If there is any doubt about X-radiation shields, not being in place or broken, the use of the EBM
Machine should be aborted immediately and Arcam EBM Service should be consulted.
C
Ca
au
uttiio
on
n
X-radiation (composed of X-rays) is emitted when the electrons accelerated in the column hit an-
other object.
When the Electron Beam Unit is in idle mode, no X-radiation is generated.
The EBM Machine is designed to keep X-radiation levels below limits indicated in EC Directive
96/29, EurAtom (1 µSv/hour).
To ensure satisfactory X-radiation protection all machine parts, internal and external must remain
in position. Removing or replacing parts such as; screws, bolts, metal plates or glass windows
might cause X-radiation leakage from the system.
C
Ca
au
uttiio
on
n
The system must NOT be modified by the user. Any modification can lead to X-radiation leakage
and must be checked by a radiation survey.
N
No
otte
e
It is the responsibility of the
end user
to perform the X-ray emission test on the Arcam EBM ma-
chine. This is done annually and after change of material type (metal powder).
Always
perform an X-ray test after change of material type (metal powder) in the EBM machine.
02
OM-710430
en-GB
25
Summary of Contents for ArcamEBM Spectra H
Page 1: ...Original language 02 OM 710430 en GB O OM M Operation Manual Spectra H...
Page 2: ...This page is intentionally left blank...
Page 4: ...Table of contents ii 02 OM 710430 en GB This page is intentionally left blank...
Page 6: ...Table of contents ii 02 OM 710430 en GB This page is intentionally left blank...
Page 8: ...This page is intentionally left blank 2 Revision Notes 4 02 OM 710430 en GB...
Page 24: ...5 Safety 412532 Jokab Safety Eden Eva 105261 Light curtain 20 02 OM 710430 en GB...