AZ75E12DAC – GE Vertical Packaged Terminal Air Conditioner

Specification Created 8/02

GE Appliances

Minimum Clearances:

Front
• Allow 4 inches in front of unit. When determining closet depth, note that plenum

may protrude into closet up to 4 inches, depending on wall depth.

Sides

• Allow 3 inches on each side of unit.
• For side access closets only: Allow 5 inches on the side where access is required.

Platform 
• An 8"-12" high, field-supplied platform is recommended for drain access.

Overall Unit Dimensions

For answers to your Monogram,

®

GE Profile

or

GE appliance questions, visit our website at
GEAppliances.com or call 
GE Answer Center

®

service, 800.626.2000.

23 1/8” W

32 1/4” H

23 1/8” D

ZONELINE

®

WARRANTY

*

WHAT IS COVERED

FULL ONE-YEAR WARRANTY

For one year from date of original purchase,
we will provide, free of charge, parts and 
service labor on site to repair or replace

any part of the Zoneline

that fails

because of a manufacturing defect.

ADDITIONAL FOUR-YEAR WARRANTY

For an additional four years from the 
date of original purchase, we will provide, 
free of charge, parts and on-site service
labor to repair or replace 

any part of 

the sealed refrigerating system

(the 

compressor, condenser, evaporator and 
all connecting tubing) that fails because 
of a manufacturing defect.

*SEE WRITTEN WARRANTY FOR DETAILS

LIMITED 2ND THROUGH
5TH YEAR PARTS WARRANTY

For the second through the fifth year
from date of original purchase, General
Electric will provide, free of charge, parts
that fail as a result of a manufacturing
defect. Parts covered are fan motors,
switches, heater, heater protectors, 
compressor overload, solenoids, circuit
boards, auxiliary controls, thermistors,
frost controls, capacitors and varistors.
This is a limited parts-only warranty, and
does not include labor or transportation
to and from the service shop.

All warranty service will be provided by
our Factory Service Centers or by our
authorized Customer Care

®

servicers 

during normal working hours.

Power Connection Kit

RAK3152

RAK3202

RAK3302

Heater KW

2.55/2.09

3.45/2.82

5.00/4.09

Min. Circuit Amps

15

20

30

Recommended

15 Amp

20 Amp

30 Amp

Protective

Time Delay

Time Delay

Time Delay

Device

Fuse or Breaker

Fuse or Breaker

Fuse or Breaker

230/208 Volt

Line Cord Connected Units