DFR PS1 

 

Safety Instructions 

Please be familiar with all information in this manual prior to installation and 
operation.  

 

ALL ELECTRICAL INSTALLATIONS MUST MEET LOCAL AND NATIONAL WIRING 
CODES AND SHOULD BE PERFORMED BY A QUALIFIED ELECTRICIAN. 

1.

 

Keep these instructions. 

2.

 

Heed all warnings. 

3.

 

Follow all instructions. 

 

ENVIRONMENT 

1.

 

Do not use this apparatus near water. 

2.

 

Do not block any ventilation openings. Install in accordance with the 

manufacturer's instructions. 

3.

 

To reduce the risk of fire or electric shock, do not expose this appliance to rain or 

moisture. 

4.

 

Do not install near any heat sources such as radiators, heat registers, stoves, or 

other apparatus (Including amplifiers) that produce heat. 

5.

 

The building installation is considered as providing Short-circuit backup protection 

6.

 

Unplug this apparatus during lightning storms or when unused for long periods of 

time. 

7.

 

Apparatus shall not be exposed to dripping or splashing and no objects filled with 

liquids, shall be placed on the apparatus. 

 

CONNECTION TO AC OUTLET 

The power supply should be operated only from a standard outlet with proper 
grounding connection. 
CAUTION! PLUG REPLACEMENT SHOULD BE DONE BY A QUALIFIED ELECTRICIAN. 
PLEASE ENSURE PROPER POLARITY OF THE CONNECTIONS. 
 
Do not use extension cord unless absolutely necessary. If an extension cord must be 
used, make sure the extension cord wire size should be MINIMUM 12AWG, 20A. 
  

FUSE REPLACEMENT 

Ensure properly rated fuse (250V, 4A) is used in each of the module and should be 
replaced with authorized device.  
 

DIS-ASSEMBLY AND REPAIR 

Only use attachments/accessories specified by the manufacturer. 
The power supply should be disassembled or repaired by a qualified technician. 
Incorrect reassemble or repair may result in a risk of electric shock of fire which may 
result in personal injury and property damage. 
 
    WEEE statement: Please do not throw electronic device     

Summary of Contents for PS1

Page 1: ...GE Security P N 1069699 REV 01 00 ISS 16JUN10 DFR Card Cage Rack and PS1 Power supply Unit Installation Guide ...

Page 2: ... latest product information contact your local supplier or visit us online at www gesecurity com FCC compliance This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equ...

Page 3: ...DFR PS1 i Content Safety Instructions 1 Overview 2 Features 2 Model Numbers 4 Hardware 5 Front and Rear Panel 5 LED Indicators 6 Application Drawing 7 TROUBLESHOOTING 9 Specifications 10 ...

Page 4: ......

Page 5: ...r when unused for long periods of time 7 Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids shall be placed on the apparatus CONNECTION TO AC OUTLET The power supply should be operated only from a standard outlet with proper grounding connection CAUTION PLUG REPLACEMENT SHOULD BE DONE BY A QUALIFIED ELECTRICIAN PLEASE ENSURE PROPER POLARITY OF THE CONNECTION...

Page 6: ...e alarm activates a buzzer built into the unit when the power supply is short circuit Front Panel Controls and Indicators The PS1 front panel contains DC power and a RESET switch The RESET switch is used to disable the alarm and reset the PSU Power Supply Redundancy The PS1 Internal Rack Power Supply is supplied with the DFR Card Cage Rack If power redundancy is required a second PS1 can be instal...

Page 7: ...redundant supply installed Front panel indicator and MUTE switch AC power cord supplied Network management system for rack communications o Status monitoring and operational management o Operational level determination and access control o Network ready for health and connection monitoring ...

Page 8: ...4 DFR PS1 Model Numbers Model Number Descriptions DFR Rack chassis only PS1 Power supply unit ...

Page 9: ...DFR PS1 5 Hardware Front and Rear Panel Figure 2 Front and Rear Panels for the DFR PS1 FRONT PANEL REAR PANEL a Lock b AC Outlet c Fuse Holder d Power switch e Positioning pin a b c d e ...

Page 10: ... failure Reset Button RST a Press this button shortly less than 5 seconds will make the internal alarm buzzer silent upon recognition of the fault b Press and hold the button for more than 5 seconds the PSU will reset the unit to default setting and resume supplying the load when the fault is cleared PS1 can be controlled by NMS For the details please refer to the NMS User Guide ...

Page 11: ...DFR PS1 7 Application Drawing Figure 3 Front and rear view of DFR DFR PS1 and DFV Series ...

Page 12: ...FROM THE PS1 POWER SUPPLY UNIT BACK PLANE The back plane of the rack is for the purpose of distributing voltage to the plug in modules and communication with NETC and plug in module A 10 pin connector is provided from the back plane for each module slot in the rack supplying 12VDC and data exchange by using RS485 PLUG IN MODULES Plug in modules can be installed into a DFR standard 19 485mm chassis...

Page 13: ...connected to its mating connector on the back plane and located at slots 15 17 The optional secondary power supply should be located at slot 12 14 c All Plug in modules should be firmly seated into their respective 10 pin back plane mating connectors If the above conditions have been met the rack should be replaced and returned C Should the power LED on an individual plug in fail to light check th...

Page 14: ...250V Slow blow Fuse Size 5x20mm located in pull out tray on back panel Connectors Power input Recessed IEC 320 3 pin male Cable supplied Mechanical Height 158 4 mm Width 75 mm Depth 204 5 mm Weight 1 57kg Construction Aluminum Finish Black semi gloss paint Mounting Four Captive screw Environmental Operating Temperature 20 C to 60 C Operating Relative Humidity 20 to 90 non condensing Storage Temper...

Reviews: