Minimum Clearances:
Front
• Allow 4 inches in front of unit. When determining closet depth, note that plenum
may protrude into closet up to 4 inches, depending on wall depth.
Sides
• Allow 3 inches on each side of unit.
• For side access closets only: Allow 5 inches on the side where access is required.
Platform
• An 8"-12" high, field-supplied platform is recommended for drain access.
Overall Unit Dimensions
For answers to your Monogram,
®
GE Profile
™
or
GE appliance questions, visit our website at
GEAppliances.com or call
GE Answer Center
®
service, 800.626.2000.
23 1/8” W
32 1/4” H
23 1/8” D
ZONELINE
®
WARRANTY
*
WHAT IS COVERED
FULL ONE-YEAR WARRANTY
For one year from date of original purchase,
we will provide, free of charge, parts and
service labor on site to repair or replace
any part of the Zoneline
that fails
because of a manufacturing defect.
ADDITIONAL FOUR-YEAR WARRANTY
For an additional four years from the
date of original purchase, we will provide,
free of charge, parts and on-site service
labor to repair or replace
any part of
the sealed refrigerating system
(the
compressor, condenser, evaporator and
all connecting tubing) that fails because
of a manufacturing defect.
*SEE WRITTEN WARRANTY FOR DETAILS
LIMITED 2ND THROUGH
5TH YEAR PARTS WARRANTY
For the second through the fifth year
from date of original purchase, General
Electric will provide, free of charge, parts
that fail as a result of a manufacturing
defect. Parts covered are fan motors,
switches, heater, heater protectors,
compressor overload, solenoids, circuit
boards, auxiliary controls, thermistors,
frost controls, capacitors and varistors.
This is a limited parts-only warranty, and
does not include labor or transportation
to and from the service shop.
All warranty service will be provided by
our Factory Service Centers or by our
authorized Customer Care
®
servicers
during normal working hours.
Power Connection Kit
RAK3152
RAK3202
RAK3302
Heater KW
2.55/2.09
3.45/2.82
5.00/4.09
Min. Circuit Amps
15
20
30
Recommended
15 Amp
20 Amp
30 Amp
Protective
Time Delay
Time Delay
Time Delay
Device
Fuse or Breaker
Fuse or Breaker
Fuse or Breaker
230/208 Volt