Chapter 4
Programming
31
Entering and exiting the system menu
To enter the system menu, press either the scroll up/down or
Enter
buttons in the upper right of the panel.
Press the
STATUS
button to exit a menu or option edit mode and navigate up one level. Pressing the
STATUS
button while in the top menu level exits the system menu level. The panel automatically exits the system menu
after a few seconds of inactivity if no access code has been entered yet. After an access code has been entered
to access a code-protected area of the system menu, the timeout is 4 minutes.
Table 7.
Simon XT panel keys and features
Control
Description
Piezo siren
The piezo siren makes alarm beeps and status beeps. Fire and intrusion alarm beeps are always played
at high volume, while the volume of status beeps (such as trouble or chime beeps, entry and exit delay
beeps, or auxiliary alarm beeps) is programmable.
LCD display
The LCD module has a 2 x 16 character array that displays a variety of phrases and icons.
DOORS + WINDOWS
Press to arm perimeter sensors.
MOTIONS
Press to arm interior sensors.
DISARM
Press to turn off intrusion/burglary protection for your system. Only intrusion/burglary sensors such as
doors, windows, and motion sensors are disarmed. Environmental sensors, such as smoke and carbon
monoxide, stay active at all times.
STATUS
Press to determine system status.
SILENT
Press to silence exit beeps when arming.
BYPASS
Press to bypass a sensor.
Police
Press and hold the
Police
button
for two seconds (or press twice quickly) to call the central monitoring
station and notify them of a nonmedical call for help.
Emergency
Press and hold the
Emergency
button
for two seconds (or press twice quickly) to call the central
monitoring station and notify them of a nonmedical call for help.
Fire
Press and hold the
Fire
button
for two seconds (or press twice quickly) to call the central monitoring
station and notify them of a nonmedical call for help.
Microphone
Used to communicate with central monitoring station after an alarm.
Scroll up/scroll down
Press to scroll through lists of similar items.
Enter
Press to select a particular menu item or commit to memory a menu item that has just been
programmed.
Numeric keypad
Twelve-key telephone-type keypad (0 through 9, *, #) for entering access codes or other numerical
data.
Speaker
Provides voice output and sounds key beeps. The panel speaks arming level changes, system status,
and voice chime sensor trips. The panel voice is also used for voice reporting and remote phone control.
Door
Covers the lower panel.
*
Lights on.
#
Lights off.