To be able to align the beam, the high voltage unit must be started.
A beam alignment is performed after a beam calibration or when the grid cup assembly (including the cath-
ode) is replaced. The beam can be aligned automatically or manually. It is recommended to let the machine
align the beam.
1. Press A
Alliig
gn
n B
Be
ea
am
m.
2. Press the F
Fo
occu
uss A
Alliig
gn
nm
me
en
ntt tab.
3. Verify the focus and the step size values. Default
values are:
S
Stte
ep
p ssiizze
e::
0.02
+
+F
Fo
occu
uss::
50
--F
Fo
occu
uss::
-50
4. Press +
+ to set the beam current to 0
0..6
6 tto
o 1
1..0
0 m
mA
A. If
needed the intensity of beam can be adjusted by
changing the beam current up or down.
5. Press S
Stta
arrtt to activate the beam. The focus offset
value now varies b
+5
50
0 m
mA
A a
an
nd
d --5
50
0 m
mA
A..
6. Wait for the indicator to turn green.
128
02
OM-710430
en-GB
Summary of Contents for ArcamEBM Spectra H
Page 1: ...Original language 02 OM 710430 en GB O OM M Operation Manual Spectra H...
Page 2: ...This page is intentionally left blank...
Page 4: ...Table of contents ii 02 OM 710430 en GB This page is intentionally left blank...
Page 6: ...Table of contents ii 02 OM 710430 en GB This page is intentionally left blank...
Page 8: ...This page is intentionally left blank 2 Revision Notes 4 02 OM 710430 en GB...
Page 24: ...5 Safety 412532 Jokab Safety Eden Eva 105261 Light curtain 20 02 OM 710430 en GB...