background image

Safety Instructions

 . . . . . . . . . . .2, 3

Operating Instructions

Controls  . . . . . . . . . . . . . . . . . . . .4, 5

Care and Cleaning

Air Filter  . . . . . . . . . . . . . . . . . . . . . .6
Front Grille . . . . . . . . . . . . . . . . . . . .7
Grille and Case . . . . . . . . . . . . . . . . .6
Outdoor Coils  . . . . . . . . . . . . . . . . .6

Installation Instructions

 . . . . .7–15

Troubleshooting Tips

 . . . . . . . . .16

Normal Operating Sounds  . . . . . .16

Consumer Support

Consumer Support  . . . . .Back Cover
Product Registration  . . . . . . . .17, 18
Warranty . . . . . . . . . . . . . . . . . . . . .19

49-7430

01-02 JR 

AKS05

AKV05

Air Conditioners

Owner’s Manual and

Installation Instructions

GEAppliances.com

Write the model and serial numbers here:

Model # __________________________

Serial # __________________________

Find these numbers on a label on the 
side of the air conditioner.

Summary of Contents for AKS05

Page 1: ...16 Normal Operating Sounds 16 Consumer Support Consumer Support Back Cover Product Registration 17 18 Warranty 19 49 7430 01 02 JR AKS05 AKV05 Air Conditioners Owner s Manual and Installation Instructions GEAppliances com Write the model and serial numbers here Model __________________________ Serial __________________________ Find these numbers on a label on the side of the air conditioner ...

Page 2: ... in the vicinity of this or any other appliance SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding plug which mates with a standard 3 prong grounding wall outlet to minimize the possibility of electric shock hazar...

Page 3: ... made to a properly grounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulling the power cord plug...

Page 4: ...it at least 3 minutes before switching back to a cool setting Cooling Descriptions For Normal Cooling Select HIGH COOL or MED COOL with the temp control at midpoint For Maximum Cooling Select HIGH COOL with the temp control at the highest number available on your knob For Quieter and Nighttime Cooling Select LOW COOL with the temp control at midpoint Temp Control The temp control is used to mainta...

Page 5: ...ressure on the horizontal louvers adjusts the air direction up or down Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions 5 GEAppliances com Additional controls and important information Vent Control on some models To open the vent push the lever to the right To close it push it to the left Air Direction Side to Side on some models The side t...

Page 6: ...ing the tab pull up slightly on the filter to release it and pull it down 2 1 Outdoor Coils The coils on the outdoor side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally steam cleaned a service available through your GE service outlet Grille and Case Turn the air conditioner off and remove the plug from the wall outlet before clea...

Page 7: ...power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Before You Begin Some models require 115 120 volt ac 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan t...

Page 8: ...sash seal Left accordion panel Type B 9 Window Installation Instructions 8 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Air conditioner case Accordion panel clamp 2 Bottom mounting rail Leveling bolt 2 Support bracket 2 Support rail 2 ...

Page 9: ...than the top of the storm window frame Attach securely with nails or screws provided by the installer 2 Read completely then follow step by step Window Requirements These instructions are for a standard double hung window You will need to modify them for other types of windows The air conditioner can be installed without the accordion panels if needed to fit in a narrow window See the window openi...

Page 10: ...d off NOTE Do not pull the bottom edge toward you more than 3 inches or you may damage the tabs of the grille Remove the two locking screws and locking brackets from the lower front of the unit Remove the screw securing the ground wire to the right side face of the unit Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case H G F E D C B ...

Page 11: ...d discard the shipping block next to the compressor 4 Remove and discard shipping block Install the Mounting Rails onto the Case Attach the top mounting rail onto the top of the case with 4 Type A screws Attach the bottom mounting rail to the bottom of the case from the inside using 4 Type A screws B A 5 Type A screws Type A screws Type A screws ...

Page 12: ...Top mounting rail Bottom mounting rail Accordion panel Prepare the Window Cut the window sash seal to the window width and stick the adhesive side to the bottom of the sash Mark the centerline of the stool Measure and mark the locations for the support assemblies 81 8 from both sides of the centerline B A 7 Window sash seal 81 8 Stool 81 8 Consumer Support Troubleshooting Tips Operating Instructio...

Page 13: ...utside edge of the sill NOTE Make sure that the leveling bolt will be firmly supported by the sill Tighten the Type A screws to secure the support bracket to the support rail in the correct position Repeat steps A E to assemble the second support F E D C B A 8 NOTE The support bracket may be attached into either slot in the support rail depending on the depth of your window sill Type A screws Supp...

Page 14: ... gaskets C B A Install the Case in the Window 14 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Window Installation Instructions Line up the V notches in the support rails with the left and right marks on the stool Make sure that the support rail is against the back of the stool and drill two 1 8 pilot holes into the stool through the hol...

Page 15: ...t push on the controls or the finned coils Make sure the air conditioner is firmly seated Reinstall the locking brackets and screws removed earlier IMPORTANT Reconnect the ground wire to the air conditioner Attach the front grille frame to the case by inserting the tabs on the grille frame into the slots on the front top of the case Push the grille frame in until it snaps into place around the pow...

Page 16: ...of the compressor overload Air conditioner does Airflow is restricted Make sure there are no curtains blinds or furniture not cool as it should blocking the front of the air conditioner The temp control may Turn the temperature knob to a higher number not be set correctly The air filter is dirty Clean the filter at least every 30 days See the Operating Instructions section The room may have been h...

Page 17: ...otection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that all y...

Page 18: ...ct is registered or register online at GEAppliances com 1 2 3 Model Number Serial Number Cut here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains information you will need should you require ser...

Page 19: ... provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caused by improper power supply voltage accident fire floods or acts of God Inc...

Page 20: ... warranty and learn about special discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly t...

Reviews: