Problem

Possible Causes

What To Do

Air conditioner

The air conditioner

Make sure the air conditioner plug is pushed completely

does not start

is unplugged.

into the outlet.

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

breaker is tripped.

the fuse or reset the breaker.

Power failure.

If power failure occurs, turn the air conditioner 

OFF

.

When power is restored, wait 3 minutes to restart the
air conditioner to prevent tripping of the compressor 
overload.

Air conditioner does not

Airflow is restricted.

Make sure there are no curtains, blinds or furniture

cool as it should

blocking the front of the air conditioner.

The temp control may not

In 

COOL

mode, press the 

DECREASE

pad. 

be set correctly.

The air filter is dirty.

Clean the filter at least every 30 days.
See the 

Operating Instructions

section.

The room may have been hot.

When the air conditioner is first turned on, you need to
allow time for the room to cool down.

Cold air is escaping.

Check for open furnace floor registers and cold air
returns.

Set the air conditioner’s vent to the closed position.

Cooling coils have iced up.

See “

Air conditioner freezing up

” below.

Air conditioner

Ice blocks the air flow and

Set the controls at 

HIGH (F3) FAN 

or 

HIGH (F3) COOL 

and

freezing up

stops the air conditioner

set the thermostat to a higher temperature.

from cooling the room.

The remote control  

The batteries are inserted

Check the position of the batteries. They should be 

is not working

incorrectly.

inserted in the opposite (+) and (–) direction.

The batteries may be dead.

Replace the batteries.

Water drips outside

Excessively hot and

This is normal.

humid weather.

Water drips indoors

The air conditioner is not

For proper water disposal, make sure the air conditioner

tilted to the outside.

slants slightly from the case front to the rear.

Water collects in 

Moisture is removed from 

This is normal for a short period in areas with little

base pan

indoor air and drains into

humidity; normal for a longer period in very humid areas.

rear of a cabinet where a fan
blows it against the outdoor
condenser coil.

TIMER feature not 

A power outage or interruption 

In the case of a power outage or interruption, the unit  

working properly

occurred.

TIMER

feature will reset to the original setting. You may 

need to set a new time if desired.

Troubleshooting Tips

www.GEAppliances.com

Troubleshooting Tips. 
Save time and money! Review the chart below first and
you may not need to call for service.

Summary of Contents for AGW12

Page 1: ...ion 8 12 Troubleshooting Tips 13 Normal Operating Sounds 14 Consumer Support Consumer Support 18 Product Registration 15 16 Warranty 17 49 7477 11 03 JR Owner s Manual and Installation Instructions Wr...

Page 2: ...w must be removed prior to product disposal If you are getting rid of an old product with refrigerants check with the company handling disposal about what to do SAFETY PRECAUTIONS Do not under any cir...

Page 3: ...ounded 2 prong wall outlet by use of a UL listed adapter available at most local hardware stores The larger slot in the adapter must be aligned with the larger slot in the wall outlet to provide prope...

Page 4: ...t the air conditioner to COOL or FAN mode FAN Pad Use to set the fan speed to LOW F1 MED F2 or HIGH F3 TIMER Pad ON When the air conditioner is off it can be set to automatically come on in 1 to 12 ho...

Page 5: ...ooling Select the COOL mode and HIGH F3 or MED F2 fan with a middle set temperature For Maximum Cooling Select the COOL mode and HIGH F3 fan with a lower set temperature For Quieter Nighttime Cooling...

Page 6: ...ged with dirt or soot they may be professionally steam cleaned a service available through your GE service outlet Outdoor Coils The air filter behind the front grille should be checked and cleaned at...

Page 7: ...ed outlet protected with a 15 amp time delay fuse or circuit breaker The 3 prong grounding plug minimizes the possibility of electric shock hazard If the wall outlet you plan to use is only a 2 prong...

Page 8: ...cket Right accordion panel Foam top window gasket Window sash seal Left accordion panel Type B 3 Type C 5 Bolt 2 Nut 2 Frame guide 2 Top mounting rail seal strip Top mounting rail PARTS INCLUDED Appea...

Page 9: ...e will not allow the air conditioner to tilt toward the outside and will keep it from draining properly To adjust for this attach a piece of wood to the stool WOOD PIECES WIDTH 2 LENGTH Long enough to...

Page 10: ...and attach the seal to the underside of the window sash A 4 PREPARE THE WINDOW AND THE CASE CONT Carefully insert the plastic frame guides into the bottom of the case on each side Remove the backing f...

Page 11: ...nt on the sill Attach the sill supports to the case track hole in relation to the selected position using 2 type A screws in each support E D C B A 5 Installation Instructions Bolt Nut Sill support OU...

Page 12: ...grille Raise the inlet grille back into place D C B Installation Instructions INSTALL THE WINDOW LOCKING BRACKET AND THE FOAM TOP WINDOW GASKET Attach a support bracket with a Type C screw Cut the fo...

Page 13: ...closed position Cooling coils have iced up See Air conditioner freezing up below Air conditioner Ice blocks the air flow and Set the controls at HIGH F3 FAN or HIGH F3 COOL and freezing up stops the a...

Page 14: ...ainst the condenser on rainy days or when the humidity is high This design feature helps remove moisture and improve efficiency You may hear the thermostat click when the compressor cycles on and off...

Page 15: ...protection or you may request your money back on the remaining value of your contract No questions asked It s that simple Protect your refrigerator dishwasher washer and dryer range TV VCR and much mo...

Page 16: ...er Cut here Complete and mail your Consumer Product Ownership Registration today Have the peace of mind of knowing we can contact you in the unlikely event of a safety modification After mailing the r...

Page 17: ...vide reasonable and necessary maintenance In commercial locations labor necessary to move the unit to a location where it is accessible for service by an individual technician Replacement of house fus...

Page 18: ...nts that are available while your warranty is still in effect You can purchase it on line anytime or call 800 626 2224 during normal business hours GE Consumer Home Services will still be there after...

Page 19: ...ionador de aire 7 Solucionar problemas 13 Sonidos normales de operaci n 14 Apoyo al consumidor Apoyo al consumidor 18 Garant a 17 49 7477 11 03 JR Manual del propietario e Instrucciones de Instalaci n...

Page 20: ...es los que por Ley Federan deben ser removidos antes de desecharlos Si usted planea deshacerse de alg n producto que contenga refrigerantes p ngase en contacto con la compa a que se encarga de recoger...

Page 21: ...da con la p a mayor en la pared para proporcionar una polaridad apropiada en la conexi n del cable el ctrico Cuando se disponga a desconectar el cable el ctrico del adaptador siempre sostenga el adapt...

Page 22: ...e encienda autom ticamente dentro de 1 a 12 horas en el nivel previo Cada toque ajustar el tiempo en horas OFF APAGADO Cuando el acondicionador de aire est encendido puede ajustarse para que se apague...

Page 23: ...a enfriamiento silencioso y enfriamiento nocturno Seleccione el modo de ventilador COOL y LOW F1 BAJO con una temperatura de ajuste media NOTA Si cambia de un ajuste COOL FR O a OFF APAGADO o a un aju...

Page 24: ...ervicios Bobinas para exteriores El filtro de aire detr s de la rejilla frontal debe inspeccionarse y limpiarse por lo menos cada 30 d as o m s a menudo si fuese necesario Para retirarlo Abra la rejil...

Page 25: ...dio por el sobrecalentamiento de los alambres REQUISITOS EL CTRICOS PRECAUCI N Bajo ninguna circunstancia corte o remueva la tercera p a conexi n a tierra del cable el ctrico No cambie el enchufe en e...

Page 26: ...superior de la espuma de la junta de la ventana Banda de sello de la ventana Panel de acorde n izquierdo Tipo B 3 Tipo C 5 Tornillo 2 Tuerca 2 Gu a del marco 2 Cinta de sellado del riel de montaje sup...

Page 27: ...rco de ventana de tormentas no permitir que el acondicionador de aire se incline hacia el exterior y evitar que drene apropiadamente Para solucionar este problema adhiera un pedazo de madera a la repi...

Page 28: ...ior de la banda de sellado del riel de montura superior y nala al fondo del riel de montaje superior Instale el riel de montaje superior con 3 tornillos tipo A en el interior de la caja Inserte los ma...

Page 29: ...en el umbral Una los soportes del umbral al agujero de trayectoria de la caja en relaci n con la posici n seleccionada usando dos tornillos tipo A en cada soporte E D C B A 5 Tornillo Tuerca Soporte d...

Page 30: ...a de control de ventilaci n localizada encima de los botones de control de la unidad como se muestra Una la parrilla del frente a la caja insertando las orejillas en la parrilla en las ranuras en el f...

Page 31: ...nador de aire El hielo bloquea el flujo Coloque los controles en HIGH F3 FAN VENTILADOR se est congelando de aire hacia el acondicionador ALTO o HIGH F3 COOL FR O ALTO y coloque el de aire evitando qu...

Page 32: ...ora la eficiencia Quiz s escuche que el termostato hace clic cuando el compresor hace ciclo entre encendido y apagado El agua se acumula en la bandeja durante d as lluviosos o con mucha humedad El agu...

Page 33: ...15 Apoyo al consumidor Solucionar problemas Operaci n Seguridad Instalaci n Notas www GEAppliances com...

Page 34: ...16 Notas Apoyo al consumidor Solucionar problemas Operaci n Seguridad Instalaci n...

Page 35: ...io En locales comerciales la mano de obra necesaria para retirar la unidad hacia un lugar para revisi n por parte de un t cnico individual Reemplazo de fusibles de la casa o reajuste del sistema de ci...

Page 36: ...entos especiales disponibles mientras su garant a est a n activa Puede comprarla en l nea en cualquier momento o llamar al 800 626 2224 durante horas normales de oficina GE Consumer Home Services esta...

Reviews: