background image

AKL05

AKN05
AKQ05

AKS05

AKV05
AKL06

AKN06
AKQ06

AKV06

Safety Instructions

 . . . . . . . .2, 3

Operating Instructions

Control Knob Models  . . . . . .6, 7
Touch Pad Models . . . . . . . . .4, 5

Care and Cleaning

Air Filter  . . . . . . . . . . . . . . . . . .8
Grille and Case  . . . . . . . . . . . . .8
Outdoor Coils  . . . . . . . . . . . . . .8

Installation Instructions

 . .9–17

Troubleshooting Tips

 . . .19, 20

Normal Operating Sounds  . . .20

Consumer Support

Consumer Support  . . . . . . . . .24
Product Registration  . . . . .21, 22
Warranty  . . . . . . . . . . . . . . . . .23

49-7452-1

12-02 JR

Owner’s Manual and

Installation Instructions

Write the model and serial numbers here:

Model # __________________________

Serial # __________________________

Find these numbers on a label on the
side of the air conditioner.

A

ir Condit

io

ners

Room

www.GEAppliances.com

Summary of Contents for AKL05

Page 1: ...Instructions 9 17 Troubleshooting Tips 19 20 Normal Operating Sounds 20 Consumer Support Consumer Support 24 Product Registration 21 22 Warranty 23 49 7452 1 12 02 JR Owner s Manual and Installation Instructions Write the model and serial numbers here Model __________________________ Serial __________________________ Find these numbers on a label on the side of the air conditioner Air Conditioners...

Page 2: ...aw must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grounding ...

Page 3: ...rounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulling the power cord plug with the other hand ...

Page 4: ...ill set the timer in hours OFF When the air conditioner is on it can be set to automatically turn off in 1 to 12 hours Each touch will set the timer in hours To cancel the timer press the TIMER pad until the display time disappears NOTE All timer settings are automatically cancelled if the unit is turned on or off after setting the timer Display Shows the room temperature set temperature or the ti...

Page 5: ...HIGH or MED fan with a middle set temperature For Maximum Cooling Select the COOL mode and HIGH fan with a lower set temperature For Quieter Nighttime Cooling Select the COOL mode and LOW fan with a middle set temperature NOTE If you switch from a COOL setting to OFF or to a fan setting wait at least 3 minutes before switching back to a COOL setting COOL Mode Use the FAN at HIGH MED or LOW to prov...

Page 6: ...ting Cooling Descriptions For Normal Cooling Select HIGH COOL or MED COOL with the temp control at midpoint For Maximum Cooling Select HIGH COOL with the temp control at the highest number available on your knob For Quieter and Nighttime Cooling Select LOW COOL with the temp control at midpoint Temp Controls on some models The temp control is used to maintain the room temperature The compressor wi...

Page 7: ...CLOSE only the air inside the room will be circulated and conditioned When set at OPEN some inside air is exhausted outside Vent Control Fingertip pressure on the horizontal louvers adjusts the air direction up or down Air Direction Up and Down The side to side air direction is adjusted by moving the air direction lever to the left or right Air Direction Side to Side on some models To open the ven...

Page 8: ...d the front grille should be checked and cleaned at least every 30 days or more often if necessary E1 in the display on models with touch pads is an automatic filter clean reminder Turn the air conditioner OFF and unplug it NOTE The air conditioner must be unplugged for the automatic filter clean timer to reset Clean the filter with warm soapy water Rinse and let the filter dry before replacing it...

Page 9: ...power cord Do not change the plug on the power cord of this air conditioner Aluminum house wiring may present special problems consult a qualified electrician Before You Begin Some models require 115 120 volt a c 60 Hz grounded outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan ...

Page 10: ...10 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Window installation instructions Parts Included Leveling bolt 2 Top mounting rail seal strip Bottom mounting rail Air conditioner case Top mounting rail Window locking bracket Locking bar 2 Type C 4 Nut 2 Left accordion panel Right accordion panel ...

Page 11: ...nry or metal The electrical outlet must be within reach of the power cord 1 14 min 22 to 351 2 With accordion panels 171 2 min Without accordion panels Storm Window Requirements A storm window frame will not allow the air conditioner to tilt towards the outside and will keep it from draining properly To adjust for this attach a piece of wood to the stool WOOD PIECES WIDTH 2 LENGTH Long enough to f...

Page 12: ...t down to remove Remove the three grille frame screws Grasp the lower corners of the grill frame while pressing in on the case sides with your finger tips Pull out to release and lift it up NOTE Do not pull the bottom edge toward you more than 3 or you may damage the tabs of the grille Remove the screw securing the ground wire to the left side of the face of the unit Slide the air conditioner from...

Page 13: ... the Case Remove the backing from the top mounting rail seal strip and attach it to the bottom of the top mounting rail Attach the top mounting rail onto the top of the case with 5 Type A screws Attach the bottom mounting rail to the bottom of the case from the inside using 2 Type A screws in the back holes of the bottom rail sides C B A 5 Remove and discard shipping pad Type A screws Type A screw...

Page 14: ...tom mounting rails Pull the shutter all the way out until the notch on the outside edge of the shutter is visible through the hole in the top corner of the frame Insert the notch on the shutter into the groove on the locking bar and slide the bar all the way down to secure the shutter Repeat steps A C for the right side accordion panel D C B A 6 Window installation instructions Prepare the Window ...

Page 15: ...ust the leveling bolts against the sill so that the supports had a slight tilt to the outside Use a level about 1 2 bubble will be the correct slant to the outside After leveling is done tighten the leveling bolt nut NOTE Use a steel washer between the leveling bolts and the sill if the sill is weak Extend the left and right accordion panels to the vertical window sashes Drill 1 8 pilot holes and ...

Page 16: ...and Install the Foam Top Window Gasket Drill a 1 8 pilot hole and attach the top mounting rail to the sash with a Type B screw Cut the foam top window gasket to the window width Stuff the foam between the glass and the window to prevent air and insects from getting into the room Attach the window locking bracket with 2 Type B screws D C B A Type B screw Top mounting rail 9 ...

Page 17: ...the case by inserting the tabs on the grille frame into the slots on the front top of the case Push the grille frame in until it snaps into place around the power cord on the right side Secure the front grille frame to the case by replacing the screws removed earlier Install the filter Hook the inlet grille in the frame and close it Connect power F E D C B A 10 Guide the levers carefully through t...

Page 18: ...18 Consumer Support Troubleshooting Tips Operating Instructions Safety Instructions Installation Instructions Notes ...

Page 19: ...onditioner is first turned on you need to allow time for the room to cool down Cold air is escaping Check for open furnace floor registers and cold air returns Set the air conditioner s vent to the closed position Cooling coils have iced up See Air conditioner freezing up below Air conditioner Ice blocks the air flow and On models with a temperature control knob set the freezing up stops the air c...

Page 20: ...ed turn the air conditioner back on If the code reappears call for service En appears Pipe temperature sensor Call for service in the display failure Er appears Room temperature sensor Call for service in the display failure Before you call for service Troubleshooting Tips You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidi...

Page 21: ... protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much more any brand Plus there s no extra charge for emergency service and low monthly financing is available Even icemaker coverage and food spoilage protection is offered You can rest easy knowing that al...

Page 22: ...sure that your product is registered or register online at www GEAppliances com 1 2 3 Model Number Serial Number Cut here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the registration below store this document in a safe place It contains information you will nee...

Page 23: ...cessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fuses or resetting of circuit breakers Failure due to corrosion on models not corrosion protected Damage to the product caused by improper power supply voltage accident fire floods or acts of God Incidental or consequential d...

Page 24: ... discounts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after your warranty expires Parts and Accessories www GEAppliances com Individuals qualified to service their own appliances can have parts or accessories sent directly to their homes VISA MasterCard...

Page 25: ...lemas 19 20 Sonidos normales de operación 20 Apoyo al consumidor Apoyo al consumidor 24 Garantía 23 49 7452 1 12 02 JR AKL05 AKN05 AKQ05 AKS05 AKV05 AKL06 AKN06 AKQ06 AKV06 Acondicionadores de Aire Manual del Propietario e Instrucciones de Instalación www GEAppliances com Escriba el modelo y número de serie aquí Número de modelo ______________ Número de serie ________________ Usted puede encontrar...

Page 26: ...frigerantes los cuales se deben retirar antes de la eliminación del producto de acuerdo con la ley federal Si va a desechar algún aparato antiguo de refrigeración consulte con la compañía a cargo de desechar el aparato para saber qué hacer PRECAUCIONES DE SEGURIDAD Bajo ninguna circunstancia corte o remueva la tercera púa tierra del cable eléctrico En pos de la seguridad personal este electrodomés...

Page 27: ... disponible en la mayoría de las ferreterías La ranura mayor en el adaptador debe estar alineada con la púa mayor en la pared para proporcionar una polaridad apropiada en la conexión del cable eléctrico Cuando se disponga a desconectar el cable eléctrico del adaptador siempre sostenga el adaptador en su lugar con una mano mientras tira del cable eléctrico con la otra mano Si no hace esto la termin...

Page 28: ...dor de aire está encendido puede ajustarse para que se apague automáticamente dentro de 1 a 12 horas Cada toque ajustará el tiempo en horas Para cancelar el sincronizador presione la tecla TIMER SINCRONIZADOR hasta que el tiempo en la pantalla desaparezca NOTA Todas las funciones del sincrinozidor son canceladas automáticamente si la unidad es apagada o encendida después de ajustar el sincronizado...

Page 29: ...enfriamiento silencioso y enfriamiento nocturno Seleccione el modo de ventilador COOL FRÍO y LOW BAJO con una temperatura de ajuste media NOTA Si cambia de un ajuste COOL FRÍO a OFF APAGADO o a un ajuste de ventilador espere aproximadamente 3 minutos antes de cambiar otra vez al ajuste de COOL FRÍO Dirección del aire Hacia arriba y hacia abajo Una presión sencilla con los dedos en las parrillas ho...

Page 30: ... de enfriamiento Para enfriamiento normal Seleccione HIGH COOL ENFRIAMIENTO ALTO o MED COOL ENFRIAMIENTO MEDIO con el control de temperatura en el medio Para enfriamiento máximo Seleccione HIGH COOL ENFRIAMIENTO ALTO con el control de temperatura en el número mayor disponible en su teclado Para enfriamiento silencioso durante la noche Seleccione LOW COOL ENFRIAMIENTO BAJO con el control de tempera...

Page 31: ...rección del aire hacia la izquierda o derecha Dirección del aire de lado a lado en algunos modelos El control de ventilación está localizado al interior de las parrillas de aire en el fondo de la ventanilla Cuando está ajustado en CLOSE CERRADO solamente el aire en el interior de la habitación circulará y se acondicionará Cuando está ajustado en OPEN ABIERTO un poco del aire interno es expelido ha...

Page 32: ...edad y las pelusas lo obstruirán y reducirán su rendimiento Para retirar Hale hasta liberar las esquinas inferiores de la rejilla de entrada y luego levántela y retírela Utilizando la lengüeta hale el filtro ligeramente hacia arriba para liberarlo y luego hale hacia abajo para retirarlo 2 1 Bobinas para exteriores Las bobinas en el lado exterior del acondicionador de aire debe ser inspeccionada re...

Page 33: ...les Consulte a un técnico calificado Antes de comenzar Algunos modelos requieren tomacorrientes de 115 120 voltios de corriente alterna y 60 Hz conectados a tierra protegidos con un fusible de dilatación de tiempo de 15 amperios o un cortacircuitos El enchufe de tres púas con conexión a tierra minimiza la posibilidad de descargas eléctricas Si el tomacorriente de la pared que usted planea usar sol...

Page 34: ...ciones para la instalación en una ventana Partes incluidas Cinta de sellado del riel de montaje superior Riel de montaje inferior Caja del acondicionador de aire Riel de montaje superior Soporte para bloqueo de ventana Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación Tipo C 4 Tornillo de ajuste 2 Barra de cierre 2 Tuerca 2 Panel de acordeón derecho Marco del panel de acorde...

Page 35: ...r 2 Lea completamente luego siga paso por paso Requisitos para la ventana Estas instrucciones son para una ventana estándar de dos pliegues Usted necesitará modificar el proceso para otros tipos de ventanas El acondicionador de aire puede instalarse sin los paneles de acordeón para ajustarse a una ventana más estrecha Ver las dimensiones de la abertura de la ventana Todas las partes de apoyo deben...

Page 36: ...s costados de la caja con las puntas de los dedos Hale hacia afuera para liberarlo y después levántelo NOTA No hale el borde inferior hacia usted más de 3 pulgadas 76 mm o podría dañar las lengüetas de la rejilla Retire el tornillo que sujeta el cable de conexión a tierra con la pared lateral izquierda de la unidad Deslice el acondicionador de aire de la caja agarrando la manija del recipiente de ...

Page 37: ...del riel de montaje superior y únala a la parte inferior del riel de montaje superior Una el riel de montaje superior a la parte superior de la caja con 5 tornillos tipos A Una el riel de montaje inferior a la parte inferior de la caja desde el interior usando 2 tornillos tipos A in los agujeros posteriores de los lados de los rieles inferiores C B A 5 Retire y deseche el bloque de empaque Tornill...

Page 38: ...or en la ranura del costado frontal izquierdo de la caja Deslice el disparador completamente en la ranura Deslice el panel de acordeón izquierdo sobre los rieles de montaje superiores e inferiores Tire del disparador completamente hasta que la muesca en el extremo exterior del disparador esté visible a través del agujero en la esquina superior del marco Inserte hacia abajo la muesca en el disparad...

Page 39: ...hacia afuera Use un nivel aproximadamente media burbuja será la inclinación correcta hacia el exterior Después de nivelación apriete la tuerca del tornillo de ajuste NOTA Use una arandela de acero entre los tornillos para nivelar y el umbral si el umbral es débil Extienda los paneles de acordeón izquierdo y derecho hasta las pestañas verticales de la ventana Taladre agujeros pilotos de 1 8 y pegue...

Page 40: ...erior al marco con un tornillo tipo B Corte el empaque superior de espuma de la ventana al ancho de la ventana Rellene la espuma entre el cristal y la ventana para evitar que el aire y los insectos entren al cuarto Una el soporte de seguridad de la ventana con dos tornillos tipo B D C B A 9 Tornillo tipo B Riel de montaje superior Apoyo al consumidor Solucionar problemas Operación Seguridad Instal...

Page 41: ...o las lengüetas en el marco de la rejilla dentro de las ranuras de la pared superior frontal de la caja Empuje el marco de la rejilla hasta que quede en su lugar alrededor del cable eléctrico en el lado derecho Asegure el marco de la rejilla frontal en la caja reemplazando los tornillos removidos anteriormente Instale el filtro Enganche la rejilla de entrada en el marco y ciérrelo Conecte la energ...

Page 42: ...Notas Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación 18 ...

Page 43: ...modo COOL FRÍO está ajustado apropiadamente presione la tecla DECREASE En los modelos con un boton de temperatura gire la temperatura a un número mayor El filtro de aire está sucio Limpie el filtro cada 30 días por lo menos Ver la sección de Instrucciones de operación La habitación podría haber Cuando el acondicionador de aire se enciende usted estado caliente necesita darle tiempo para que enfrié...

Page 44: ...pieza Después de la limpieza vuelva a instalar el filtro y conecte nuevamente el acondicionador de aire Ed aparece Protección contra Apague el acondicionador de aire Espere por lo menos en la pantalla el congelamiento 3 minutos y vuelva a encender el acondicionador de aire activada automáticamente Si el código vuelve a aparecer llame para solicitar servicio En aparece Falla en el sensor de tempera...

Page 45: ...21 Notas Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación ...

Page 46: ...22 Notas Apoyo al consumidor Solucionar problemas Operación Seguridad Instalación ...

Page 47: ... necesario En locales comerciales la mano de obra necesaria para retirar la unidad hacia un lugar para revisión por parte de un técnico individual Reemplazo de fusibles de la casa o reajuste del sistema de circuitos Fallos debido a la corrosión en modelos que no están protegidos contra la corrosión Daño al producto causado por voltaje inapropiado hacia el equipo accidentes incendios inundaciones o...

Page 48: ... detalles sobre descuentos especiales disponibles mientras su garantía está aún activa Puede comprarla en línea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services estará aún ahí cuando su garantía termine Piezas y accesorios www GEAppliances com Aquellos individuos con la calificación necesaria para reparar sus propios electrodomésticos pueden...

Reviews: