Appendix A. CANopen Object Dictionary
28 | DPS 5000 Series Instruction Manual-English
© 2018 Baker Hughes, a GE company – All rights reserved.
A.1.17 Object 1800h to 1803h: Transmit PDO Communication
Parameter 1
It contains the communication parameters of the current PDO the device is able to transmit.
There are 4 PDOs available.
OBJECT DESCRIPTION
INDEX
1800 to 1803
Name
Transmit PDO Communication Parameter 1
Object Code
Record
Data Type
PDO_COMM_PAR
ENTRY DESCRIPTION
Sub-Index
000
Description
Number of Entries
Access
RO
PDO Mapping
No
Default Value
0x05
Sub-Index
001
Description
COB-ID
Data Type
UNSIGNED32
Access
RO
PDO Mapping
No
Default Value
0x00000180
Sub-Index
002
Description
Transmission Type
Data Type
UNSIGNED8
Access
RW
PDO Mapping
No
Default Value
0x1
A.1.18 Object 1A00h to 1A03h: Transmit PDO Mapping Parameter 1
Contains the mapping for the PDO the device is able to transmit. There are 4 PDOs available.
Sub-Index
Identity Object
0
Contains the number of PDO-parameters implemented.
1
Describes the COB-ID. If bit 31 is set the PDO is disabled. The
transmission mode is defined by sub-index 2. An inhibit time can
be defined on sub-index 3 in 100
μ
s. At the 5th sub-index can be
defined a event time for asynchronous PDO’s.