Summary of Contents for AJCM Series and

Page 1: ... STAR guidelines for energy efficiency Write the model end serial numbers here Model Seria Find these numbers on a label on the front of the base pan behind the front grille Cool Only Heat Cool AJCM 08 i0 ACD AJCM i0 12 DCD AJCQ 06 LCD AJCQ 08 20 12 ACD AJCQ 09 20 22 DCD AJEM 22 DCD AJEQ 06 LCD AJEQ 08 ACD AJEQ 09 20 22 DCD Espafiol For a Spanish version of this manual visit our Website at GEAppli...

Page 2: ...nts check with the company handling disposal about what to do HOW TO CONNECT ELECTRICITY AWARNING nisk ofelectric shock Can cause injury or death This appliance must be properly grounded Do not under any circumstances cut or remove the third ground prong from the power cord For personal safety this appliance must be properly grounded The power cord of this appliance is equipped with a 3 prong grou...

Page 3: ...ng wall outlet by use of a UL listed adapter available at most local hardware stores iiiiiiiiiiii_i i The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide proper polarity in the connection of the power cord iiiiiiiiiiii_i i When disconnecting the power cord from the adapter always hold the adapter in place with one hand while pulling the power cord plug...

Page 4: ...then in hours up to 24 To cancel the On Timer pressthe ON pad until the display time disappears OFF When the air conditioner is on it can be set to automatically turn off in half an hour to 2 4hours Eachtouch will set the time in half hours up to 0 and then in hours up to 24 To cancel the Off Timer pressthe OFFpad until the display time disappears SLEEP Pressto set the air conditioner to run for 8...

Page 5: ...rconditionerisoff andisthenturnedon whilesetto COOL it will takeapproximately 3minutes for the compressor to start andcoolingto begin Cooling Descriptions For NormalCooling Selectthe COOLmodeandHIGH or MEDfan witha middlesettemperature For Maximum Cooling Select the COOL mode and HIGHfan with a lower set temperature For Quieterand NighttimeCooling Selectthe COOL modeand LOWfanwith a middlesettempe...

Page 6: ...et to automatically turn on in half an hour to 24 hours at its previous setting Eachtouch will setthe time in half hours up to 10 and then in hours up to 24 To cancel the OnTimer press the ON pad until the display time disappears OFF When the air conditioner is on it can be set to automatically turn off in half an hour to 24 hours Each touch will set the time in half hours up to 10 and then in hou...

Page 7: ...dfan speed 3 Press the INCREASE DECREASE padsto setthe desiredtemperature60 Fto 85 Fin I F increments ControlPanel 1 Press the MODE pad untilthe HEAT indicatorlightis lit 2 Press the FANpaduntilHIGHor LOWindicatorlight is litfor desiredfan speed 3 Press the INCREASE DECREASE padsto setthe desiredtemperature60 Fto 85 Fin I F increments Athermostatis usedto maintainthe roomtemperature Thecompressor ...

Page 8: ...controls are located behind the room cabinet as shown in this figure The owner is responsiblefor checking switches and ensuring they are in the desired position FanCycle Continuous Cool X FanCycle Continuous Heat onsomemodels _ Class 2 onsomemodels I Nofunction reserved r UP forfuture use Fan Cycle Continuous Coo When this switch is enabled UP it allows the indoor fan to cycle on off with the comp...

Page 9: ...nnected the unit will be controlled by remote thermost t NOTE The number 3 dip switch must be in the en bled UPJ position to ctiv te the remote thermost t Seethe inst ll tion instructions supplied with the remote thermost t Terminal onnectlons location nderfront grille __ IMPORTANT The thermost t connections provide 24 V AConly If using digit l electronic w ll thermost t ensure it is comp tible wi...

Page 10: ...ot they may be professionally steam cleaned a service available through your GEservice outlet Front Grille The front grille can be removed for more thorough cleaning and to locate the model and serial numbers on the front of the base pan To remove 1 Pullthe filter out 2 Removethe two grille screws Onsomemodels t 3 Pullthe grille out from the bottom and lift up from the tabs on the top of the case ...

Page 11: ... tab forward up and out To replace the air filter Replace the clean filter by pushing it back into place N0 7 1CE 00 not operate the air conditioner without the filter in place If a filter becomes torn or damaged it should be replaced immediately Operating without the filter in place or with a damaged filter will allow dirt and dust to reach the indoor coil and reduce the cooling heating airflow a...

Page 12: ...m house wiring may present special problems consult a qualified electrician Cb ELECTRICALREQUIREMENTS cont Some models require 230 208 volt a c protected with a time delay fuse or circuit breaker These modelsshould be installedon their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits which could cause a possiblefire hazard from overheatin...

Page 13: ...072 RAK1082 RAKl102 RAK123A64 Hotpoint ACXBIO ii ACTB Chassis Whirlpool Type 23W Wall Case GE RAB30 F models Adapts an older Hotpoint wall case to a J model chassis Fits Hot_point wall cases 25s 4 W x 167 8 Hx 18s 8 D Adapts Whirlpool wall case to a J model chassis Fits Whirlpool wall cases 2578 W x 16 H x 23 D Adapts GE wall case to a J model chassis Fits the RAB 30 wall case 26 W x 18 H x 24 D F...

Page 14: ...IDE AIR CONDITIONER NEXT TO COMPRESSOR Remove shipping pads if present REINSTALL LOCKING PLATE WITH TAB BEHIND WALL CASE FLANGE TIGHTEN SCREW r_ ATTACH POWER CORD TO BASE PAN WITH CLAMP pan F6 ATTACH FRONT GRILLE An opening for the power cord is on the bottom of the front grille 131 CAREFULLY SLIDE AIR CONDITIONER BACK INTO CASE Make sure that the tubing on the unit does not touch the wall case an...

Page 15: ...hed sides of the opening should be structural wall members Lintel Use a lintel in brick veneer and brick and block types of wall to support the bricks or blocks above the opening Do not allow the wall case to be used in lieu of a lintel Flashing Install flashing drip rail as shown to prevent water from dripping inside the wall and down the outside of the building Brick Lintelan if required Plaster...

Page 16: ...windowgasket Window __ Iocl ing bracket TypeA 9 TypeB 2 TypeC painted 6 TypeD 2 TypeE 4 Support brackethardware Spacer 2 Loci nut 2 Adjustingbolt 2 Largewasher 2 r_ WINDOW REQUIREMENTS These instructions are for a standard double hung window You will need to modify them for other types of windows The air conditioner can be installed without the accordion panels if needed to fit in a narrow window ...

Page 17: ...g screw on the back of the air conditioner to allow removal of the air conditioner from the case Remove screw r_ Pull the bottom corners of the air conditioner and slide it out of the case r_ Removeall shipping pads if present inside the air conditioner next to the compressor re Remove shipping pads if present Remove the rear grille that is taped to the back of the case Remove the packet of screws...

Page 18: ...he bolts and tighten the lock nuts to make the sill supports level or tilt down 1 8 to the outside Line up the V notch with 123A marks Drill pilot holes and attach the sill supports Average sill Sillsupport _iT Spacer Narrowsill Offsetsill suchasbrickorstone FB1 Before attaching the sill supports place them on the window stool Select the spacer position that will place the spacer near the outermos...

Page 19: ...nter piece Note position of the notches B Right side dz FillerPanels Cutpanels anddiscard center piece i A ILeftside i 03 o 03 e Put together the panel assemblies Remove the paper backing from the case side gasket and attach it to the angle Push a pencil point through the gaskets to locate the holes in the angles Gasket Tab s Angle TypeC painted screws rD Install the panels in the window Place the...

Page 20: ... fits behind the panel tabs Insert the 4 type A screws through the holes in the case and into the panel angles 2 on each side tabs Case screws With the window closed mark where the window sash meets the case Peel off the backing from the case top gasket Hold on to the case open the window and place the gasket along the mark on the case Putthegasketon topof thecase wherethewindow will close Place t...

Page 21: ...ocking bracket with 1 type E screw 1 t r_ REPLACE AIR CONDITIONER IN CASE r_ carefully slide the air conditioner back into the case FB1Attach the power cord to the base pan with the clamp pan ro 1Reinstall the locking plate with the tab behind the wall case flange Tighten the screw Reattach the front grille An opening for the power cord is on the bottom of the front grille r_ Fill holes and cracks...

Page 22: ...ir isescaping Checkfor openfurnaceregistersandcoldairreturns Hakesurethe airconditioner s vent isinthe closedposition Coolingcoilshaveicedup See Airconditionerfreezingup below Air conditioner Ice blocks the airflow Set the controls at HIGHFANor HIGHCOOLand set the freezingup and stopsthe air conditioner thermostatto a highertemperatureto allowthe iceto melt from cooling the room Theremotecontrolis...

Page 23: ...nable use including failure to provide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician iiiiiiiiiiii_iii Replacement of house fuses or resetting of circuit breakers Failure due to corrosionon models not corrosion protected Damage to the product caused by improper power supply v...

Page 24: ...ble while your warranty is still ineffect You can purchase it on line anytime or call 800 626 2224during normal business hours GEConsumer Home Serviceswill still be there after your warranty expires Parts and Accessories GEAppliunces com Individuals qualified to service their own appliances can have parts or accessoriessent directly to their homes VISA HasterCard and Discovercards are accepted Ord...