B-14
B90 Low Impedance Bus Differential System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
07EC
...Repeated for IEC103 Command 28
07F0
...Repeated for IEC103 Command 29
07F4
...Repeated for IEC103 Command 30
07F8
...Repeated for IEC103 Command 31
07FC
...Repeated for IEC103 Command 32
FlexStates (Read Only)
0900
FlexState Bits (16 items)
0 to 65535
---
1
F001
0
Element States (Read Only)
1000
Element Operate States (64 items)
0 to 65535
---
1
F502
0
User Displays Actuals (Read Only)
1080
Formatted user-definable displays (16 items)
---
---
---
F200
(none)
Modbus User Map Actuals (Read Only)
1200
User Map Values (256 items)
0 to 65535
---
1
F001
0
Element Targets (Read Only)
14E0
Target Sequence
0 to 65535
---
1
F001
0
14E1
Number of Targets
0 to 65535
---
1
F001
0
Element Targets (Read/Write)
14E2
Target to Read
0 to 65535
---
1
F001
0
Element Targets (Read Only)
14E3
Target Message
---
---
---
F200
“.”
Contact Input/Output States (Read Only)
1500
Contact Input States (6 items)
0 to 65535
---
1
F500
0
1508
Virtual Input States (8 items)
0 to 65535
---
1
F500
0
1510
Contact Output States (4 items)
0 to 65535
---
1
F500
0
1518
Contact Output Current States (4 items)
0 to 65535
---
1
F500
0
1520
Contact Output Voltage States (4 items)
0 to 65535
---
1
F500
0
1528
Virtual Output States (6 items)
0 to 65535
---
1
F500
0
1530
Contact Output Detectors (4 items)
0 to 65535
---
1
F500
0
Input/Output States (Read Only)
1540
Remote Device States (2 items)
0 to 65535
---
1
F500
0
1542
Remote Input States (4 items)
0 to 65535
---
1
F500
0
1550
Remote Devices Online
0 to 1
---
1
F126
0 (No)
1551
Remote Double-Point Status Input 1 State
0 to 3
---
1
F605
3 (Bad)
1552
Remote Double-Point Status Input 2 State
0 to 3
---
1
F605
3 (Bad)
1553
Remote Double-Point Status Input 3 State
0 to 3
---
1
F605
3 (Bad)
1554
Remote Double-Point Status Input 4 State
0 to 3
---
1
F605
3 (Bad)
1555
Remote Double-Point Status Input 5 State
0 to 3
---
1
F605
3 (Bad)
Platform Direct Input/Output States (Read Only)
15C0
Direct Input States (6 items)
0 to 65535
---
1
F500
0
15C8
Direct Outputs Average Message Return Time 1
0 to 65535
ms
1
F001
0
15C9
Direct Outputs Average Message Return Time 2
0 to 65535
ms
1
F001
0
15CA
Direct Inputs/Outputs Unreturned Message Count - Ch. 1
0 to 65535
---
1
F001
0
15CB
Direct Inputs/Outputs Unreturned Message Count - Ch. 2
0 to 65535
---
1
F001
0
15D0
Direct Device States
0 to 65535
---
1
F500
0
15D1
Reserved
0 to 65535
---
1
F001
0
15D2
Direct Inputs/Outputs CRC Fail Count 1
0 to 65535
---
1
F001
0
15D3
Direct Inputs/Outputs CRC Fail Count 2
0 to 65535
---
1
F001
0
Ethernet Fibre Channel Status (Read/Write)
1610
Ethernet Primary Fibre Channel Status
0 to 2
---
1
F134
0 (Fail)
1611
Ethernet Secondary Fibre Channel Status
0 to 2
---
1
F134
0 (Fail)
1612
Ethernet Tertiary Fibre Channel Status
0 to 2
---
1
F134
0 (Fail)
Bus Differential Actual Values (Read Only) (4 Modules)
21D0
Bus Zone 1 Differential Magnitude
0 to 999999.999
A
0.001
F060
0
21D4
Bus Zone 1 Differential Angle
-359.9 to 0
degrees
0.1
F002
0
Table B–10: MODBUS MEMORY MAP (Sheet 6 of 52)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for B90
Page 10: ...x B90 Low Impedance Bus Differential System GE Multilin TABLE OF CONTENTS ...
Page 284: ...5 166 B90 Low Impedance Bus Differential System GE Multilin 5 8 TESTING 5 SETTINGS 5 ...
Page 334: ...10 8 B90 Low Impedance Bus Differential System GE Multilin 10 2 BATTERIES 10 MAINTENANCE 10 ...
Page 338: ...A 4 B90 Low Impedance Bus Differential System GE Multilin A 1 PARAMETER LISTS APPENDIX A A ...
Page 460: ...C 30 B90 Low Impedance Bus Differential System GE Multilin C 7 LOGICAL NODES APPENDIX C C ...
Page 476: ...E 10 B90 Low Impedance Bus Differential System GE Multilin E 1 IEC 60870 5 104 APPENDIX E E ...
Page 502: ...viii B90 Low Impedance Bus Differential System GE Multilin INDEX ...