5–14
845 TRANSFORMER PROTECTION SYSTEM – INSTRUCTION MANUAL
INFORMATION
CHAPTER 5: STATUS
Hardware Versions
Path
:
Status > Information > Hardware Versions
The Information related to the relay hardware is displayed here.
Figure 5-7: Information for Hordware Versions
•
FPGA Firmware Version:
The firmware version of the FPGA
•
IO F CPLD:
The version of the CPLD in IO slot F
•
IO G CPLD:
The version of the CPLD in IO slot G
•
AN J CPLD:
The version of the CPLD in analog slot J
•
AN K CPLD:
The version of the CPLD in analog slot K
•
Display CPLD:
The version of the CPLD of the display
Environment
The Information related to Environmental is displayed here.
Path
:
Status > Information > Environment
•
Instantaneous Temperature:
The most recent temperature measurement taken by
the EAM.
•
Firmware Version:
The software version of the EAM module found in the relay.
•
Last Poll Date/ Time:
The date and time on which the last measurements were
recorded in the format MM/DD/YY and HH/MM/SS.
•
Average Humidity:
The average of all the humidity measurements taken over time
(last 1 hr) by the EAM.
•
Maximum Humidity:
The maximum humidity measurement taken by the EAM since it
began recording data.
•
Minimum Humidity:
The minimum humidity measurement taken by the EAM since it
began recording data.
•
Average Ambient Temp:
The average of all the instantaneous temperature
measurements taken over time (last 1 hr) by the EAM.
•
Maximum Ambient Temp:
The maximum temperature taken by the EAM since it
began recording data.
•
Minimum Ambient Temp:
The minimum temperature taken by the EAM since it began
recording data.
•
Humidity (e.g. <30%):
The accumulated amount of time (hrs) that the humidity
measured by the EAM stayed in the range specified.
•
Temp (e.g. <=-20°C):
The accumulated amount of time (hrs) that the temperature
measured by the EAM stayed in the range specified.
•
Temp and Humidity (e.g. >40°C and <55%):
The accumulated amount of time (hrs)
that the temperature and humidity measured by the EAM stayed in the ranges
specified.
•
Surge Count:
The number of surge (>500 V/1.2/50 µS) events that have occurred since
the EAM started recording data.
Summary of Contents for 845
Page 10: ...VIII 845 TRANSFORMER PROTECTION SYSTEM INSTRUCTION MANUAL ...
Page 219: ...CHAPTER 4 SETPOINTS SYSTEM 845 TRANSFORMER PROTECTION SYSTEM INSTRUCTION MANUAL 4 91 ...
Page 221: ...CHAPTER 4 SETPOINTS SYSTEM 845 TRANSFORMER PROTECTION SYSTEM INSTRUCTION MANUAL 4 93 ...
Page 222: ...4 94 845 TRANSFORMER PROTECTION SYSTEM INSTRUCTION MANUAL SYSTEM CHAPTER 4 SETPOINTS ...
Page 223: ...CHAPTER 4 SETPOINTS SYSTEM 845 TRANSFORMER PROTECTION SYSTEM INSTRUCTION MANUAL 4 95 ...
Page 224: ...4 96 845 TRANSFORMER PROTECTION SYSTEM INSTRUCTION MANUAL SYSTEM CHAPTER 4 SETPOINTS ...
Page 225: ...CHAPTER 4 SETPOINTS SYSTEM 845 TRANSFORMER PROTECTION SYSTEM INSTRUCTION MANUAL 4 97 ...
Page 226: ...4 98 845 TRANSFORMER PROTECTION SYSTEM INSTRUCTION MANUAL SYSTEM CHAPTER 4 SETPOINTS ...
Page 227: ...CHAPTER 4 SETPOINTS SYSTEM 845 TRANSFORMER PROTECTION SYSTEM INSTRUCTION MANUAL 4 99 ...
Page 396: ...4 268 845 TRANSFORMER PROTECTION SYSTEM INSTRUCTION MANUAL MONITORING CHAPTER 4 SETPOINTS ...
Page 526: ...6 22 845 TRANSFORMER PROTECTION SYSTEM INSTRUCTION MANUAL FLEXELEMENTS CHAPTER 6 METERING ...