![GE b30 Technical Reference Manual Download Page 193](http://html1.mh-extra.com/html/ge/b30/b30_technical-reference-manual_4013170193.webp)
General Specifications
7-1
Document no. 2044677-001
1
General Specifications
1.1 Frame
Dimensions
Height
310 mm (12.2 in) Handle Up
280 mm (11 in) Handle Down
Width
310 mm (12.2 in) Without modules
350 mm (13.8 in) With modules
Depth
150 mm (5.9 in) Without extension module
160 mm (6.3 in) With extension module
210 mm (8.3 in) With extension and PSM modules
Weight
B30
5 kg
B30 without modules, batteries included
B30 + E-PSM(P)W
5.8 kg
B30 with WPSM
B30 + N-FCREC + E-PSM(P)W
6.8 kg
B30 with WPSM and extension module with recorder and CO
2
1.1.1 Electrical requirements
Any fluctuations within the specified limits do not affect the performance.
Mains input
Rated voltage
100 - 10% to 240
+
10% Vac
Rated frequencies
50/60Hz
Power consumption 150 VA
Ext. DC Input
Voltage 10
-
16V
Current
6 A max
1.1.2 Environmental requirements
Operating temperature
normal operation
5 to 40°C
41 to 104 °F
while charging batteries
5 to 35°C
41 to 95 °F
Storage temperature
-20 to +60°C
-4 to 140 °F
Relative humidity
10 to 90%. Non-condensing
Atmospheric pressure
670 to 1060 mbar (500 to 800 mmHg, 670 to 1060hPa)
1.2 LCD display
Display size
10.4 in (diagonal)
Display type
Active Matrix Color TFT LCD
Resolution
SVGA 800x600
Number of waveforms
Up to 6
Number of digit fields
Up to 4
Display layout and colors
User-configurable
Horizontal viewing angles
Left and right side 50°
Vertical viewing angles
Lower side 45°
Upper side 35°
Backlight lifetime
40 000h
Backlight intensity
250 Cd/m
2
typ.
Summary of Contents for b30
Page 2: ......
Page 12: ...B30 Patient Monitor 8 Document no 2044677 001...
Page 13: ...1 Introduction...
Page 14: ......
Page 61: ...2 Installation...
Page 69: ...3 Maintenance...
Page 70: ......
Page 105: ...4 Troubleshooting...
Page 106: ......
Page 125: ...5 Service Menu...
Page 126: ......
Page 158: ...B30 Patient Monitor 5 32 Document no 2044677 001...
Page 159: ...6 Field replaceable unit...
Page 160: ......
Page 166: ...B30 Patient Monitor 6 6 Document no 2044677 001 1 6 Frame for B30 Frame for B30...
Page 183: ...Frame disassembly 6 23 Document no 2044677 001...
Page 190: ...B30 Patient Monitor 6 30 Document no 2044677 001...
Page 191: ...7 Technical specification...
Page 192: ......
Page 198: ...B30 Patient Monitor 7 6 Document no 2044677 001...
Page 199: ...8 N F C REC Module...
Page 200: ......
Page 238: ...B30 Patient Monitor A 6 Document no 2044677 001...
Page 251: ......