GE 8RP Board Installation Sheet Download Page 1

 

1 of 6 

P/N 460235001J • ISS 21MAR08 

GE 

Security 

 

8RP Board

 

Installation Sheet

 

 

Introduction 

This installation sheet is designed to help experienced 
technicians install the 8RP Board quickly. For more detailed 
information, refer to the appropriate controller installation 
manual. 

The number of 8RP Boards supported by different host 
software systems varies. Consult the manual that came 
with your software for this information. 

Features include:  

•  Each 8RP Board is limited to only one type of reader 

technology: F/2F or supervised F/2F.  

•  External pull-up resistors are not required for the 8RP 

Board. 

•  No door DI (alarm) or exit DI points are available on the 

8RP Board. Use of supervised readers is recommended 
since these points are available on the reader. 

•  If keypad readers are needed, use only GE supervised 

F/2F keypad readers or Wiegand Interface Units (WIU-
2/WIU-4). 

•  Each reader, reader-based DI (input) point, and reader-

based exit DI on the 8RP Board is addressed differently 
depending on the host system you are using.  

•  The 8RP Board provides one digital output (reader LED) 

per reader port, 12 VDC, 100 mA maximum per output 
point. 

Verify contents 

Caution: 

While the 8RP has been designed to resist 

electrostatic damage (ESD), it can be damaged by such 
discharges. Always observe proper ESD precautions when 
handling and storing the 8RP. 

Inspect the package and contents for visible damage. If any 
components are damaged or missing, do not use the unit; 
contact the supplier immediately. If you need to return the 
unit, you must ship it in the original box.  

The package should include the following contents: 

•  8RP Reader Board 
•  8RP Board Installation Sheet (this document) 
•  1N4004A protection diodes 
• MOV 

varistors 

•  8-position, 45-degree connectors 

Figure 1: 8RP Board layout 

 

Summary of Contents for 8RP Board

Page 1: ...ded use only GE supervised F 2F keypad readers or Wiegand Interface Units WIU 2 WIU 4 Each reader reader based DI input point and reader based exit DI on the 8RP Board is addressed differently depending on the host system you are using The 8RP Board provides one digital output reader LED per reader port 12 VDC 100 mA maximum per output point Verify contents Caution While the 8RP has been designed ...

Page 2: ...r 11 and 12 Reader 13 and 14 Reader 15 and 16 Picture Perfect board number 5 6 7 8 Readers 0 and 1 0 and 1 0 and 1 0 and 1 Door DIs 0 and 1 0 and 1 0 and 1 0 and 1 Exit DIs 8 and 9 8 and 9 8 and 9 8 and 9 Door DOs 0 and 1 0 and 1 0 and 1 0 and 1 1 The second 8 readers out of 16 See Table 5 for board type settings Facility Commander Wnx and Secure Perfect The Facility Commander Wnx and Secure Perfe...

Page 3: ...ions cable shield to the ground nut adjacent to the cable entrance knockout of the cabinet enclosure For more details see Figure 2 Caution The 8RP Board has built in pull up resistors Do not install the external pull up resistors supplied with the GE Proximity Readers 4 Depending on your configuration attach the appropriate wires to the appropriate screw terminal on the 8RP Board as shown in Figur...

Page 4: ...all a protection diode across the relay and the door strike Use 1N4002 1N4003 1N4004 or equivalent diodes for DC door strikes and Metal Oxide Varistors MOV for AC door strikes See Figure 3 4 Protection diode or MOV and blocking diode are required at all electronic door locks 5 Install a blocking diode on the door DO Reader LED line between the reader and the door strike relay Use 1N5817 diode whic...

Page 5: ...P N 460235001J ISS 21MAR08 5 of 6 Figure 4 Powering two 8RP Boards Figure 5 Wiring 8RP to WIU 4 Wiegand readers ...

Page 6: ... AWG shielded pairs Operating environment Temperature Humidity 35 to 122 F 2 to 50 C 5 to 95 RH noncondensing at 90 F 32 C Contacting customer support You can reach customer support by phone from 8 a m to 7 p m EST Monday through Friday GE Security United States 1 888 GE SECURITY 1 888 437 3287 Asia 852 2907 8108 Australia 61 3 9259 4700 Europe 48 58 326 22 40 Latin America 305 593 4301 ...