background image

1

,QVWDOODWLRQ,QVWUXFWLRQV

*(6HFXULW\

'

ZZZ*(6HFXULW\FRP

Product Summary

The freeze sensor detects low temperature conditions 
which may indicate furnace failure. The sensor contains 
a bimetallic thermal switch connected to a built-in trans-
mitter. When the surrounding temperature drops to 
approximately 41°F (5°C), the sensor transmits an alarm 
signal. When the surrounding temperature rises to 50°F 
(10°C), the sensor transmits a restore signal.

Tools and Equipment Needed

Slotted screwdriver

Installation Guidelines

Do...

program and test the sensor 

before

 mounting it.

install the transmitter within 100 feet (30.5 m) of the 
control panel. Although the transmitter has an open-
air range of 500 feet (152 m), the effective indoor 
range may be less.

install the sensor in an area more likely to become 
cold before other areas in the building; placing the 
sensor in such an area ensures early warning.

install the sensor on an interior wall near a continuous 
air flow.

Do not...

install the sensor in the same room as a furnace or 
other heat source that stays warm after furnace failure.

install the sensor on an outside wall or basement floor.

install the sensor in an area with excessive metal or 
electrical wiring.

install the sensor in areas with excessive moisture.

install the sensor where temperatures exceed the sen-
sor’s operating limits of 10° to 120°F (-12° to 49°C).

Programming

The following steps provide a general guideline for pro-
gramming (learning) the freeze sensor into panel mem-
ory. Refer to specific panel 

installation instructions 

for 

complete programming details.

Programming for Simon

®

 Panels:

1. Set your control panel to 

Program 

mode.

2. Proceed to 

Learn Sensors 

menu

.

3. Remove the sensor’s outer cover by pressing the cover 

release button located on the end of the sensor.

4. Press and hold the plastic tab marked 

Press to Pro-

gram 

until the control panel confirms programming.

5. Replace the sensor’s outer cover.

6. Select sensor group and sensor number assignments.

7. At the panel, exit 

Program 

mode.

Programming all other GE Panels:

1. Set your control panel to 

Program 

mode.

2. Proceed to 

Learn Sensors 

menu

.

3. Select sensor group and sensor number assignments.

4. Remove the sensor’s outer cover by pressing the cover 

release button located on the end of the sensor.

5. Press and hold the plastic tab marked 

Press to Pro-

gram 

until the control panel confirms programming.

6. Replace the sensor’s outer cover.

7. At the panel, exit 

Program 

mode.

Note

Refer to specific Quick Bridge

® 

Loop Receiver documents 

for additional programming information.

Testing

The following steps provide a general guideline for test-
ing the freeze sensor. Refer to specific panel 

installation 

instructions 

for complete testing details.

1. Set your control panel to 

Sensor Test 

mode.

2. Trip the sensor by pressing and holding the plastic tab 

marked 

Press to Program 

for at least one second.

3. Listen for appropriate sirens as described in the panel 

installation instructions. The sirens indicate the num-
ber of signals the panel has received from the sensor.

Installation

This section describes how to install the sensor after suc-
cessful programming and testing.

1. Secure sensor base to a clean, dry, nonporous mount-

ing surface using the double-sided tape.

Or 

follow steps 2-4 to secure sensor base with screws.

2. Remove the sensor’s cover by pressing the cover 

release button on the end of the sensor.

3. Remove batteries and access the mounting holes.

4. Use the included screws to secure sensor base at each 

mounting hole location (see Figure 1). Remember to 
use an achor if mounting sensor on drywall or plaster.

Note

Mounting Hole #2 may not be accessible on all models.

5. Install the AAA batteries and replace cover.

MOUNTING HOLE #1

9255G02A.DSF

MOUNTING HOLE #2

Figure 1.  Mounting Hole Locations

6$:/HDUQ0RGH)UHH]H

6HQVRU

Document No. 466-1541Rev. E

September 2004

Reviews: