Simon XTi Installation Guide 

Content 

Contact information ................................................................................ 1

 

Description ................................................................................................... 1

 

Installation.................................................................................................... 1

 

Connecting hardwired devices........................................................... 2

 

Wiring phone lines.................................................................................... 3

 

Wiring the power transformer............................................................ 4

 

Resetting memory to factory defaults ............................................ 4

 

Programming.............................................................................................. 4

 

Status & Settings screen........................................................................ 5

 

Sensors ......................................................................................................... 7

 

Cleaning the touch screen.................................................................... 9

 

Disposal ......................................................................................................... 9

 

Specifications........................................................................................... 10

 

Regulatory information....................................................................... 10

 

Contact information 

www.utcfireandsecurity.com

 or 

www.interlogix.com

 

For customer support, see 

www.interlogix.com/customer-support

  

GE and the GE monogram are trademarks of the General Electric 
Company and are under license to UTC Fire & Security, 9 Farm 
Springs Road, Farmington, CT 06034-4065 

Copyright © 2012 UTC Fire & Security. All rights reserved. 

Description 

This is the Installation Guide for the Simon XTi system (models 600-
1054-95R-12 and 600-1054-95R-12-CN). 

Table 1: Sensors and recommended sensor groups 

Device Part 

number 

Recommended 
sensor group 

Indoor motion sensor 

60-639-95R, 60-807-95

 b

  15, 17, 18, 20, 28, or 

32  

Entry/exit door 

60-362N-10-319.5 

10 

Interior door 

60-362N-10-319.5 

14 

Door/Window sensor 

60-362N-10-319.5 

13 

Smoke sensor 

TX-6010-01-1 

c

 26 

 

Glassbreak sensor 

60-873-95

 b

 13 

 

Device Part 

number 

Recommended 
sensor group 

4-Button Key fob 

600-1064-95R 

b

 01 

 

 

Simon XT Talking Touch 
Screen 

60-924-3-XT-2WTTS 

b

 

60-924-RF-TS 

 d

 

00, 01, 04, 05, 06, or 
07 

Simon XT Talking 
Touchpad  

60-924-3-XT 

b

 01 

Carbon Monoxide alarm 

TX-6310-01-1

 b

, 600-

6520-95 

b

 

34  

a.

 

Not certified as a primary protection circuit for UL-listed systems 
and is for supplementary use only. 

b.

 

Has not been investigated by UL. 

c.

 

Required for UL-listed residential fire alarm applications. 

d.

 

The TWTTS has been verified for use by ETL. Neither this device 
nor other devices that employ the UTCFS 80 Bit Enhanced 
Protocol have been investigated for use by UL. 

Note

: These sensor groups are only recommendations. The installer should 

choose the correct sensor group for the application. 

Caution: 

Do not use outdoor motion sensors for intrusion 

protection. 

Installation 

Panel location 

Locate the panel where alarm sounds can be heard and where 
the panel will be easily accessible for operation. Do not install the 
panel near a window or door where it can be reached easily by an 
intruder. 

Summary of Contents for 600-1064-95R b

Page 1: ...62N 10 319 5 10 Interior door 60 362N 10 319 5 14 Door Window sensor 60 362N 10 319 5 13 Smoke sensor TX 6010 01 1 c 26 Glassbreak sensor 60 873 95b 13 Device Part number Recommended sensor group 4 Bu...

Page 2: ...ecure the mounting screws provided to the locations on the wall marked in step 6 Do not tighten the screws Leave enough clearance to mount the mounting plate Note Use wall anchors if no studs are pres...

Page 3: ...he use of multiple devices on a single phone line simultaneously For DSL environments connect the panel line in jack to an available phone jack on the premises You might also need an inline filter to...

Page 4: ...et is not controlled by a switch or that it is not part of a ground fault circuit interrupt GFCI Note For Canadian installations plug the transformer into the wall outlet 1 Remove the center screw fro...

Page 5: ...es that you need to close the front door Correct the problem as indicated or press Bypass You will see the arming countdown message at the bottom of the screen You can touch Cancel and enter your code...

Page 6: ...ions Opening report Closing report Force armed report AC power failure report Panel low battery report Sensor alarm restoral report 24 hour sensor tamper Supervisory tamper report No usage report Swin...

Page 7: ...o six digits long Sensors These instructions describe how to add learn sensors touchpads and other system devices into panel memory The panel recognizes a sensor when you press a sensor program icon p...

Page 8: ...ted and whenever a sensor related problem occurs Note While the sensor test is a valuable installation and service tool it only tests sensor operation for the current conditions You should perform a s...

Page 9: ...good sensor functions contact UTC Fire Security for repair or replacement of the problem sensor Sensor Testing Notes Conduct sensor test in all possible environmental conditions For example interior d...

Page 10: ...s turned on Auto arm set to on Siren timeout set to 5 minutes or more Trouble beeps set to on RF jam detect set to on Hardwired siren supervision set to on Exit extension set to off Quick exit set to...

Page 11: ...UL Canada listed installations Canadian standards CSA certified accessories Standard Class 2 9 VAC 30 VA power transformer UTC Fire Security model 22 153 CN or Standard Class 2 9 VAC 25 VA UTC Fire Se...

Reviews: