%
Source 3 phase C voltage thirteenth harmonic
8277
SRC 3 Vc Harm[14]
%
Source 3 phase C voltage fourteenth harmonic
8278
SRC 3 Vc Harm[15]
%
Source 3 phase C voltage fifteenth harmonic
8279
SRC 3 Vc Harm[16]
%
Source 3 phase C voltage sixteenth harmonic
8280
SRC 3 Vc Harm[17]
%
Source 3 phase C voltage seventeenth harmonic
8281
SRC 3 Vc Harm[18]
%
Source 3 phase C voltage eighteenth harmonic
8282
SRC 3 Vc Harm[19]
%
Source 3 phase C voltage nineteenth harmonic
8283
SRC 3 Vc Harm[20]
%
Source 3 phase C voltage twentieth harmonic
8284
SRC 3 Vc Harm[21]
%
Source 3 phase C voltage twenty-first harmonic
8285
SRC 3 Vc Harm[22]
%
Source 3 phase C voltage twenty-second harmonic
8286
SRC 3 Vc Harm[23]
%
Source 3 phase C voltage twenty-third harmonic
8287
SRC 3 Vc Harm[24]
%
Source 3 phase C voltage twenty-fourth harmonic
8288
SRC 3 Vc Harm[25]
%
Source 3 phase C voltage twenty-fifth harmonic
8289
SRC 4 Va THD
%
Source 4 phase A voltage total harmonic distortion (THD)
8290
SRC 4 Va Harm[2]
%
Source 4 phase A voltage second harmonic
8291
SRC 4 Va Harm[3]
%
Source 4 phase A voltage third harmonic
8292
SRC 4 Va Harm[4]
%
Source 4 phase A voltage fourth harmonic
8293
SRC 4 Va Harm[5]
%
Source 4 phase A voltage fifth harmonic
8294
SRC 4 Va Harm[6]
%
Source 4 phase A voltage sixth harmonic
8295
SRC 4 Va Harm[7]
%
Source 4 phase A voltage seventh harmonic
8296
SRC 4 Va Harm[8]
%
Source 4 phase A voltage eighth harmonic
8297
SRC 4 Va Harm[9]
%
Source 4 phase A voltage ninth harmonic
Table A–1: FLEXANALOG DATA ITEMS (Sheet 14 of 33)
ADDRESS
FLEXANALOG NAME
UNITS
DESCRIPTION
Summary of Contents for C70
Page 10: ...x C70 Capacitor Bank Protection and Control System GE Multilin TABLE OF CONTENTS ...
Page 394: ...5 270 C70 Capacitor Bank Protection and Control System GE Multilin 5 10 TESTING 5 SETTINGS 5 ...
Page 676: ...E 10 C70 Capacitor Bank Protection and Control System GE Multilin E 1 OVERVIEW APPENDIX E E ...
Page 698: ...H 8 C70 Capacitor Bank Protection and Control System GE Multilin H 3 WARRANTY APPENDIX H H ...